{lead}
{name}
  • {name}
  • 日本語
  • English (Global)
  • English (Asia Pacific)
  • 简体中文
  • 繁體中文
  • 한국어
Panasonic Industry / Automation Controls
Panasonic Industry / Automation Controls

Digital Fiber Sensor FX-250

  • Basic Information

  • Order guide

  • Option

  • Specifications

  • Dimensions

  • Circuit / Wiring

  • List of fibers

  • Cautions For Use

Basic Information

“Ease of use” evolves to the next generation.

Order guide

Amplifier

AppearanceModel No.Emitting elemenOutput
fx-250
FX-251-C2Red LEDNPN open-collector transistor
FX-251P-C2PNP open-collector transistor

End plates

End plates are not supplied with the amplifier. Please order them separately when the amplifiers are mounted in cascade.

AppearanceModel No.Description
MS-DIN-EWhen an amplifier moves depending on the way it is installed on a DIN rail, these end plates clamp amplifiers into place on both sides. Make sure to use end plates when connecting multiple amplifiers together.
[Two pcs. per set]

Option

DesignationModel No.Description
Amplifier mounting bracketMS-DIN-2Mounting bracket for amplifier

Amplifier mounting bracket

MS-DIN-2

MS-DIN-2

Others

Please refer to "Fiber Options" for details of fiber lenses and other options.

Specifications

TypeNPN output typePNP output type
Model No.FX-251-C2FX-251P-C2
Applicable regulationsCE Marking (EMC Directive, RoHS Directive)
Supply voltage12 to 24 V DC ±10% Ripple P-P 10% or less
Power consumption960 mW or less (current consumption 40 mA or less at 24 V supply voltage)
OutputNPN open-collector transistor
・Maximum sink current: 100 mA
  ・Applied voltage: 30 V DC or less (between output and 0 V)
  ・Residual voltage: 2 V or less (at maximum sink current)
PNP open-collector transistor
・Maximum source current: 100 mA
  ・Applied voltage: 30 V DC or less (between output and +V)
  ・Residual voltage: 2 V or less (at maximum source current)
 Output operationSwitchable either Light-ON or Dark-ON
 Short-circuit protectionIncorporated
Response timeH-SPD: 35 μs or less, FAST: 60 μs or less, STD: 250 μs or less, LONG: 2 ms or less, H-PWR: 24 ms or less, selectable
Output indicatorOrange LED turns on when output is ON.
Sensitivity setting2-point teaching / Limit teaching / Full-auto teaching / Manual adjustment
Threshold value adjustment functionIncorporated
Incident light intensity adjustment functionIncorporated, max. 100 steps
Incident light intensity display rangeH-SPD / FAST / STD: 0 to 4,000, LONG / H-PWR: 0 to 9,999
Digital displayWhite organic EL display
Various settingsShift amount setting (percentage, fixed value), display style setting, display inversion setting, ECO setting, zero-set function
Timer functionOFF-delay timer / ON-delay timer / One-shot timer, switchable either effective or ineffective
(setting range: 1 to 9,999 ms in 1-ms increments)
Interference prevention functionIncorporated (4 selectable frequencies) (Note 2)
Environmental resistanceProtectionIP40 (IEC)
Ambient temperature-10 to +55 ℃ +14 to +131 ℉ (If 4 to 7 units close mounting: -10 to +50 ℃ +14 to +122 ℉ or if 8 to 16 units close mounting: -10 to +45 ℃ +14 to +113 ℉) (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉
Ambient humidity35 to 85% RH, Storage: 35 to 85% RH
Ambient illuminanceIncandescent light: 10,000 ℓx or less at the light-receiving face
Voltage withstandability1,000 V AC for one min. between all supply terminals connected together and enclosure (Note 3)
Insulation resistance20 MΩ or more, with 250 V DC megger between all supply terminals connected together and enclosure (Note 3)
Vibration resistance10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (100 m/s2 max.) in X, Y and Z directions for two hours each (without power supply)
Shock resistance98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each (without power supply)
Emitting element
(modulation type)
Red LED (Peak emission wavelength: 660 nm 0.026 mil)
MaterialEnclosure, cover, switch: Polycarbonate
Cable0.2 mm2 3-core cabtyre cable, 2 m 6.562 ft long
Cable extensionExtension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
(however, supply voltage 24 V DC or more)
WeightNet weight: 55 g approx., Gross weight: 80 g approx.

Notes:
1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.

2) When the interference prevention function is used, set different light emission frequencies in the amplifiers for interference prevention.

3) The indicated voltage withstandability and insulation resistance values apply to the amplifier unit.

Dimensions

  • Unit: mm in

FX-251-C2 FX-251P-C2

Amplifier

fx-250_size

MS-DIN-2

Amplifier mounting bracket (Optional)

MS-DIN-2

Material: Cold rolled carbon steel (SPCC) (Uni-chrome plated)

MS-DIN-E

End plate (Optional)

MS-DIN-E

Material: Polycarbonate

Circuit / Wiring

FX-251-C2

I/O circuit diagram

I/O circuit diagram

Symbols…
D1:Reverse supply polarity protection diode
D2:Reverse output polarity protection diode
ZD:Surge absorption zener diode
Tr:NPN output transistor

Wiring diagram

Wiring diagram

FX-251P-C2

I/O circuit diagram

I/O circuit diagram

Symbols…
D1:Reverse supply polarity protection diode
D2:Reverse output polarity protection diode
ZD:Surge absorption zener diode
Tr:PNP output transistor

Wiring diagram

Wiring diagram

List of fibers

Response time of FX-250 series is as follows.

ModeSTDH-PWRLONGFASTH-SPD
Response time250 μs or less24 ms or less2 ms or less60 μs or less35 μs or less

List of fiber

Sensing characteristic

Sensing characteristics can be downloaded at catalog download site.
Please contact our office if not listed here.

Square Head Fiber

■Thru-beam type(one pair set)

TypeModel No.Sensing range(mm in)(Note1)
STDH-PWRLONGFASTH-SPD
Square headM3FT-R31270 10.6301,000 39.370440 17.323160 6.29955 2.165
M4FT-R43720 28.4363,000 118.1101,100 43.307430 16.929130 5.118
FT-R41W800 31.4963,200 125.9841,400 55.118460 18.110130 5.906
FT-R42W2,200 86.6143,600 141.732
(Note2)
3,500 137.7951,300 51.181460 18.110
FT-R44Y720 28.3463,000 118.1101,100 43.307430 16.929130 5.118
M6FT-R60Y2,100 82.6773,600 141.732
(Note2)
3,600 141.732
(Note2)
1,260 49.606400 15.748

Note1:Note that sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note2:The fiber cable length practically limits the sensing range.

■Reflective type

TypeModel No.Sensing range(mm in) (Note1)(Note2)
STDH-PWRLONGFASTH-SPD
Square headM3FD-R35G130 5.118455 17.913185 7.28365 2.55920 0.787
FD-R32EG45 1.772170 6.69392 3.62230 1.1819 0.354
FD-R34EG38 1.496130 5.11870 2.75623 0.9067 0.276
FD-R33EG19 0.74884 3.30733 1.29911 0.4333 0.118
M4FD-R41210 8.268710 27.953320 12.598100 3.93734 1.339
M6FD-R61Y280 11.024990 38.976435 17.126160 6.29950 1.969

Note1:Note that sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note2:The sensing range is specified for white non-glossy paper.

For details of Square Head Fiber, refer to product information page.
>>Go to "Square Head Fiber"

Super Quality

■Thru-beam type (one pair set)

TypeModel No.Sensing range(mm in)
STDH-PWRLONGFASTH-SPD
ThreadedM3FT-30400 15.7481,350 53.150650 25.591210 8.26875 2.953
M4FT-401,200 47.2443,600 141.732 (Note)1,700 66.929530 20.866190 7.480
Cylindricalø1.5FT-S20400 15.7481,350 53.150650 25.591210 8.26875 2.953
ø3FT-S301,200 47.2443,600 141.732 (Note)1,700 66.929530 20.866190 7.480

Note:The fiber cable length practically limits the sensing range.

■Reflective type

TypeModel No.Sensing range(mm in) (Note1)
STDH-PWRLONGFASTH-SPD
ThreadedM3FD-30160 6.299600 23.622250 9.84380 3.15025 0.984
M4FD-40160 6.299600 23.622250 9.84380 3.15025 0.984
M6FD-60520 20.4721,550 61.024740 29.134260 10.23690 3.543
Cylindricalø3FD-S30160 6.299600 23.622250 9.84380 3.15025 0.984

Note1:The sensing range is specified for white non-glossy paper.

For details of Super Quality Fiber, refer to product information page.
>>Go to "Super Quality Fiber"

Threaded Type

■Thru-beam type (one pair set)

TypeModel No.Sensing range(mm in) (Note1)
STDH-PWRLONGFASTH-SPD
ThreadedM3FT-31315 12.4021,350 53.150550 21.654210 8.26870 2.576
FT-31W260 10.236990 38.976440 17.323150 5.90653 2.087
FT-323,000 118.1103,600 141.732
(Note2)
3,600 141.732
(Note2)
1,600 62.992580 22.835
M4 FT-431,400 55.1183,600 141.732
(Note2)
2,100 82.677770 30.315240 9.449
FT-421,130 44.4883,600 141.732
(Note2)
1,600 62.992530 20.866190 7.480
FT-42W800 31.4963,300 129.9211,400 55.118490 19.291160 6.299
FT-45X1,200 47.2441,600 62.992
(Note2)
1,600 62.992
(Note2)
630 24.803200 7.874
ElbowFT-R40930 36.6143,600 141.732
(Note2)
1,500 59.055500 19.685160 6.299
M14Long rangeFT-14019,600 771.654
(Note2)
19,600 771.654
(Note2)
19,600 771.654
(Note2)
16,000 629.9216,300 248.031

Note1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note2:The fiber cable length practically limits the sensing range.

■Reflective type

TypeModel No.Sensing range(mm in) (Note1)(Note2)
STDH-PWRLONGFASTH-SPD
ThreadedM3 FD-31125 4.921515 20.276220 8.66180 3.15025 0.984
FD-31W80 3.150330 12.992140 5.51245 1.77212 0.472
FD-32G200 7.874650 25.591270 10.63095 3.74027 1.063
FD-32GX200 7.874630 24.803360 14.173100 3.93730 1.181
FD-34G90 3.543330 12.992135 5.30549 1.92915 0.591
Ultra-small diameterFD-EG3048 1.890170 6.693110 4.33130 1.1819 0.354
FD-EG3120 0.78785 3.34635 1.37812 0.4723.5 0.138
M4FD-41125 4.921515 20.276220 8.66180 3.15025 0.984
FD-41W270 10.630900 35.433430 16.929150 5.90645 1.772
FD-42G200 7.874650 25.591270 10.63095 3.74027 1.063
FD-42GW
(Discontinued products)
150 5.906670 26.378280 11.02490 3.54325 0.984
M6 FD-62520 20.4721,500 59.055940 37.008340 13.386110 4.331
FD-61450 17.7171,400 55.118670 26.378200 7.87470 2.756
FD-61W270 10.630900 35.433430 16.929150 5.90645 1.772
FD-64X280 11.024670 26.378410 16.142160 6.29950 1.969
ElbowFD-R60290 11.4171,100 43.307550 21.654190 7.48065 2.559

Note1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note2:The sensing range is specified for white non-glossy paper.

For details of Threaded Type Fiber, refer to product information page.
>>Go to "Threaded Type Fiber"

Cylindrical Type

■Thru-beam type (one pair set)

TypeModel No.Sensing range(mm in) (Note1)
STDH-PWRLONGFASTH-SPD
Cylindricalø1FT-S1190 3.543350 13.780160 6.29960 2.36219 0.748
ø1.5FT-S21315 12.4021,350 53.150550 21.654210 8.26870 2.756
FT-S21W260 10.236990 38.976440 17.323150 5.90653 2.087
FT-S22450 17.7171,500 59.055730 28.740250 9.84390 3.543
ø2.5FT-S323,100 122.0473,600 141.732
(Note2)
3,600 141.732
(Note2)
1,800 70.866600 23.622
ø3FT-S31W800 31.4963,300 129.9211,400 55.118490 19.291160 6.299
Ultra-small
diameter
ø3FT-E1315 0.59152 2.04724 0.9458 0.3152 0.079
FT-E2375 2.953270 10.630125 4.92142 1.65413 0.512
Side-viewø4FT-V403,500 137.7953,600 141.732
(Note2)
3,600 141.732
(Note2)
2,400 94.488850 33.465

Note1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note2:The fiber cable length practically limits the sensing range.

■Reflective type

TypeModel No.Sensing range(mm in) (Note1)(Note2)
STDH-PWRLONGFASTH-SPD
Cylindricalø1.5FD-S2346 1.811130 5.11865 2.55920 0.7877 0.276
ø3FD-S32420 16.5351,200 47.244660 25.984220 8.66175 2.953
FD-S32W270 10.630900 35.433430 16.929150 5.90645 1.772
FD-S31125 4.921515 20.276220 8.66180 3.15025 0.984
FD-S33GW150 5.906670 26.378280 11.02490 3.54325 0.984
FD-S34G90 3.543330 12.992135 5.30549 1,92915 0.591
Ultra-small
diameter
ø1.5FD-E1312 0.47250 1.96925 0.9847 0.2762 0.079
ø3FD-E2355 2.165170 6.69380 3.15030 1.1819 0.354

Note1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note2:The sensing range is specified for white non-glossy paper.

For details of Cylindrical Type Fiber, refer to product information page.
>>Go to "Cylindrical Type Fiber"

Sleeve

■Thru-beam type (one pair set)

TypeModel No.Sensing range(mm in) (Note1)
STDH-PWRLONGFASTH-SPD
ThreadedM3FT-31S315 12.4021,220 48.031550 21.654195 7.67763 2.480
M4FT-42S1,130 44.4883,600 141.732
(Note2)
1,600 62.992530 20.866190 7.480
CylindricalUltra-small diameterø3FT-E1315 0.59152 2.04724 0.9458 0.3152 0.079
FT-E2375 2.953270 10.630125 4.92142 1.65413 0.512
Side-viewø2FT-V23450 17.7171,800 70.866880 34.646280 11.02490 3.543
FT-V25240 9.449900 35.433480 18.898140 5.51245 1.772
FT-V24W110 4.331380 14.961200 7.87460 2.36220 0.787
ø2.5FT-V30680 26.7722,200 86.6141,000 39.370340 13.386100 3.937

Note1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note2:The fiber cable length practically limits the sensing range.

■Reflective type

TypeModel No.Sensing range(mm in) (Note1)(Note2)
STDH-PWRLONGFASTH-SPD
ThreadedUltra-small diameterM3FD-EG30S50 1,969170 6.69380 3.15030 1.1819 0.354
M4FD-41S125 4.921515 20.276220 8.66180 3.15025 0.984
FD-41SW80 3.150330 12.992140 5.51245 1.77212 0.472
M6FD-61S420 16.5351,200 47.244660 25.984220 8.66175 2.953
CylindricalUltra-small diameterø1.5FD-E1312 0.47250 1.96925 0.9847 0.2762 0.079
ø3FD-E2355 2.165170 6.69380 3.15030 1.1819 0.354
Side-viewø3FD-V3065 2.559240 9.449120 4.72435 1.37814 0.551
FD-V30W20 0.78780 3.15030 1.18110 0.3942 0.079
ø5FD-V50120 4.724370 14.567210 8.26875 2.95325 0.984

Note1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note2:The sensing range is specified for white non-glossy paper.

For details of Sleeve Fiber, refer to product information page.
>>Go to "Sleeve Fiber"

Flat Type

■Thru-beam type (one pair set)

TypeModel No.Sensing range(mm in) (Note1)
STDH-PWRLONGFASTH-SPD
Flat FT-Z30H3,500 137.7953,600 141.732
(Note2)
3,600 141.732
(Note2)
2,600 102.362810 31.890
FT-Z30HW3,500 137.7953,600 141.732
(Note2)
3,600 141.732
(Note2)
2,600 102.362810 31.890
FT-Z30E3,500 137.7953,600 141.732
(Note2)
3,600 141.732
(Note2)
2,400 94.488740 29.134
FT-Z30EW3,400 133.8583,600 141.732
(Note2)
3,600 141.732
(Note2)
2,000 78.740630 24.803
FT-Z302,100 82.6773,600 141.732
(Note2)
3,600 141.732
(Note2)
1,200 47.244410 16.142
FT-Z30W1,500 59.0553,600 141.732
(Note2)
3,200 125.9841,000 39.370280 11.024
With bossFT-Z20W620 24.4091,600 62.992
(Note2)
1,100 43.307420 16.535130 5.118
FT-Z20HBW260 10.2361,100 43.307570 22.441180 7.08755 2.165
FT-Z40W1,500 59.0553,600 141.732
(Note2)
2,300 90.551900 35.433290 11.417
FT-Z40HBW800 31.4963,300 129.9211,400 55.118490 19.291160 6.299

Note1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note2:The fiber cable length practically limits the sensing range.

■Reflective type

TypeModel No.Sensing range(mm in) (Note1)(Note2)
STDH-PWRLONGFASTH-SPD
FlatWith bossFD-Z20W1 to 65
0.039 to 2.559
260
10.236
130
5.118
2 to 45
0.079 to 1.772
5 to 13
0.197 to 0.512
FD-Z20HBW2 to 85
0.079 to 3.346
1 to 340
39 to 13.386
1 to 180
0.039 to 7.087
2 to 55
0.079 to 2.165
3 to 15
0.118 to 0.591
FD-Z40W190
7.480
790
31.102
390
15.354
1 to 120
0.039 to 4.724
2 to 35
0.079 to 1.378
FD-Z40HBW260
10.236
760
29.921
470
18.504
1 to 160
0.039 to 6.299
2 to 50
0.079 to 1.969

Note1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note2:The sensing range is specified for white non-glossy paper.

For details of Flat Type Fiber, refer to product information page.
>>Go to "Flat Type Fiber"

Narrow Beam

■Thru-beam type (one pair set)

TypeModel No.Sensing range(mm in) (Note1)
STDH-PWRLONGFASTH-SPD
Narrow
beam
 FT-KS403,600 141.732
(Note2)
3,600 141.732
(Note2)
3,600 141.732
(Note2)
3,600 141.732
(Note2)
1,200 47.244
Side viewFT-KV403,600 141.732
(Note2)
3,600 141.732
(Note2)
3,600 141.732
(Note2)
3,100 122.047940 37.008
FT-KV40W3,600 141.732
(Note2)
3,600 141.732
(Note2)
3,600 141.732
(Note2)
3,100 122.047940 37.008
FT-KV26710 27.9532,500 98.4251,200 47.244440 17.323160 6.299
FT-KV26H1630 24.8032,200 86.6141,070 42.126390 15.3541355.315

Note1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note2:The fiber cable length practically limits the sensing range.

■Retroreflective type

TypeModel No.Sensing range(mm in) (Note1)(Note2)
STDH-PWRLONGFASTH-SPD
With polarizing filtersFR-Z50HW100 to 990
3.937 to 38.976
100 to 1,900
3.937 to 74.803
100 to 1,200
3.937 to 47.244
100 to 780
3.937 to 30.709
100 to 490
3.937 to 19.291
Ultra-narrow beamFR-KZ22E15 to 310
0.591 to 12.205
15 to 570
0.591 to 22.441
15 to 410
0.591 to 16.142
15 to 220
0.591 to 8.661
15 to 100
0.591 to 3.937
Narrow
beam
Top
sensing
FR-KZ50H20 to 300
0.787 to 11.811
20 to 1,000
0.787 to 39.370
20 to 400
0.787 to 15.748
20 to 200
0.787 to 7.874
20 to 200
0.787 to 7.874
Side
sensing
FR-KZ50E20 to 300
0.787 to 11.811
20 to 1,000
0.787 to 39.370
20 to 400
0.787 to 15.748
20 to 200
0.787 to 7.874
20 to 200
0.787 to 7.874

Note1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note2:The sensing range is the possible setting range for the attached reflector. The fiber can detect an object less than setting range for the reflector.

■Reflective type

TypeSensing range(mm in) (Note1)(Note2)
STDH-PWRLONGFASTH-SPD
Long rangeFD-Z50HW10 to 650
0.394 to 25.591
10 to 2,500
0.394 to 98.425
10 to 1,000
0.394 to 39.370
10 to 410
0.394 to 16.142
15 to 130
0.591 to 5.118

Note1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note2:The sensing range of reflective type is specified for white non-glossy paper.

For details of Narrow Beam Fiber, refer to product information page.
>>Go to "Narrow Beam Fiber"

Wide Beam

■Thru-beam type (one pair set)

TypeModel No.Sensing range(mm in) (Note1)
STDH-PWRLONGFASTH-SPD
Wide beamFT-A323,600 141.732
(Note2)
3,600 141.732
(Note2)
3,600 141.732
(Note2)
3,600 141.732
(Note2)
2,100 82.677
FT-A32W3,600 141.732
(Note2)
3,600 141.732
(Note2)
3,600 141.732
(Note2)
3,600 141.732
(Note2)
3,000 118.110
FT-A113,600 141.732
(Note2)
3,600 141.732
(Note2)
3,600 141.732
(Note2)
3,600 141.732
(Note2)
1,100 43.307
FT-A11W3,600 141.732
(Note2)
3,600 141.732
(Note2)
3,600 141.732
(Note2)
3,600 141.732
(Note2)
1,300 51.181
ArrayFT-AL05860 33.8582,300 90.5511,500 59.055500 19.685170 6.693

Note1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note2:The fiber cable length practically limits the sensing range.
>>Go to "Wide Beam Fiber"

■Reflective type

TypeModel No.Sensing range(mm in) (Note1)(Note2)
STDH-PWRLONGFASTH-SPD
Wide beamFD-A16200 7.874Cannot use200 7.874140 5.51275 2.953
ArrayFD-AL12270 10.630670 26.378420 16.535150 5.90650 1.969

Note1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note2:The sensing range is specified for white non-glossy paper.

For details of Wide Beam Fiber, refer to product information page.
>>Go to "Wide Beam Fiber"

Convergent Reflective Type

■Reflective type

TypeModel No.Sensing range(mm in) (Note1)(Note2)
STDH-PWRLONGFASTH-SPD
Glass substrate detectionFD-L32H0 to 56
0 to 2.205
0 to 110
0 to 4.331
0 to 74
0 to 2.913
1 to 38
0.039 to 1.496
Cannot use
FD-L30A0 to 43
0 to 1.693
0 to 43
0 to 1.693
0 to 43
0 to 1.693
0 to 42
0 to 1.654
0 to 29
0 to 1.142
FD-L31A4 to 33
0.157 to 1.299
3 to 35
0.118 to 1.378
4 to 33
0.157 to 1.299
4 to 32
0.157 to 1.260
5 to 25
0.197 to 0.984
FD-L24A0 to 23
0 to 0.906
0 to 31
0 to 1.220
0 to 26
0 to 1.024
0 to 22
0 to 0.866
0 to 18
0 to 0.709
FD-L250 to 29
0 to 1.142
0 to 30
0 to 1.181
0 to 30
0 to 1.181
0 to 28
0 to 1.102
2 to 23
0.079 to 0.906
FD-L110 to 9.5
0 to 0.374
0 to 11.5
0 to 0.453
0 to 10
0 to 0.394
0 to 9
0 to 0.354
0 to 8
0 to 0.315
FD-L100 to 5
0 to 0.197
0 to 6
0 to 0.236
0 to 5.5
0 to 0.217
0 to 4.5
0 to 0.177
0 to 4
0 to 0.157
FD-L211.5 to 16
0.059 to 0.630
1 to 19
0.039 to 0.748
1 to 18
0.039 to 0.709
2 to 15
0.079 to 0.591
3 to 12
0.118 to 0.472
FD-L21W3 to 14
0.118 to 0.551
1.5 to 15
0.059 to 0.591
2 to 15
0.079 to 0.591
4 to 14
0.157 to 0.551
6.5 to 10
0.256 to 0.394
General purposeFD-L20H0 to 23
0 to 0.906
0 to 45
0 to 1.772
0 to 32
0 to 1.260
2 to 15
0.079 to 0.591
5 to 9
0.197 to 0.354
Ultla-smallFD-L12W0 to 8
0 to 0.315
0 to 14
0 to 0.551
0 to 12
0 to 0.472
0.5 to 7
0.020 to 0.276
0.5 to 4
0.020 to 0.157
FD-L13H10 to 4
0 to 0.157
0 to 5
0 to 0.197
0 to 4
0 to 0.157
0 to 3.5
0 to 0.138
0 to 2
0 to 0.079

Note1:The sensing range is specified for transparent glass 100 x 100 x t0.7 mm 3.937 × 3.937 × t0.028 in (FD-L32H: R edge, FD-L21 and FD-L21W: t2 mm t0.079 in, FD-L13H1: 50 × 50 × t0.7 mm 1.969 × 1.969 × t0.028 in.) (FD-L20H: white non-glossy paper, FD-L10: silicon wafers 100 x 100 mm 3.937 × 3.937 in).

Note2:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

For details of Convergent Reflective Type Fiber, refer to product information page.
>>Go to "Convergent Reflective Type Fiber"

Retroreflective Type

■Retroreflective type

TypeModel No.Sensing range(mm in) (Note1)(Note2)
STDH-PWRLONGFASTH-SPD
With polarizing filtersFR-Z50HW100 to 990
3.937 to 38.976
100 to 1,900
3.937 to 74.803
100 to 1,200
3.937 to 47.244
100 to 780
3.937 to 30.709
100 to 490
3.937 to 19.291
Ultra-narrow
beam
FR-KZ22E15 to 310
0.591 to 12.205
15 to 570
0.591 to 22.441
15 to 410
0.591 to 16.142
15 to 220
0.591 to 8.661
15 to 100
0.591 to 3.937
Narrow
beam
Top
sensing
FR-KZ50H20 to 300
0.787 to 11.811
20 to 1,000
0.787 to 39.370
20 to 400
0.787 to 15.748
20 to 200
0.787 to 7.874
20 to 200
0.787 to 7.874
Side
sensing
FR-KZ50E20 to 300
0.787 to 11.811
20 to 1,000
0.787 to 39.370
20 to 400
0.787 to 15.748
20 to 200
0.787 to 7.874
20 to 200
0.787 to 7.874

Note1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note2:The sensing range is the possible setting range for the attached reflector. The fiber can detect an object less than setting range for the reflector.

For details of Retroreflective Type Fiber, refer to product information page.
>>Go to "Retroreflective Type Fiber"

Chemical-resistant

■Thru-beam type (one pair set)

TypeModel No.Sensing range(mm in) (Note1)
STDH-PWRLONGFASTH-SPD
Chemical-resistantFT-Z802Y3,100 122.0473,600 141.732
(Note2)
3,600 141.732
(Note2)
1,900 74.803470 18.504
FT-HL80Y
(Discontinued products)
3,600 141.732
(Note2)
3,600 141.732
(Note2)
3,600 141.732
(Note2)
2,300 90.551740 29.134
FT-L80Y3,600 141.732
(Note2)
3,600 141.732
(Note2)
3,600 141.732
(Note2)
2,800 110.236920 36.220
FT-V80Y1,300 51.1813,600 141.732
(Note2)
2,200 86,614800 31,496240 9,449

Note1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note2:The fiber cable length practically limits the sensing range.

■Reflective type

TypeModel No.Sensing range(mm in)(Note1)(Note2)
STDH-PWRLONGFASTH-SPD
Chemical-resistantFD-S60Y320 12.598600 23.622420 16.535200 7.87475 2.953

Note1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending on how the fiber is cut.

Note2:The sensing range is specified for white non-glossy paper.

For details of Chemical-resistant Fiber, refer to product information page.
>>Go to "Chemical-resistant Fiber"

Heat-resistant

■Thru-beam type (one pair set)

TypeHeat-resistant
temp.
Model No.Sensing range(mm in) (Note1)
HYPRU-LGLONGSTDFAST
Heat-resistant350℃FT-H35-M2430 16.9291,200 47.244670 26.378250 9.84380 3.150
FT-H35-M2S6430 16.9291,200 47.244670 26.378250 9.84380 3.150
200℃FT-H20W-M1470 18.5041,600 62.992
(Note2)
840 33.071300 11.81190 3.543
FT-H20-M1540 21.2601,600 62.992
(Note2)
960 37.795330 12.992110 4.331
130℃FT-H13-FM2700 27.5593,300 129.9211,300 51.181410 16.142140 5.512
Heat-resistant (joint)200℃FT-H20-J20-S470 18.5041,600 62.992790 31.102300 11.81190 3.543
FT-H20-J30-S470 18.5041,600 62.992790 31.102300 11.81190 3.543
FT-H20-J50-S470 18.5041,600 62.992790 31.102300 11.81190 3.543
FT-H20-VJ50-S600 23.6222,100 82.677980 38.583390 15.354120 4.724
FT-H20-VJ80-S600 23.6222,100 82.677980 38.583390 15.354120 4.724

Note1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note2:The fiber cable length practically limits the sensing range.

■Reflective type

TypeHeat-resistant
temp.
Model No.Sensing range(mm in) (Note1)(Note2)
STDH-PWRLONGFASTH-SPD
Heat-resistantThreaded350℃FD-H35-M2260 10.236720 28.346460 18.110150 5.90645 1.772
FD-H35-M2S6260 10.236720 28.346460 18.110150 5.90645 1.772
FD-H35-20S260 10.236840 33.071440 17.323140 5.51245 1.772
200℃FD-H20-M1330 12.992840 33.071500 19.685200 7.87455 2.165
FD-H20-21230 9.055770 30.315380 14.961130 5.11845 1.772
130℃FD-H13-FM2350 13.780880 34.646600 23.622200 7.87465 2.559
Glass substrate detection convergent reflective300℃FD-H30-L320 to 17
0 to 0.669
0 to 40
0 to 1.575
0 to 25
0 to 0.984
0 to 12
0 to 0.472
1.5 to 6
0.059 to 0.236
250℃FD-H25-L431.5 to 26
0.059 to 1.024
1 to 31
0.039 to 1.220
1 to 28
0.039 to 1.102
1.5 to 24
0.059 to 0.945
2 to 18
0.079 to 0.709
FD-H25-L455 to 42
0.197 to 1.654
4 to 43.5
0.157 to 1.713
4.5 to 43
0.177 to 1.693
5 to 40
0.197 to 1.575
6.5 to 34
0.256 to 1.339
180℃FD-H18-L310 to 16
0 to 0.630
0 to 60
0 to 2.362
0 to 24
0 to 0.945
0 to 13
0 to 0.512
2 to 6.5
0.079 to 0.256

Note1:The sensing range of reflective type is the value for white non-glossy paper (50 x 50 mm 1.969 × 1.969 in glass substrate for FD-H30-L32 and FD-H18-L31, transparent glass 100 x 100 x t0.7 mm 3.937 × 3.937 × t0.028 in for FD-H25-L43 and FD-H25-L45).

Note2:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

For details of Heat-resistant Fiber, refer to product information page.
>>Go to "Heat-resistant Fiber"

One-Touch Connection System Vacuum-resistant Fibers

■Thru-beam type

TypeModel No.Sensing range (mm in)(Note1)
STDH-PWRLONGFASTH-SPD
Vacuum-
resistant
Thru-beamFT-40V270 10.6301,000 39.370470 18.504160 6.29955 2.165

Note1:Atmospheric side fiber, FT-J9 (optional) is free-cut type.
Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

■Reflective type

TypeModel No.Sensing range(mm in) (Note1)(Note2)
STDH-PWRLONGFASTH-SPD
Vacuum-
resistant
Long range
reflective
FD-KZ50V20 to 200
0.787 to 7.874
5 to 500
0.197 to 19.685
15 to 270
0.591 to 10.630
20 to 120
0.787 to 4.724
20 to 45
0.787 to 1.772
Convergent
reflective
FD-L10V0 to 8
0 to 0.315
0 to 18
0 to 0.709
0 to 10
0 to 0.394
0 to 5.5
0 to 0.217
1.5 to 3
0.059 to 0.118

Note1:The sensing range is the value for transparent glass 100 × 100 × t0.7 mm 3.937 × 3.937 × t0.028 in.

Note2:Atmospheric side fiber, FT-J9 (optional) is free-cut type.
Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

For details of One-Touch Connection System Vacuum-resistant Fibers, refer to product information page.
>>Go to "One-Touch Connection System Vacuum-resistant Fibers"

Vacuum-resistant

■Thru-beam type (one pair set)

TypeModel No.Sensing range(mm in)
STDH-PWRLONGFASTH-SPD
Vacuum-resistantThru-beamFT-H30-M1V-S270 10.6301,000 39.370470 18.504160 6.29955 2.165

■Reflective type

TypeModel No.Sensing range(mm in) (Note1)
STDH-PWRLONGFASTH-SPD
Vacuum-resistantReflectiveFD-H30-KZ1V-S20 to 200
0.787 to 7.874
5 to 500
0.197 to 19.685
15 to 270
0.591 to 10.630
20 to 120
0.787 to 4.724
20 to 45
0.787 to 1.772
Convergent
reflective
FD-H30-L32V-S0 to 8
0 to 0.315
0 to 18
0 to 0.709
0 to 10
0 to 0.394
0 to 5.5
0 to 0.217
1.5 to 3
0.059 to 0.118

Note1:The sensing range of reflective type is the value for transparent glass 100 x 100 x t0.7 mm 3.937 × 3.937 × t0.028 in.

For details of Vacuum-resistant Fiber, refer to product information page.
>>Go to "Vacuum-resistant Fiber"

Special-shaped fiber

Special-shaped fiber

Model No.Sensing range (mm in) (Note)
STDH-PWRLONGFASTH-SPD
Heat-resistant U-shaped typeFT-PK40H15 0.197(fixed)5 0.197(fixed)5 0.197(fixed)5 0.197(fixed)5 0.197(fixed)

Note:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

For details of Special-shaped fiber, refer to product information page.
>>Go to "Special-shaped fiber"

Cautions For Use

  • This website is a guide to select a suitable product. Be sure to read instruction manual of the product prior to its use.
  • Never use this product as a sensing device for personnel protection.
  • In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country.

Wiring

  • Make sure that the power supply is OFF while adding or removing the amplifiers.
  • Note that if a voltage exceeding the rated range is applied, or if an AC power supply is directly connected, the product may get burnt or damaged.
  • Note that short-circuit of the load or wrong wiring may burn or damage the product.
  • Do not run the wires together with high-voltage lines or power lines, or put them in the same raceway. This can cause malfunction due to induction.
  • Verify that the supply voltage variation is within the rating.
  • If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground.
  • In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity of this product, connect the frame ground (F.G.) terminal of the equipment to an actual ground.

Others

  • This product has been developed / produced for industrial use only.
  • The specification may not be satisfied in a strong magnetic field.
  • Do not use during the initial transient time (the following time) after the power supply is switched ON.
    H-SPD, FAST, STD: 0.5 sec., LONG, H-PWR: 1 sec.
  • These sensors are only for indoor use.
  • Avoid dust, dirt, and steam.
  • Make sure that the product does not come in contact with oil, grease, organic solvents such as thinner, etc., strong acid or alkaline.
  • This product cannot be used in an environment containing inflammable or explosive gases.
  • Never disassemble or modify this product.
  • This product adopts EEPROM. Settings cannot be done a million times or more because of the EEPROM’s lifetime.
  • The power input must meet the following requirements:
    1. Be certified for its region of use
    2. Have an output hold time of at least 20 ms
    3. Have a rated output voltage of 12 to 24 V DC ±10% ripple P-P 10% or less and a current capacity of 0.5 A or more
    4. If CE marking compliance is required, have SELV (Safety Extra Low Voltage)/PELV (Protective Extra Low Voltage) in accordance with the EMC Directive