ST4-C11|小型安全光電感測器 [Type4] ST4
※ 實際商品可能與照片不同。
適合不含有規定:EU RoHS指令 2011/65/EU的6物質、以及EU RoHS指令2015/863/EU的4物質
品名 | ST4-C11 |
---|---|
型號 | ST4-C11 |
產品 | Compact Type 4 Safety Beam Sensor |
詳細 | Controller |
商品名稱 | 小型安全光電感測器 [Type4] ST4 |
※為了商品改進,規格和外觀可能會在不事先通知的情況下變更,敬請諒解。
詳細規格
為了商品改進,規格和外觀可能會在不事先通知的情況下變更,敬請諒解。
項目 | 內容 |
---|---|
品名 | ST4-C11 |
型號 | ST4-C11 |
產品名 | Compact Type 4 Safety Beam Sensor |
顯示價格 | Please contact our office |
Applicable standards | IEC 61496-1/2 (JIS B 9704-1/2 / UL 61496-1/2) (Type 4), ISO 13849-1 (Category 4, PLe), JIS B 9705-1 (Category 4), IEC 61508-1 to 7 (SIL3), IEC 62061 (SIL3), JIS C 0508-1 to 7 (SIL3), UL 1998, OSHA 1910.212, OSHA 1910.217 (C), ANSI B11.1 to B11.19, ANSI/RIA R15.06, ANSI/ISA S84.01 (SIL3) (Note) Complies with those standards only when the controller is used in combination with the sensor head ST4-x. |
CE marking directive compliance | Machinery Directive, EMC Directive, RoHS Directive |
Power voltage | 24 V DC +10-15 % Ripple P-P 10 % or less |
Current consumption | 100 mA or less (excluding sensor head ST4-Ax) |
PFHD | Refer to the following table(Note: (Probability of dangerous failure per hour) depends on number of single beam sensor ST4-A□ connected to controller.) |
MTTFD | More than 100 years (Note:Mean time to dangerous failure (in years)) |
Environmental resistance:Degree of protection | Enclosure: IP40 (IEC) Terminal: IP20 (IEC) |
Environmental resistance:Ambient temperature | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 ℃ -13 to +158 ℉ |
Environmental resistance:Ambient humidity | 30 to 85 % RH, Storage: 30 to 95 % RH |
Environmental resistance:Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
Environmental resistance:Insulation resistance | 20 MOhm or more with 500 V DC mega between all supply terminals connected together and enclosure |
Environmental resistance:Vibration resistance | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude or maximum acceleration 90 m/s2 in X, Y and Z directions for two hours each< |
Environmental resistance:Shock resistance | 300 m/s2 acceleration in X, Y and Z directions three times each |
Material | Enclosure: ABS |
Applicable sensor head | ST4-Ax |
Applicable sensor head:No. of series connections | Interference prevention possible when up to a maximum of 6 sets are connected(When the maximum of 3 controllers are connected together, interference prevention is possible for up to 18 sets) |
Control outputs (OSSD 1, OSSD 2) | PNP open-collector transistor / NPN open-collector transistor Dual output x 1 system (Set using output polarity selection switch) [PNP output] Maximum source current: 200 mA Applied voltage: same as the supply voltage (between control output and +V) Residual voltage: 2.5 V or less (at 200 mA source current) Leakage current: 200 micro A or less (including power OFF condition) Maximum load capacity: 1 micro F (from no-load to max. source current) Load wiring resistance: 3 Ohm or less (between control output and load) [NPN output] Maximum sink current: 200 mA Applied voltage: same as the supply voltage (between control output and 0 V) Residual voltage: 2.0 V or less (at 200 mA sink current) Leakage current: 200 micro A or less (including power OFF condition) Maximum load capacity: 1 micro F (from no-load to max. sink current) Load wiring resistance: 3 Ohm or less (between control output and load) (Note) If the total current of the control outputs (OSSD1, OSSD2), auxiliary outputs, and muting lamp output exceeds 400 mA, the wiring resistance between the controller and the power supply should be 1 Ohm or less. In addition, if the total current is 400 mA or less, the wiring resistance between the controller and the power supply should be 2 Ohm or less. |
Control outputs (OSSD 1, OSSD 2):Operation mode | ON when all beams of the connected ST4-Axs are received OFF when one or more beams of the connected ST4-Axs are interrupted OFF during lockout |
Control outputs(OSSD1, OSSD2):Protection circuit | Incorporated |
Response time | OFF response: 25 ms or less ON response: 90 ms or less (auto reset) / 140 ms or less (manual reset) |
Auxiliary outputs | PNP open-collector transistor / NPN open-collector transistor (Set using output polarity selection switch) ST4-C11: one output ST4-C12EX: four outputs [PNP output] Maximum source current: 100 mA Applied voltage: same as the supply voltage (between auxiliary output and +V) Residual voltage: 2.5 V or less (at 100 mA source current) [NPN output] Maximum sink current: 100 mA Applied voltage: same as the supply voltage (between auxiliary output and 0 V) Residual voltage: 2.0 V or less (at 100 mA sink current) (Note) If the total current of the control outputs (OSSD1, OSSD2), auxiliary outputs, and muting lamp output exceeds 400 mA, the wiring resistance between the controller and the power supply should be 1 Ohm or less. In addition, if the total current is 400 mA or less, the wiring resistance between the controller and the power supply should be 2 Ohm or less. |
Auxiliary outputs:Operation mode | OFF when all beams of the connected ST4-Axs are received ON when one or more beams of the connected ST4-Axs are interrupted |
Auxiliary outputs:Protection circuit | Incorporated |
Muting lamp output | - (Note) If the total current of the control outputs (OSSD1, OSSD2), auxiliary outputs, and muting lamp output exceeds 400 mA, the wiring resistance between the controller and the power supply should be 1 Ohm or less. In addition, if the total current is 400 mA or less, the wiring resistance between the controller and the power supply should be 2 Ohm or less. |
Muting lamp output:Protection circuit | Incorporated |
Connection terminal | Detachable spring-cage terminal |
Wiring cable | Terminal block connector: 0.2 to 1.5 mm2 |
Weight | Net weight: 180 g approx Gross weight: 390 g approx |