SF-C12|安全光柵專用控制模組 SF-C10
停止接單
停產時期 (JST)
※ 實際商品可能與照片不同。
適合不含有規定:EU RoHS指令 2011/65/EU的6物質、以及EU RoHS指令2015/863/EU的4物質
詳細規格
項目 | 內容 |
---|---|
品名 | SF-C12 |
型號 | SF-C12 |
顯示價格 | Please contact our office |
產品名 | Exclusive Control Unit for Safety Light Curtain |
Connectable safety light curtains | SF4B / SF4B-G series |
Applicable standards | EN 61496-1 (Type 4), EN 55011, EN ISO 13849-1 (Category 4, PLe), IEC 61496-1 (Type 4), ISO 13849-1 (Category 4, PLe),JIS B 9704-1 (Type 4), JIS B 9705-1(Category 4), ANSI/UL 61496-1 (Type 4) |
Applicable regulations | CE Marking (Machinery Directive, EMC Directive, RoHS Directive) |
Power voltage | 24 V DC ±10 % Ripple P-P 10 % or less |
Current consumption | 100 mA or less (without light curtain) |
Fuse rating | Built-in electronic fuse, Triggering current: 0.5 A or more, Reset after power down |
Safety output | NO contact × 2 (13-14, 23-24) |
Safety output:Application category | AC-15, DC-13 (IEC 60947-5-1) |
Safety output:Rated operation voltage (Ue) /Rated operation current (le) | 1 A / 24 V DC, resistive load (For inductive load, during contact protection) Min. applicable load: 15 mA (at 24 V DC) |
Safety output:Contact material / contacts | AgNiO + 0.2 micro m 0.008 mil Au plating, self cleaning, positively driven |
Safety output:Contact resistance | 50 mOhm or less (initial value) |
Safety output:Contact protection fuse rated | 3 A (slow blow) |
Safety output:Mechanical lifetime | 10,000,000 times or more (open/close frequency of 180 times/min) (Note:The life expectancy of the relay varies depending on the type of load, open / close frequency, ambient conditions and others.) |
Safety output:Electrical lifetime | 100,000 times or more (open/close frequency of 20 times/min, 230 V AC, 3 A, using resistance load) (Note:The life expectancy of the relay varies depending on the type of load, open / close frequency, ambient conditions and others.) |
Pick-up delay(Auto reset / Manual reset) | 30 ms or less / 30 ms or less |
Response time | 14 ms or less |
Auxiliary outputs | Safety relay contact (NC contact) × 1 (31-32) (Related to enabling path) |
Auxiliary output:Rated operation voltage / current | 30 V DC / 3 A, Min. applicable load: 15 mA (at 24 V DC) |
Auxiliary output:Contact protection fuse rated | 3 A (slow blow) |
Semiconductor auxiliary output(AUX) | - |
Semiconductor auxiliary output(AUX):Output operation | - |
Excess voltage category | III |
Indicators:Power supply (Ui) | Green LED (lights up when the power is ON) |
Indicators:Safety output [OUT] | Green LED (lights up when safety output is closed) (Note:The operation indicator is marked as "Enabling" on the unit for SF-C12.) |
Indicators:Interlock (INTER_LOCK) | - |
Indicators:Fault (FAULT) | Orange LED (lights up when two safety light curtain input polarity selection switch settings are different) |
External relay monitor function | Incorporated (Note:Terminals for utilizing the functions of the SF4B / SF4B-G series are available.) |
Trailing edge function | Incorporated |
Polarity selection function | Incorporated (Sliding switch allows selection of plus/minus ground)Minus ground: Correspond to PNP output safety light curtainPlus ground: Correspond to NPN output safety light curtain (Note:Please switch the sliding switch to the PNP side for minus ground and to the NPN side for plus ground.) |
Pollution degree | 2 |
Environmental resistance:Degree of protection | IP65 |
Environmental resistance:Ambient temperature | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 ℃ -13 to +158℉ |
Environmental resistance:Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Environmental resistance:Vibration resistance | Resistance 10 to 55 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y, and Z directions for two hours each |
Enclosure material | Die-cast aluminium |
Connection terminal | European terminal |
Weight | Net weight: 1 kg approx. |