CX-423-P|小型光電感測器 [放大器內藏] CX-400 Ver.2
※ 實際商品可能與照片不同。
適合不含有規定:EU RoHS指令 2011/65/EU的6物質、以及EU RoHS指令2015/863/EU的4物質
品名 | CX-423-P |
---|---|
型號 | CX-423-P |
產品 | Compact Photoelectric Sensor |
詳細 | Diffuse reflective(Narrow-view) |
商品名稱 | 小型光電感測器 [放大器內藏] CX-400 Ver.2 |
※為了商品改進,規格和外觀可能會在不事先通知的情況下變更,敬請諒解。
詳細規格
為了商品改進,規格和外觀可能會在不事先通知的情況下變更,敬請諒解。
項目 | 內容 |
---|---|
品名 | CX-423-P |
型號 | CX-423-P |
產品名 | Compact Photoelectric Sensor |
顯示價格 | Please contact our office |
Applicable regulations and certifications | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), UL Recognition Certification |
Sensing range | 70 to 300 mm 2.756 to 11.811 in (Note) The sensing range and hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 × 200 mm 7.874 × 7.874 in) as the object. |
Sensing object | Opaque, translucent or transparent object(Min. sensing object: Ø0.5 mm Ø0.020 in copper wire) (Note) Make sure to confirm detection with an actual sensor before use. |
Hysteresis | 15 % or less of operation distance (Note) The sensing range and hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 × 200 mm 7.874 × 7.874 in) as the object. |
Repeatability(perpendicular to sensing axis) | 0.5 mm 0.020 in or less |
Supply voltage | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
Current consumption | 15 mA or less |
Output | PNP open-collector transistor - Maximum source current: 100 mA - Applied voltage: 30 V DC or less (between output and +V) - Residual voltage: 2 V or less (at 100 mA source current), 1 V or less (at 16 mA source current) |
Output:Output operation | Switchable either Light-ON or Dark-ON |
Output:Short-circuit protection | Incorporated |
Response time | 1 ms or less |
Operation indicator | Orange LED(lights up when the output is ON) (incorporated on the receiver for thru-beam type) |
Stability indicator | Green LED(lights up under stable light received condition or stable dark condition) (incorporated on the receiver for thru-beam type) |
Power indicator | - |
Sensitivity adjuster | Continuously variable adjuster(incorporated on the receiver for thru-beam type) |
Automatic interference prevention function | Incorporated(Two units of sensors can be mounted close together.) |
Protection | IP67 (IEC) |
Ambient temperature | - 25 to +55℃ -13 to +131℃ ℉ (No dew condensation or icing allowed ), Storage: -30 to +70℃ -22 to +158℃ ℉ |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Ambient illuminance | Incandescent light: 3,000 lx or less at the light-receiving face |
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
Insulation resistance | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
Vibration resistance | 10 to 500 Hz frequency, 1.5 mm 0.059 in amplitude (10 G max.) in X, Y and Z directions for two hours each |
Shock resistance | 500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each |
Emitting element (modulated) | Red LED |
Emitting element (modulated):Peak emission wavelength | 645 nm 0.025 mil |
Material | Enclosure: PBT (polybutylene terephthalate) Lens: acrylic Indicator cover: acrylic |
Cable | 0.2 mm23-core cabtyre cable, 2 m 6.562 ft long |
Cable extension | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. |
Weight | Net weight: 50 g approx. Gross weight: 60 g approx. |
Accessory | - |