Exclusive Control Unit for Safety Light Curtain SF-C10

  • Basic Information

  • Order guide

  • Specifications

  • Dimensions

  • Circuit/ Wiring

  • Cautions For Use

Partly Order Discontinued

Last time buy (JST)

March 31, 2023

------------------------------ Tab1 showing ------------------------------

Basic Information

Less setup time for safety circuits

UL/C-UL,CE,TUV,UKCA Approved

CE : Machinery Directive, EMC Directive
UKCA : Machinery Regulations, EMC Regulations
UL : Approved Listing

------------------------------ Tab2 showing ------------------------------

Order guide

DesignationAppearanceModel No.Applicable cable (Note)Description
Connector
connection type
control unit
SF-C11SF-C11Safety light curtain connection cable:
SFB-CB□
(For SF4B series)
SF2B-CB□
(For SF2B series)
Extension cable: SFB-CCJ10□
Use 8-core cable with connector to connect to the safety
light curtain.
Compatible with up to Control Category 4.
Interference prevention wires and muting function cannot
be used.
Slim type
control unit
SF-C13SF-C13Safety light curtain connection cable:
SFB-CCB□(-MU)
(For SF4B series)
SF2B-CCB□
(For SF2B series)
Extension cable: SFB-CC□(-MU)
Use a discrete wire cable to connect to the safety light
curtain. Muting function and interference prevention wires
can be used.
Compatible with up to Control Category 4.

Note: Refer to the SF4B series and SF2B series for details of applicable cable.

------------------------------ Tab3 showing ------------------------------

Specifications

Model No.SF-C11SF-C13
Connectable safety light curtainsSF4D / SF4B / SF4B-G / SF2B seriesSafety light curtains manufactured by our company
Applicable standardsEN 61496-1 (Type 4), EN 55011, EN ISO 13849-1:2015 (Category 4, , PLe), IEC 61496-1 (Type 4), ISO 13849-1:2015 (Category 4, PLe), JIS B 9704-1 (Type 4), JIS B 9705-1 (Category 4), ANSI/UL 61496-1 (Type 4), UL 1998 (Class 2) (Note 2)
Applicable regulationsCE Marking (Machinery Directive, EMC Directive, RoHS Directive),UKCA Marking (Machinery Regulations, EMC Regulations, RoHS Regulations)
Supply voltage24 V DC ±10 % Ripple P-P 10 % or less
Current consumption100 mA or less (without safety light curtain)
Fuse ratingBuilt-in electronic fuse, Triggering current: 0.5 A or more, Reset after power down
Enabling pathNO contact × 3 (13-14, 23-24, 33-34)
 UtilizationAC-15, DC-13 (IEC 60947-5-1)
Rated operation voltage (Ue) /
Rated operation current (le)
30 V DC / 6 A, 230 V AC / 6 A, resistive load
(For inductive load, during contact protection)
Min. applicable load: 10 mA (at 24 V DC) (Note 3)
30 V DC / 4 A, 230 V AC / 4 A, resistive load
(For inductive load, during contact protection)
Min. applicable load: 10 mA (at 24 V DC) (Note 3)
Contact material / contactsSilver tin oxide (AgSnO), self cleaning, positively driven
Contact resistance100 mΩ or less (initial value)
Contact protection fuse rating6 A (slow blow)4 A (slow blow)
Mechanical lifetime10,000,000 times or more (open/close frequency of 180 times/min) (Note 4)
Electrical lifetime100,000 times or more (open/close frequency of 20 times/min, 230 V AC, 3 A, using resistance load) (Note 4)
Pick-up delay (Auto reset/Manual reset)80 ms or less / 90 ms or less
Response time10 ms or less
Auxiliary outputSafety relay contact (NC contact) ×1 (41-42) (Related to enabling path)
 Rated operation voltage/current24 V DC / 2 A, Min. applicable load: 10 mA (at 24 V DC)
Contact protection fuse rating2 A (slow blow)
Semiconductor auxiliary output
(AUX)
<Minus ground (Setting for PNP)>
PNP open-collector transistor
• Maximum source current: 60 mA
• Applied voltage: same as supply voltage (between the auxiliary output and +V)
• Residual voltage: 2.3 V or less (at 60 mA source current)
• Leakage current: 2 mA or less <Plus ground (Setting for NPN)>
NPN open-collector transistor
• Maximum sink current: 60 mA
• Applied voltage: same as supply voltage (between the auxiliary output and 0V)
• Residual voltage: 1.5 V or less (at 60 mA sink current)
• Leakage current: 2 mA or less
PNP open‑collector transistor
• Maximum source current: 60 mA
• Applied voltage: same as supply voltage (between the auxiliary output and +V)
• Residual voltage: 2.3 V or less (at 60 mA source current)
• Leakage current: 2 mA or less
 Output operationRelated to auxiliary output of safety light curtainON when the safety light curtain is interrupted
Excess voltage categoryII
IndicatorsPower supply (Ui)Green LED (lights up when the power is ON)
Enabling path (OUT)Green LED (lights up when the enabling contacts are closed)
Interlock (INTER_LOCK)Yellow LED (lights up when the enabling contacts are opened)
Fault (FAULT)Yellow LED (blinks when fault occurs)
External relay monitor functionIncorporated
Trailing edge functionIncorporated
Polarity selection
function (Note 5)
Incorporated (Sliding switch allows selection of plus/minus ground)
Minus ground: Correspond to PNP output safety light curtain
Plus ground: Correspond to NPN output safety light curtain
Incorporated (Cable connection allows selection of plus/minus ground)
Minus ground: Correspond to PNP output safety light curtain
Plus ground: Correspond to NPN output safety light curtain
Pollution degree2
Degree of protectionEnclosure: IP40, Terminal: IP20
Ambient temperature–10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: –25 to +70 ℃ –13 to +158 ℉
Ambient humidity30 to 85 % RH, Storage: 30 to 95 % RH
Vibration resistanceMalfunction resistance 10 to 55Hz, 0.35 mm 0.014 in double amplitude 20 times each in X, Y, and Z directions
Connection terminalDetachable spring-cage terminalSpring-cage terminal
Enclosure materialABS
WeightNet weight: 320 g approx.Net weight: 200 g approx.

Notes:
1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 .
2) SF-C11 and SF-C13 comply with UL 1998 (Class 2).
3) If several SF-C11 or SF-C13 units are being used in a line together, leave a space of 5 mm 0.197 in or more between each unit. If the units are touching each other, reduce the rated operating current for safety output in accordance with the ambient operating temperature as shown in the graphs below.
4) The life expectancy of the relay varies depending on the type of load, open / close frequency, ambient conditions and others.
5) Please switch the sliding switch to the PNP side for minus ground and to the NPN side for plus ground.

Discontinued products

Model No.SF-C12
Connectable safety light curtainsSF4B / SF4B-G series
Applicable standardsEN 61496-1 (Type 4), EN 55011, EN ISO 13849-1 (Category 4, PLe), IEC 61496-1 (Type 4), ISO 13849-1 (Category 4, PLe),
JIS B 9704-1 (Type 4), JIS B 9705-1(Category 4), ANSI/UL 61496-1 (Type 4)
Applicable regulationsCE Marking (Machinery Directive, EMC Directive, RoHS Directive)
Control categoryISO 13849-1 (EN ISO 13849-1, JIS B 9705-1) compliance up to Category 4, PLe standards
Supply voltage /
Current consumption
24 V DC ±10 % Ripple P-P 10 % or less / 100 mA or less (without safety light curtain)
Fuse ratingBuilt-in electronic fuse, Triggering current: 0.5 A or more, Reset after power down
Safety outputNO contact × 2 (13-14, 23-24)
 UtilizationAC-15, DC-13 (IEC 60947-5-1)
Rated operation voltage (Ue) /
Rated operation current (le)
24 V DC / 1 A, resistive load
(For inductive load, during contact protection)
Min. applicable load: 15 mA (at 24 V DC)
Contact material / contactsAgNiO + 0.2 μm 0.008 mil Au plating, self cleaning, positively driven
Contact resistance50 mΩ or less (initial value)
Contact protection fuse rating3 A (slow blow)
Mechanical lifetime10,000,000 times or more (open/close frequency of 180 times/min) (Note 2)
Electrical lifetime100,000 times or more (open/close frequency of 20 times/min, 230 V AC, 3 A, using resistance load) (Note 2)
Pick-up delay (Auto reset/Manual reset)30 ms or less / 30 ms or less
Response time14 ms or less
Auxiliary outputSafety relay contact (NC contact) × 1 (31-32) (Related to enabling path)
 Rated operation voltage/current30 V DC / 3 A, Min. applicable load: 15 mA (at 24 V DC)
Contact protection fuse rating3 A (slow blow)
Semiconductor auxiliary output
(AUX)
-
 Output operation-
Excess voltage categoryIII
IndicatorsPower supply (Ui)Green LED (lights up when the power is ON)
Safety output [OUT (Note 3)]Green LED (lights up when safety output is closed)
Interlock (INTER_LOCK)-
Fault (FAULT)Orange LED (lights up when two safety light curtain
input polarity selection switch settings are different)
External relay monitor functionIncorporated (Note 4)
Trailing edge functionIncorporated
Polarity selection
function (Note 5)
Incorporated (Sliding switch allows selection of plus/minus ground)
Minus ground: Correspond to PNP output safety light curtain
Plus ground: Correspond to NPN output safety light curtain
Pollution degree2
ProtectionIP65
Ambient temperature–10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: –25 to +70 ℃ –13 to +158 ℉
Ambient humidity35 to 85 % RH, Storage: 35 to 85 % RH
Vibration resistanceResistance 10 to 55 Hz frequency, 0.75 mm 0.030 in
amplitude in X, Y, and Z directions for two hours each
Connection terminalEuropean terminal
Enclosure materialDie-cast aluminum
WeightNet weight: 1 kg approx.

Notes:
1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 .
2) The life expectancy of the relay varies depending on the type of load, open / close frequency, ambient conditions and others.
3) The operation indicator is marked as "Enabling" on the unit for SF-C12.
4) Terminals for utilizing the functions of the SF4B / SF4B-G series are available.
5) Please switch the sliding switch to the PNP side for minus ground and to the NPN side for plus ground.

Model No.SF-C14EX(-01) (Note 2)
Connectable safety light curtainsSF4B / SF4B-G series
Applicable standardsIEC 61496-1 (Type 4), EN 55011, EN ISO 13849-1 (Category 4, PLe), IEC 61496 (Type 4), ISO 13849-1 (Category 4, PLe),
JIS B 9704-1 (Type 4), JIS B 9705-1 (Category 4, PLe), ANSI/UL 61496-1 (Type 4), UL 1998 (Class 2)
CE marking directive complianceMachinery Directive, EMC Directive, RoHS Directive
Control categoryISO 13849-1 (EN ISO 13849-1, JIS B 9705-1) compliance up to Category 4, PLe standards
Supply voltage24 V DC ±10 % Ripple P-P 10 % or less
Current consumption0.2 A or less (Excluding safety light curtain and other external connecting device)
Safety outputs
(Safety output 1
Safety output 2
Safety output 3)
PNP open-collector transistor 2 outputs × 3 or NPN open-collector transistor 2 outputs × 3 (selectable using a slider switch)
<When PNP output is selected>
• Maximum source current: 200 mA
• Applied voltage: same as supply voltage
(between the safety output and +V)
• Residual voltage: 2 V or less (at 200 mA source current)

<When NPN output is selected>
• Maximum sink current: 200 mA
• Applied voltage: same as supply voltage
(between the safety output and 0 V)
• Residual voltage: 2 V or less (at 200 mA sink current)
 Operation mode
(Output operation)
Safety output 1: ON when the safety light curtain is in light receiving condition, OFF when the safety light curtain is in light interrupted condition (Note 3)
Safety output 2: ON when the safety light curtain is in light receiving condition or the muting function is valid
OFF when the safety light curtain is in light interrupted condition and the muting function is invalid (Note 3)
Safety output 3: ON when the emergency stop is invalid, OFF when the emergency stop is valid
Protection circuit
(Short-circuit protection)
Incorporated
Response timeOFF response: 14 ms or less (Safety output 1 and 2: including the response time of the safety light curtain)
ON response: 90 ms or less (auto-reset) / 140 ms or less (manual reset) (Note 4)
Auxiliary outputs
[Auxiliary output 1
Auxiliary output 2
Auxiliary output 3
Auxiliary output 4 (Note 5)]
PNP open-collector transistor × 3 or NPN open-collector transistor × 3 (selectable using a slider switch)
<When PNP output is selected>
• Maximum source current: 60 mA
• Applied voltage: same as supply voltage
(between the auxiliary output and +V)
• Residual voltage: 2 V or less (at 60 mA source current)

<When NPN output is selected>
• Maximum sink current: 60 mA
• Applied voltage: same as supply voltage
(between the auxiliary output and 0 V)
• Residual voltage: 2 V or less (at 60 mA sink current)
 Operation mode
(Output operation)
Auxiliary output 1: ON when the muting function is invalid, OFF when the muting function is valid
Auxiliary output 2: ON when the override function is invalid, OFF when the override function is valid
Auxiliary output 3: ON when the muting lamp is normal, OFF when the muting lamp is error
Auxiliary output 4: ON when the safety light curtain is in light interrupted condition, OFF when the safety light curtain is in light
receiving condition (Note 5)
Protection circuit
(Short-circuit protection)
Incorporated
Muting lamp outputApplicable muting lamp: 24 V DC, 3.6 to 30 W (L1, L2 of each unit)
 Protection circuit
(Short-circuit protection)
Incorporated
PFHD (Note 6)1.66 × 10-10
MTTFD (Note 6)100 years or more
ProtectionEnclosure: IP40, Terminal: IP20
Ambient temperature–10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: –25 to +70 ℃ –13 to +158 ℉
Ambient humidity30 to 85 % RH, Storage: 30 to 95 % RH
Dielectric strength voltage1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
Vibration resistance10 to 55 Hz frequency, 0.35 mm 0.014 in double amplitude in X, Y and Z directions for two hours each
Shock resistance30 G acceleration in X, Y and Z directions three times each
MaterialEnclosure: ABS
Connection terminalDetachable spring-cage terminal
WeightNet weight: 250 g approx.

Notes:
1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
2) The handy-controller SFB-HC (optional) cannot be used with SF-C14EX-01.
3) Both safety output 1 and 2 are OFF when the emergency stop is valid regardless of whether the safety light curtain is in the light receiving or light interrupted condition.
4) The auto-reset cannot be used with safety output 3.
5) The auxiliary output incorporated in the SF4B / SF4B-G series is output.
6) PFHD: Probability of dangerous failure per hour, MTTFD: Mean time to dangerous failure (in years)

------------------------------ Tab4 showing ------------------------------

Dimensions

  • Unit: mm in

SF-C11

Control unit (Optional)

SF-C11

SF-C13

Control unit (Optional)

SF-C13

Discontinued products

SF-C12
Control unit (Optional)

SF-C12

SF-C14EX(-01)
Application expansion unit

SF-C14EX(-01)

------------------------------ Tab5 showing ------------------------------

I/O Circuit and Wiring diagrams

Wiring diagram of SF-C11 and SF4B / SF4B-G series or SF2B series (Control Category 4 or 2)

For PNP output (minus ground)

  • Set the safety light curtain input polarity selection switch to the PNP side and ground the 0 V line.

Wiring diagram of SF-C11 and SF4B / SF4B-G series or SF2B series (Control Category 4 or 2)

Notes:
1) The above diagram is when using manual reset. If automatic reset is used, disconnect the lead from X2 and connect it to X3. In this case, a reset (RESET) button is not needed.
2) Use a momentary-type switch as the reset (RESET) button.
3) Emission halt occurs when the test (TEST) button is open, and emission occurs when the test (TEST) button is short-circuited. If not using the test (TEST) button, short-circuit T1 and T2. However, in case of SF2B series, use a test rod or similar to interrupt the light in order to carry out self-diagnosis separately.

For NPN output (plus ground)

  • In the above diagram, set the safety light curtain input polarity selection switch to the NPN side and ground the + side.

For NPN output (plus ground)

When connecting the SF-C11 to the safety light curtains, make sure to use the 8-core connection cable with a connector. Refer to the SF4B / SF4B-G series and SF2B series pages for details. SFB-CB□, SF2B-CB□, SFB-CCJ10□


Terminal arrangement diagram

SF-C11 Terminal arrangement diagram

TerminalFunction
A1+24 V DC
A20 V
13-14, 23-24, 33-34Safety output (NO contact × 3)
41-42Auxiliary output (NC contact × 1)
X1Reset output terminal
X2Reset input terminal (Manual)
X3Reset input terminal (Automatic)
ANot used
B
T1Test output terminal
T2Test input terminal
AUXSemiconductor auxiliary output

Pin layout for safety light curtain connectors

SF-C11 Pin layout for light curtain connectors

Connector pin No.Emitter side connectorReceiver side connector
Interlock(Note)OSSD 2
+24 V DC+24 V DC
Emission haltOSSD 1
Auxiliary outputEDM (External relay monitor)
Synchronization wire +Synchronization wire +
Synchronization wire –Synchronization wire –
0 V0 V
Shielded wireShielded wire

Note: It is not used with the SF2B series.

Wiring diagram of SF-C13 and SF4B / SF4B-G series or SF2B series (Control Category 4 or 2)

For PNP output (minus ground)

  • Connect the safety light curtain control outputs OSSD1 and OSSD2 to S1 and S2 respectively.

Notes:
1) The above diagram is when using manual reset. If automatic reset is used, disconnect the lead from X2 and connect it to X3. In this case, a reset (RESET) button is not needed.
2) Use a momentary-type switch as the reset (RESET) button.
3) This is a test input (pink) for the SF2B series.
4) This is not equipped on the SF2B series.
5) This is a shield for the SF2B series. Output polarity cannot be set.

For NPN output (plus ground)

  • Connect the safety light curtain control outputs OSSD1 and OSSD2 to S4 and S2 respectively and ground the + side.

Notes:
1) The above diagram is when using manual reset. If automatic reset is used, disconnect the lead from X2 and connect it to X3. In this case, a reset (RESET) button is not needed.
2) Use a momentary-type switch as the reset (RESET) button.
3) This is a test input (pink) for the SF2B series.
4) This is not equipped on the SF2B series.
5) This is a shield for the SF2B series. Output polarity cannot be set.

When connecting the SF-C13 to the safety light curtains, make sure to use a discrete wire connection cable. Refer to the SF4B / SF4B-G series and SF2B series pages for details.
SFB-CCB□(-MU), SF2B-CCB□, SFB-CC□(-MU)

Terminal arrangement diagram

SF-C13 Terminal arrangement diagram

TerminalFunction
A1+24 V DC
A20 V
S1 to S4Safety light curtain control output (OSSD) input terminal
AUXSemiconductor auxiliary output
X1Reset output terminal
X2Reset input terminal (Manual)
X3Reset input terminal (Automatic)
13-14, 23-24, 33-34Safety output (NO contact × 3)
41-42Auxiliary output (NC contact × 1)

Use a separate terminal block to carry out wiring for safety light curtains that cannot be connected to the SF-C13.

Discontinued products

For PNP output (minus ground)

  • Set the two safety light curtain input polarity selection switches to the PNP side and connect the F.G. terminal to the 0 V line.

Note: The above diagram is when using manual reset. If automatic reset is used, connect a normal close-type pushbutton switch between T1 and T2 and leave between X1 and X2 open.

For NPN output (plus ground)

  • In the above diagram, set the two safety light curtain input polarity selection switches to the NPN side and connect the F.G. terminal to the + side.

When connecting the SF-C12 to the safety light curtains, make sure to use the 12-core connection cable with a connector.
Refer to the SF4B / SF4B-G series pages for details.
SFB-CB05-MU (Cable length: 0.5 m 1.640 ft)
SFB-CCJ10E-MU (Extension cable for emitter, cable length: 10 m 32.808 ft)
SFB-CCJ10D-MU (Extension cable for receiver, cable length: 10 m 32.808 ft)


Terminal arrangement diagram

TerminalFunction
FGFrame ground (F.G.) terminal
A20 V
A1+24 V DC
13-14, 23-24Safety output (NO contact × 2)
31-32Auxiliary output (NC contact × 1)
FB4External relay monitor terminal 2
FB3
FB2External relay monitor terminal 1
FB1
TerminalFunction
R+Interference prevention wire – (Receiver side)
R–Interference prevention wire + (Receiver side)
E+Interference prevention wire – (Emitter side)
E–Interference prevention wire + (Emitter side)
T2Emission halt input terminal
T1
X2Automatic reset / manual reset selection terminal
Manual reset: X1 – X2 short-circuited
X1

Pin layout for safety light curtain connectors

SF-C12 Pin layout for light curtain connectors

Note:Input and output for pin Nos.
⑪ and ⑫ are not used by this product.

Connector pin No.Emitter side connectorReceiver side connector
InterlockOSSD 2
+24 V DC+24 V DC
Emission haltOSSD 1
Auxiliary outputEDM (External relay monitor)
Synchronization wire +Synchronization wire +
Synchronization wire –Synchronization wire –
0 V0 V
Shielded wireShielded wire
Interference prevention wire +Interference prevention wire +
Interference prevention wire –Interference prevention wire –
(Override input)(Muting input 1)
(Muting lamp output)(Muting input 2)

For PNP output (minus ground)

  • Set the output polarity selection switch to the PNP side and ground the 0 V line.

Notes:
1) The above diagram is when using manual reset. If automatic reset is used, disconnect the lead from X12 and X22, and connect them to X13 and X23 as shown by the dotted lines. In this case, a reset (RESET) button is not needed. Terminals X31 to X32 are for manual reset only.
2) Use a momentary-type switch for the reset (RESET) button.

For NPN output (plus ground)

  • Set the output polarity selection switch to the NPN side and ground the + side of the power supply input.

Notes:
1) The left diagram is when using manual reset. If automatic reset is used, disconnect the lead from X12 and X22, and connect them to X13 and X23 as shown by the dotted lines. In this case, a reset (RESET) button is not needed. Terminals X31 to X32 are for manual reset only.
2) Use a momentary-type switch for the reset (RESET) button.

・When connecting the SF-C14EX to the safety light curtains, make sure to use the following connecting cable.
SFB-CB05-EX (Cable length: 0.5 m 1.640 ft)
SFB-CB5-EX (Cable length: 5 m 16.404 ft)
SFB-CB10-EX (Cable length: 10 m 32.808 ft)

・If the NO (Normally Open) contact switch is used as a muting sensor,wire it as shown in the figure below.

・If the emergency stop switch is not used, short-circuit between the terminals S11 to S12 and S21 to S22 directly.

Terminal arrangement diagram

SF-C14EX(-01) Terminal arrangement diagram

TerminalFunctionTerminalFunction
14Safety output 1, Light received
/ Light interrupted output of the safety light curtain
S11Emergency stop contact input
2 NC input
Between S11 and S12
Between S21 and S22
24S12
34Safety output 2, Safety light curtain output including the muting functionS21
44S22
54Safety output 3 Emergency stop outputX11Safety output 1 reset input
X11 - X12: Manual reset
X11 - X13: Auto-reset
64X12
S3+Muting sensor input 1 (PNP output type)
S3+, S3–: Power supply
S3: Sensor output
X13
S3X21Safety output 2 reset input
X21 - X22: Manual reset
X21 - X23: Auto-reset
S3–X22
S4+Muting sensor input 2(NPN output type)
S4+, S4–: Power supply
S4: Sensor output
X23
S4X31Safety output 3 reset input
X31 - X32: Manual reset
S4–X32
T1Test input terminal
Open: Test mode
Short-circuit: Normal operation
AUX1Auxiliary output 1, Muting output
T2AUX2Auxiliary output 2, Override output
O1Override input terminal
Open: Invalid
Short-circuit: Valid
AUX3Auxiliary output 3, Blown lamp output
O2AUX4Auxiliary output 4, Safety light curtain auxiliary output
L1+Muting lamp output 1IE+Interference prevention terminal, Emitter side +
L1–IE–Interference prevention terminal, Emitter side –
L2+Muting lamp output 2IR+Interference prevention terminal, Receiver side +
L2–IR–Interference prevention terminal, Receiver side –
A1+24 V DC-
A20 V-

Pin layout for light curtain connectors

SF-C14EX(-01) Terminal arrangement diagram Pin layout for light curtain connectors

Connector pin No.Emitter side connectorReceiver side connector
Interference prevention wire +Interference prevention wire +
+24 V DC+24 V DC
Interference prevention wire –Interference prevention wire –
Auxiliary outputNot used
Synchronization wire +Synchronization wire +
Synchronization wire –Synchronization wire –
0 V0 V
Shielded wireShielded wire

------------------------------ Tab6 showing ------------------------------

Cautions For Use

Part description and function [SF-C14EX(-01)]

No.DescriptionFunction
Emitter side connectorThe emitter of SF4B / SF4B-G series is connected.
Receiver side connectorThe receiver of SF4B / SF4B-G series is connected.
Digital indicator (Red)Lights up or blinks when there is a problem.
Lights up when blanking function is enabled.
Power indicator (Ui) (Green)Lights up when the power is ON.
Test input indicator (TEST) (Yellow)Lights up when test input is enabled. Blinks while communication with SFB-HC (optional) handy-controller is in progress. (Excluding SF-C14EX-01)
Muting sensor 1 indicator (MU1) (Orange)Lights up when muting sensor 1 is ON.
Muting sensor 2 indicator (MU2) (Orange)Lights up when muting sensor 2 is ON.
Safety output 1 indicator (OUT1) (Green)Lights up when safety output 1 is ON.
Safety output 2 indicator (OUT2) (Green)Lights up when safety output 2 is ON.
Safety output 3 indicator (OUT3) (Green)Lights up when safety output 3 is ON.
Output polarity selection switchPNP (minus ground) or NPN (plus ground) can be selected. The factory setting is PNP (minus ground).
Auxiliary output 1 indicator (AUX1) (Orange)Lights up when auxiliary output 1 is ON.
Auxiliary output 2 indicator (AUX2) (Orange)Lights up when auxiliary output 2 is ON.
Auxiliary output 3 indicator (AUX3) (Orange)Lights up when auxiliary output 3 is ON.
Interlock 1 indicator (INTER LOCK1) (Yellow)Lights up when interlock 1 is ON.
Interlock 2 indicator (INTER LOCK2) (Yellow)Lights up when interlock 2 is ON.
Interlock 3 indicator (INTER LOCK3) (Yellow)Lights up when interlock 3 is ON.

Wiring

  • The following solid wire and twisted wires (lead wire) are recommended.

SF-C11
Power supply and output line connector : 0.2 to 2.5mm2 (AWG24 to 12)
Signal line connector : 0.2 to 1.5mm2 (AWG24 to 16)

SF-C13
Single wire : ø0.4 to ø1.2mm ø0.016 to ø0.047 in (AWG26 to 16)
Twisted wire (lead wire) : 0.3 to 1.25mm2(AWG22 to 16)

SF-C14EX(-01)
Power supply line connector (A1, A2) : 0.2 to 2.5mm2(AWG24 to 12)
Other connectors ; 0.2 to 1.5mm2 (AWG24 to 16)

Output waveform (Safety output ON) [SF-C14EX(-01)]

  • When safety output is ON, self-diagnosis of the output circuit is carried out, so that the output transistor will periodically turn OFF. (OFF pulse width: 100 μs or less) When the OFF signal is fed back, the receiver judges the output circuit as normal. When the OFF signal is not fed back, the receiver judges either the output circuit or wiring as error, and the safety output maintains OFF status.
  • Since the OFF signal of SF-C14EX(-01) might cause malfunction, perform the connecting paying attention to the input response time of the machine to be connected to SF-C14EX(-01).

Time chart [SF-C14EX(-01)]

Normal operation

  • The diagram shows operation with safety outputs 1 and 2 in manual-reset mode.

  • The diagram above is the timing chart of SF-C14EX(-01) in normal operation.
  • In normal operation, auxiliary output 2 (override output) is maintained in the ON state.
  • In normal operation, auxiliary output 3 (muting lamp output) is maintained in the ON state.

Time chart [SF-C14EX(-01)]

Test input, Override input

  • The diagram shows operation with safety outputs 1 and 2 in auto-reset mode.

  • Safety outputs 1 and 2 are OFF during test input.
  • The override function becomes valid when all the conditions listed below are satisfied:
    • An incandescent lamp with 3.6 to 30 W is at least connected to either muting lamp output 1 or 2.
    • The signal is input to either muting sensor 1 or 2.
    • The override input terminal O1 and O2 is short-circuited and the test input terminal T1 / T2 is opened within 1 sec. (3 sec. continuously)
    If one of the three conditions above becomes invalid or the timing exceeds 60 sec., the override function becomes invalid.

Blown lamp output

  • The diagram shows operation with safety outputs 1 and 2 in auto-reset mode.

  • The lamps are monitored during muting state, and if either of them breaks, auxiliary output 3 is turned OFF. If only one lamp breaks, the muting state is maintained, however, if both lamps break, the muting state is canceled immediately.

Others

  • This device has been developed / produced for industrial use only.
  • When connecting this product to a product other than the connectable input device, the system does not conform to the control category 4 based on ISO 13849-1
    (EN ISO 13849-1, JIS B 9705-1).
  • The power supply unit of SF-C10 series uses the electronic fuse which does not require any replacement.
  • When the electronic fuse trips, turn off the power supply and eliminate the cause for the overcurrent. After that, turn the power back on.
  • The electronic fuse is not meant to be used for equipment that is operated continuously. Note that the specification may not be satisfied by continuous operation.
  • Make sure to carry out the wiring in the power supply off condition.
  • Wrong wiring will damage the product.
  • Verify that the supply voltage variation is within the rating. Note that if a voltage exceeding the rated range is applied, or if an AC power supply is directly connected, the unit may get burnt or damaged.
  • The DC power supply unit must satisfy the conditions given below:
    1) Power supply unit authorized in the region where this device is to be used.
    2) Power supply unit conforming to EMC Directive and Low-voltage Directive (In case CE conformity is required.)
    3) Power supply unit conforming to EMC Regulations and Low-voltage Regulations (In case UKCA conformity is required.)
    4) Power supply unit conforming to the Low-voltage Directive and with an output of 100 VA or less.
    5) The frame ground (F.G.) terminal must be connected to ground when using a commercially available switching regulator.
    6) Power supply unit with an output holding time of 20 ms or more.
    7) Use an isolation transformer for the DC power supply unit.
    8) If surges are likely to occur, take countermeasures such as connecting a surge absorber to the origin of the surge.
    9) Power supply unit corresponding to CLASS 2 (In case UL/c-UL conformity is required.)
    <Additional information>
    As provided in IEC 60536 (CLASS: Protection against Electric Shook), this power supply should require no ground earth and satisfy the insulation distance by double insulation or reinforced insulation.
    (If the power supply conforms to Low-voltage Directive and has an output of 100 VA or less, it can be used as a suitable product.)
  • Do not run the wires together with high-voltage lines or power lines or put them in the same raceway. This can cause malfunction due to induction.
  • This product is not dust-proof / splash proof. Be sure to put this product into a control box having IP54 construction. (Excluding SF-C12)
  • Avoid dust, dirt and steam.
  • Take care that the product does not come in direct contact with oil, grease, or organic solvents, such as, thinner, etc.
  • Note that this equipment is applicable only in the control circuit grounded in accordance with IEC 60204-1 and JIS B 9960-1, or in the control circuit in which the insulation monitor unit (ground fault detection unit) is included.
  • This unit is suitable for indoor use only.
  • The seal as shown in the drawing on the below is stuck to the engagement point of unit. If the seal is peeled off or broken, SF-C10 series will not be certified as “Safety equipment” and will not be covered by our guarantee.