The following applicable products and options are available continuously.
Designation | Model No. | Description | |||
---|---|---|---|---|---|
4-pin type snap male connector | SL-CP1 (White) [10 pcs. per set] | For 0.08 to 0.2 mm2 (Conductor cross-section area) Wire dia.: ø0.7 to ø1.2 mm ø0.028 to ø0.047 in | This snap male connector is used for connecting S-LINK I/O devices to SL-T8J(-PN) and SL-TP8J(-PN) 8-channel snap-connector I/O units as well as to SL-JK and SL-JK1 hook-up connectors. Applicable hook-up pliers: SL-JPC (for the SL-CP1 and SL-CP2) SL-JPE (for the SL-CP3) | ||
SL-CP2 (Black) [10 pcs. per set] | For 0.3 mm2 (Conductor cross-section area) Wire dia.: ø1.1 to ø1.6 mm ø0.043 to ø 0.063 in | ||||
SL-CP3 (Greenish blue) [10 pcs. per set] | For 0.5 mm2 (Conductor cross-section area) Wire dia.: ø1.7 to ø2.5 mm ø0.067 to ø0.098 in | ||||
SL-CP3 exclusive pliers | SL-JPE | 4-pin type snap male connector (SL-CP3) can be connected in one grip. | |||
Male / female connector exclusive pliers | SL-JPC | Snap female connector (SL-CJ1/CJ2, SL-CJ11/CJ12) and snap male connector (SL-CP1/CP2, SL-CP11/CP12) can be connected in one grip. | |||
Sensor mounting bracket for SL-A□ | MS-NX5-1 | Foot angled mounting bracket (The thru-beam type sensor needs two brackets.) | |||
MS-NX5-2 | Foot biangled mounting bracket (sensor protection bracket) (The thru-beam type sensor needs two brackets.) | ||||
MS-NX5-3 | Back angled mounting bracket (The thru-beam type sensor needs two brackets.) | ||||
Sensor mounting bracket for SL-N15 | MS-NA1-1 | Four bracket set [Four M4 (length 15 mm 0.591 in) screws with washers, eight nuts, four hooks, four spacers and eight M4 (length 18 mm 0.709 in) screws with washers are attached. (Spacers are not attached with MS-NA1-1.)] | |||
MS-NA2-1 | |||||
Sensor protection bracket for SL-N15 | MS-NA3 | It protects the sensor body. Two bracket set (Silver) [Four M4 (length 15 mm 0.591 in) screws with washers, and four nuts are attached.] | |||
MS-NA3-BK | It protects the sensor body. Two bracket set (Black) [Four M4 (length 15 mm 0.591 in) screws with washers, and four nuts are attached.] | ||||
Reflector mounting bracket | MS-RF23 | Reflector mounting bracket for RF-230 | |||
Slit mask for SL-N15 | OS-NA1-5 | The seal type slit mask restrains the amount of beam emitted or received. (Take care that the sensing range will be reduced when the slit mask is used.) | |||
Connector I/O unit mounting bracket, 8-branch connector tap mounting bracket | MS-DIN-3 | It is a DIN rail mounting bracket which can be fitted on the mounting base of SL-T8J, SL-TP8J, SL-T16C1, SL-TP16C1 and SL-T8PW. |
------------------------------ Tab2 showing ------------------------------
Cautions For Use
- Never use this product in a device for personal protection.
- In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country.
- Handle safety related or emergency stop signals without passing them through the S-LINK system due to fail-safe considerations.
- Before touching this product, remove any electrostatic charge that may be present on your body. There is a danger of this product getting damaged due to the electrostatic charge.
- The sensor & wire-saving link system S-LINK are not mutually interchangeable with the flexible wire-saving system S-LINK V and cannot be mixed or matched. Please exercise caution.
[Nevertheless, any of the exclusive 4-core flat cable, connectors, hook-up pliers, or SL-T8PW 8-branch connector taps can be used.]