PX-24|障礙物檢測感測器 PX-2
※ 實際商品可能與照片不同。
適合不含有規定:EU RoHS指令 2011/65/EU的6物質、以及EU RoHS指令2015/863/EU的4物質
品名 | PX-24 |
---|---|
型號 | PX-24 |
產品 | Long Range & Wide Area Photoelectric Sensor |
詳細 | Main sensors(Auxiliary sensor connectable model) |
商品名稱 | 障礙物檢測感測器 PX-2 |
※為了商品改進,規格和外觀可能會在不事先通知的情況下變更,敬請諒解。
詳細規格
為了商品改進,規格和外觀可能會在不事先通知的情況下變更,敬請諒解。
項目 | 內容 |
---|---|
品名 | PX-24 |
型號 | PX-24 |
產品名 | Long Range & Wide Area Photoelectric Sensor |
Regulatory compliance | EMC Directive, RoHS Directive |
Sensing range (OUT 1 and OUT 2 areas) | 3 m 9.843 ft (Note:The sensing range is specified for white non-glossy paper (300 x 300 mm 11.811 × 11.811 in) as the object.) |
Hysteresis | 15 % or less of operation distance (Note:The sensing range is specified for white non-glossy paper (300 x 300 mm 11.811 × 11.811 in) as the object.) |
Supply voltage | 10 to 31 V DC including ripple |
Power consumption | Under operation: 1.5 W or less, Under sleep condition: 0.3 W or less (without auxiliary sensor) (Note:Obtain the current consumption by the following calculation. Current consumption = Power consumption ÷ Supply voltage (e.g.) When the supply voltage is 12 V, the current consumption (operating condition) is: 1.5 W ÷ 12 V = 0.125 A = 125 mA) |
OUT1, OUT2 | NPN open-collector transistor ・Maximum sink current: 100 mA ・Applied voltage: 40 V DC or less between OUT 1 / OUT 2 and 0 V) ・Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current) * OUT1(OR circuit among the effective center, left, right, adjacent left / right OUT 1 areas and the effective auxiliary left / right areas) OUT2(OR circuit among the effective center, left and right OUT 2 areas) |
OUT1, OUT2:Output operation | Selectable either Light-ON or Dark-ON with a switch (Output operation of OUT 1 and OUT 2 is the same.) |
OUT1, OUT2:Short-circuit protection | Incorporated |
Extraneous light monitor output | NPN open-collector transistor ・Maximum sink current: 100 mA ・Applied voltage: 40 V DC or less (between extraneous light monitor output and 0 V) ・Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current) |
Extraneous light monitor output:Output operation | ON when modulated beam other than its own (including auxiliary sensor's) light is received |
Response time | 80 ms or less |
Operation indicators:OUT 1 area | Red LED (lights up when the beam is received in the effective OUT 1 areas) |
Operation indicators:OUT 2 area | Yellow LED (lights up when the beam is received in the effective OUT 2 areas) |
Sensitivity adjuster | Continuously variable adjusters (OUT 1, adjacent right OUT 1, adjacent left OUT 1 and OUT 2 areas are adjusted independently.) |
External sensitivity adjustment function | Sensitivity adjustment is possible with an analog input. |
Sensing area | Four sensing areas are selectable with dip switches. |
Sleep function | Operating / sleep selectable with external input |
Automatic Interference prevention function | Optical interference from up to 25 units is prevented. |
Protection | IP65 (IEC) |
Ambient temperature | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉ |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Ambient illuminance | Incandescent light: 3,000 lx or less at the light-receiving face |
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
Insulation resistance | 20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure |
Vibration resistance | 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (20 G max.) in X, Y and Z directions for two hours each |
Shock resistance | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each |
Emitting element | Infrared LED (Peak emission wavelength: 950 nm 0.037 mil, modulated) |
Material | Enclosure: ABS, Lens: Acrylic, Cover: Polycarbonate |
Cable | For input and output: 0.18 mm2 9-core (PX-24ES and PX-23ES: 12-core) cabtyre cable, 0.5 m 1.640 ft long For auxiliary sensor connection: 0.18 mm2 10-core connector attached cabtyre cable, 0.5 m 1.640 ft long10-core connector attached cabtyre cable, 0.5 m 1.640 ft long |
Cable extension | Extension up to total 100 m 328.084 ft (10 m 32.808 ft for auxiliary sensor connection) is possible with 0.3 mm2, or more, cable. |
Weight | Net weight: 210 g approx. Gross weight: 390 g approx. |
Accessory | MS-PX-2 (Main sensor mounting bracket): 1 set, Adjusting screwdriver: 1 pc. |