LS-H92-Y|數位雷射感測器 LS-400
※ 實際商品可能與照片不同。
適合不含有規定:EU RoHS指令 2011/65/EU的6物質、以及EU RoHS指令2015/863/EU的4物質
品名 | LS-H92-Y |
---|---|
型號 | LS-H92-Y |
產品 | Digital Laser Sensor |
詳細 | Sensor head (Coaxial retroreflective type) |
商品名稱 | 數位雷射感測器 LS-400 |
※為了商品改進,規格和外觀可能會在不事先通知的情況下變更,敬請諒解。
詳細規格
為了商品改進,規格和外觀可能會在不事先通知的情況下變更,敬請諒解。
項目 | 內容 |
---|---|
品名 | LS-H92-Y |
型號 | LS-H92-Y |
產品名 | Digital Laser Sensor |
顯示價格 | Please contact our office |
Regulatory compliance | EMC Directive, RoHS Directive |
Applicable amplifiers | LS-401(P), LS-401(P)-C2, LS-403 |
Sensing range:U-LG mode | 0.2 to 30 m 0.656 to 98.425 ft (Note) The sensing range is the value for the RF-230 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.2 m 0.656 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity. |
Sensing range:STD mode | 0.2 to 20 m 0.656 to 65.617 ft (Note) The sensing range is the value for the RF-230 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.2 m 0.656 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity. |
Sensing range:FAST mode | 0.2 to 10 m 0.656 to 32.808 ft (Note) The sensing range is the value for the RF-230 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.2 m 0.656 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity. |
Sensing range:H-SP mode | 0.2 to 10 m 0.656 to 32.808 ft (Note) The sensing range is the value for the RF-230 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.2 m 0.656 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity. |
Operation indicator | Orange LED (lights up when the amplifier output is ON) |
Laser emission indicator | Green LED (lights up during laser emission) |
Spot-shape adjuster | - |
Protection | IP40 (IEC) |
Ambient temperature | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℉ |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Ambient illuminance | Incandescent light: 3,000 lx or less at the light-receiving face |
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
Insulation resistance | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
Vibration resistance | 10 to 500 Hz frequency, 1.5 mm 0.059 in (10 G max.) double amplitude in X, Y and Z directions for two hours each |
Shock resistance | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each |
Material | Enclosure: PBT (Mounting part: PEI) Lens cover: Acrylic |
Cable | 0.1 mm2, single core two parallel shielded cables, 2 m 6.562 ft long (Connector for amplifier attached) (Note) Cable cannot be extended. |
Weight | Net weight: 30 g approx Gross weight: 40 g approx |
Accessory | Warning label: 1 set (Labels are written in Japanese, English and Chinese for compliance with various standards.) |