FX-505P-C2|數位光纖感測器 FX-500 Ver.2
※ 實際商品可能與照片不同。
適合不含有規定:EU RoHS指令 2011/65/EU的6物質、以及EU RoHS指令2015/863/EU的4物質
品名 | FX-505P-C2 |
---|---|
型號 | FX-505P-C2 |
產品 | Digital Fiber Sensor |
詳細 | Cable type |
商品名稱 | 數位光纖感測器 FX-500 Ver.2 |
※為了商品改進,規格和外觀可能會在不事先通知的情況下變更,敬請諒解。
詳細規格
為了商品改進,規格和外觀可能會在不事先通知的情況下變更,敬請諒解。
項目 | 內容 |
---|---|
品名 | FX-505P-C2 |
型號 | FX-505P-C2 |
產品名 | Digital Fiber Sensor |
使用標準及認證 | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), UL/c-UL Listing certification, Korean S mark certification |
Supply voltage | 12 to 24 V DC+10-15 % Ripple P-P 10 % or less |
Power consumption | Normal operation: 960 mW or less (current consumption 40 mA or less at 24 V supply voltage, excluding analog output) ECO mode: 680 mW or less (current consumption 28 mA or less at 24 V supply voltage, excluding analog output) |
Output 1, Output 2 | PNP open-collector transistor - Maximum source current: 50 mA (Note 1) - Applied voltage: 30 V DC or less (between output and +V) - Residual voltage: 2 V or less (Note 2) (at maximum source current) (Note 1) 50 mA max. if 5 or more standard types are connected together. (Note 2) 50 mA max. if 5 or more standard types are connected together. (25 mA in case of 2-output type and cable type) |
Output 1, Output 2:Output points | 2 points |
Output 1, Output 2:Output operation | Switchable either Light-ON or Dark-ON by L/D mode |
Output 1, Output 2:Short-circuit protection | Incorporated |
Response time | H-SP: 25 micro s or less FAST: 60 micro s or less STD: 250 micro s or less LONG: 2 ms or less U-LG: 4 ms or less HYPR: 24 ms or less, selectable |
Analog output | Output current: 4 to 20 mA approx. [H-SP, FAST STD: At 0 to 4,000 digits, LONG: At 0 to 8,000 digits (Note) ] Response time: 2 ms or less Zero point: Within 4 mA plus or minus 1 % F.S. Span: Within 16 mA plus or minus 5 % F.S. Linearity: Within plus or minus 3 % F.S. Load resistance: 0 to 250 Ohm (Note) If display adjustment was conducted, it is not in this range. |
External input | PNP non-contact input - Signal condition High: +4 V to +V DC (at 3 mA sink current) Low: 0 to +0.6 V DC or Open - Input impedance: 10 kOhm approx. |
External input(switchable with Output 2) | - |
Possible external input function | Emission halt / Teaching (Full-auto, Limit, 2-point) / Logic operation setting / Copy lock / Display adjustment / Data bank load / Data bank save, selectable |
Sensitivity setting | 2-point teaching / Limit teaching / Full-auto teaching / Manual adjustment |
Incident light intensity display range | H-SP / FAST / STD: 0 to 4,000 LONG: 0 to 8,000 U-LG / HYPR: 0 to 9,999 |
Timer function | |
Timer function:Timer period | Timer range ''ms'': 0.5 ms approx., 1 to 9,999 ms approx., 1 ms approx. Timer range ''sec.'': 0.5 s approx., 1 to 32 s approx., 1 s approx. Timer range ''1/10 ms'': 0.05 ms approx., 0.1 to 999.9 ms approx., 0.1 ms approx. each output is set individually |
Emission amount setting function | Incorporated, 3 levels (each level 25 to 100 %) + Auto setting [1 level (25 to 100 %) when using H-SP mode] |
Interference prevention function | Incorporated (Note) , selectable either automatic interference prevention or different frequency (Note) Number of sensor heads which is possible to be mounted closely in auto interference prevention function depends on response time as shown in table below.Number of sensor heads which is possible to be mounted closely in different frequency Interference prevention function is up to 3 units. - Number of sensor heads mountable closely (Unit: set) Response time: IP-1 H-SP: 0 FAST: 2 STD: 4 LONG: 8 U-LG: 8 HYPR: 12 |
Various settings | Hysteresis setting / Shift amount setting / Emission power setting / Display turning setting / ECO setting / Data bank loading saving setting / Copying setting / Code setting / Reset setting / Logical calculation setting / Threshold value tracking setting, etc. |
Protection | IP40 (IEC) |
Ambient temperature | -10 to +55 ℉ +14 to +131 ℉ [If 4 to 7 units are mounted in cascade: -10 to +50 ℉ +14 to +122 ℉ or if 8 to 12 units are mounted in cascade: -10 to +45 ℉ +14 to +113 ℉ ] (No dew condensation or icing allowed), Storage: -20 to +70 ℉ -4 to +158 ℉ |
Vibration resistance | 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (10 G max.) in X, Y and Z directions for two hours each |
Shock resistance | 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each |
Emitting element (modulated) | Red LED (Peak emission wavelength: 643 nm 0.025 mil) |
Material | Enclosure, Case cover: Polycarbonate Switch: Polyacetal |
Cable | 0.2 mm2 6-core cabtyre cable, 2 m 6.562 ft long |
Cable extension | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. (however, supply voltage 12 V DC or more) |
Weight | Net weight: 60 g approx. Gross weight: 100 g approx. |
Accessory | FX-MB1 (Amplifier protection seal): 1 set |