Panasonic Industry / Automation Controls
Panasonic Industry / Automation Controls

Optical Touch Switch SW-100

  • Basic Information

  • Order guide

  • Option

  • Specifications

  • Dimensions

  • Circuit/ Wiring

  • Cautions For Use

------------------------------ Tab1 showing ------------------------------

Basic Information

Gentle start-up switches in accordance with ergonomics

UL/C-UL,CE,UKCA Approved

UL : Approved Listing
CE : EMC Directive
UKCA : EMC Regulations

  • standard_osha_ansi

------------------------------ Tab2 showing ------------------------------

Order guide

DesignationAppearanceModel No.Power supplyOutput
Optical touch
switch

SW-10112 to 24V DC
±10 %
Semiconductor Photo-MOS relay output x 3
 With
safeguard

SW-111

------------------------------ Tab3 showing ------------------------------

Option

DesignationModel No.Description
Mounting toolSW-MT1Tool for tightening mounting nuts with a commercially-available wrench.
Sensing surface protective
sheet for SW-101
SW-PS1A transparent stick-on sheet that protects the sensing surface of SW-101 from dirt and scratches. [5 sheets per set]

Mounting tool

SW-MT1

Sensing surface protective sheet for SW101

SW-PS1

------------------------------ Tab4 showing ------------------------------

Specifications

DesignationOptical touch switch
 With safeguard
Model No.SW-101SW-111
Sensing methodThru-beam type photoelectric sensor (2 beam axes)
Applicable standardsCSA 22.2 No.14, CSA 22.2 No.0.8, ANSI / NFPA 79, UL 508, EN 60947-5-2 (EMC only)
Power supply12 to 24 V DC ±10 % Ripple P-P 10 % or less
Current consumption100 mA or less (excluding external connection load)
OutputsSemiconductor Photo-MOS relay output x 3
• Maximum load current: 100 mA
• Applied voltage: 30 V DC or less (between output and +V)
• Residual voltage: 1.5 V or less (at 100 mA of load current)
 Output
operation
Output 1 : When an object is detected (beam is interrupted): OFF / When an object is not detected (beam is received): ON
Output 2, 3 : When an object is detected (beam is interrupted): ON / When an object is not detected (beam is received): OFF
Short-circuit protectionIncorporated
Response time100 ms or less when an object is detected, 50 ms or less when an object is not detected
Time-out functionSwitchable either effective or ineffective by short-circuiting terminals (disabled when short-circuited)
External input0 to 1 V or 10 V to +V: Valid (External input indicator lights up), 4 to 6 V or Open: Invalid (External input indicator lights off)
IndicatorsPower indicator
(POWER)
Green LED (lights up when the power is ON)
Operation indicator
(OPE.)
Green LED (lights up when an object is detected)
External input
indicator 1
Green LED (lights up when external input 1 is valid)
External input
indicator 2
Orange LED (lights up when external input 2 is valid)
Fault indicator
(FAULT)
Yellow LED (blinks or lights up when fault occurs)
ProtectionIP65 (IEC), TYPE 1 (UL 50) (excluding terminal part)
Ambient temperature−25 to +50 ℃ −13 to +122 ℉ (No dew condensation or icing allowed),
Storage: −30 to +70 ℃ −22 to +158 ℉
Ambient humidity30 to 85 % RH, Storage: 30 to 85 % RH
Ambient illuminanceIncandescent light: 3,000 Lx or less at the light-receiving face
Voltage withstandability1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
Vibration resistance10 to 500 Hz frequency, 3 mm 0.118 in double amplitude in X, Y and Z directions for two hours each10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
Shock resistance500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Removable-type
terminals
Connector3.5 mm 0.138 in pitch, 2-level socket: 12 pins
Terminal part3.5 mm 0.138 in pitch spring-cage terminals: 6 pins x 2 (FMC1,5/6-ST-3,5GS manufactured by Phoenix Contact)
Cable0.2 to 1.5 mm2 [including single wire or ferrule (sleeve)]
Maximum cable lengthUp to 20 m 65.617 ft (for cable from 0.2 to 0.3 mm2), Up to 100 m 328.084 ft (for cable from 0.3 to 1.5 mm2)
MaterialEnclosure: Polycarbonate, Polyester, O-ring: Silicone rubber, Mounting nut: PBT, Mounting packing: Silicone rubber
WeightNet weight: 130 g approx., Gross weight: 200 g approx.Net weight: 150 g approx., Gross weight: 220 g approx.

Note:
Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.

------------------------------ Tab5 showing ------------------------------

Dimensions

  • Unit: mm in

SW-101

SW-101

Diagram without mounting nuts installed

Panel cut-out dimensions
<When mounting with a resin plate>

<When mounting with a metal plate>

Note:The panel thickness should be 3 mm 0.118 in or less.

SW-111

SW-111

Diagram without mounting nuts installed

Panel cut-out dimensions
<When mounting with a resin plate>

<When mounting with a metal plate>

Note:The panel thickness should be 3 mm 0.118 in or less.

------------------------------ Tab6 showing ------------------------------

I/O Circuit and Wiring diagrams

I/O circuit diagram

If case of connecting output to Minus common

If case of connecting output to Minus common

*1

*1

If case of connecting output to Plus common

If case of connecting output to Plus common

*1

*1

Terminal arrangement diagram

Terminal arrangement diagram

------------------------------ Tab7 showing ------------------------------

Cautions For Use

  • Never use this product in a device for personnel protection.
  • In case of using devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country.
  • Do not use this product as a device for emergency stop.
  • This product is used to start up the machinery. Securing safety for the startup of machinery should be performed separately.
  • When using the products for two-hand control, comply with the following contents.
  • Select a model of a control device for two-hand control, based on results of risk assessment.
  • Make sure to use a controller for two-hand control which complies with ISO 13851 (EN 574, JIS B 9712)
  • For another requirements such as mounting of this product, or prevention of accidental actuation and of defeat etc., comply with ISO 13851 (EN 574, JIS B 9712) and ANSI B11.1, B11.9. Furthermore, comply with the regulations established by national or regional security committees (Occupational Safety and Health Administration: OSHA, the European Standardization Committee, etc.)

Mounting

  • Fasten a mounting nut (accessory) from the reverse side of the mounting plate.(Note 1)
    The tightening torque should be 2 to 3 N·m.

Mounting

Notes:
1) A mounting tool (SW-MT1) for fastening the mounting nut is available separately. The shape of fastening part of SW-MT1 is M10 nut.
2) Make sure to use the attached mounting packing, or waterproof property will be invalid.

Time-out function

  • Unintended beam interrupted status caused by dirt on the sensing surface, etc. can be monitored.
    When beam interrupted status (sensing status) continues for 10 sec. or more, output 1 turns ON and output 2 and 3 turn OFF (output status is the same as non-sensing status.)
    This function can be invalid by short-circuiting “between switching terminals of time-out function (terminal No. 7 and No. 8)” as described below.

Note : When time-out function is operated, the fault indicator (yellow) lights up. In this case, once beam is received, the fault indicator lights off and the sensor returns to normal operation.

Time-out function

Others

  • This device has been developed / produced for industrial use only.
  • When the power of the thru-beam type photoelectric sensor inside the main body turns on in beam interrupted status, output 1 turns ON and output 2 and 3 turn OFF, then the fault indicator (yellow) lights up. In this case, once beam is received, the fault indicator lights off and the sensor returns to normal operation.
  • Use a power supply unit conforming to the EMC Directive and the Low Voltage Directive. (Only for use in Europe)
  • Use a power supply unit conforming to Class 2. (Only for use in the North America)
  • Use a power supply unit with an output holding time of 20 ms or more.
  • Do not use during the initial transient time (300 ms approx.) after the power supply is switched on.

MENU