Panasonic Industry / Automation Controls
Panasonic Industry / Automation Controls

CC-Link Safety System Remote I/O Unit for Light Curtain SF-CL1T264T (Discontinued Products)

  • Discontinued Products

  • Specifications

  • Dimensions

  • Cautions For Use

Ⅾiscontinued

Last time buy (JST)

February 29, 2016

We are sorry, the products have been discontinued. 
Please refer to the details of the discontinued products and the recommended substitutes list below.

------------------------------ Tab1 showing ------------------------------

Discontinued Products

pic01

------------------------------ Tab2 showing ------------------------------

Specifications

DesignationCC-Link Safety system I/O unit
with connectors for light curtain
Model No.SF-CL1T264T
Connectable light curtainSF4B series
Applicable standardIEC / EN 61508 (SIL 3), EN ISO 13849-1 (JIS B 9705-1) (Category 4, PLe), UL 508
Unit power
(Note 2)
Supply voltage24 V DC ±10 % Ripple P-P 10 % or less
Current consumption140 mA or less (24 V DC, with all points ON)
Protective functionUnit power overvoltage / overcurrent protection function
Fuse0.8 A (Not replaceable)
Momentary power failure period10ms or less
Input
specifications
No. of input points (Note 3)Input of light curtain: 2 points (with interference prevention function),
Input of terminal block: 6 points (input terminals: 12 points)
Insulation methodPhotocoupler
Rated input voltage24 V DC
Rated input current4.6 mA approx.
Operating voltage range24 V DC ±10 % Ripple P-P 10 % or less
Max. simultaneous
input points
100 %
ON voltage / ON current15 V DC or more / 2 mA or more
OFF voltage / OFF current5 V DC or less / 0.5 mA or less
Input resistance5.6 kΩ approx.
Input typeNegative common
Response timeOFF -> ON: 0.4 ms or less (at 24 V DC, excluding connecting device)
ON -> OFF: 0.4 ms or less (at 24 V DC, excluding connecting device)
Safety remote station
input response time
32 ms or less + filter-out time (1 ms, 5 ms, 10 ms, 20 ms, 50 ms)
Output
specifications
No. of output points4 points (source + sink type), 2 points (source + source type)
Insulation methodPhotocoupler
Rated load voltage24 V DC
Rated load voltage range24 V DC ±10 % Ripple P-P 10 % or less
Max. load current0.5 A / point
Inrush current1.0 A (10 ms or less)
Leakage current0.5 mA or less
Residual voltage1.0 V DC or less
Protective functionOutput short-circuit protection function
Output typeSource + sink type, Source + source type
Response timeOFF -> ON: 0.4 ms or less (at 24 V DC)
ON -> OFF: 0.4 ms or less (at 24 V DC)
Safety remote station
input response time
32 ms or less
Surge protectionIncorporated (Zener diode)
External power
supply
(For external
device)
(Note 3)
Voltage24 V DC ±10 % Ripple P-P 10 % or less
Current60 mA (24 V DC, with all points ON, excluding external load current)
Protective functionExternal power supply overvoltage / overcurrent protection function
Fuse8 A (Not replaceable)
Wiring method for common16 input points / common, 4 output points / common (Terminal block 2-wire type)
Common currentMax. 4 A (Total of inputs and outputs)
No. of stations occupied1 station
No. of access to nonvolatile memory1012 times
Safety refresh response processing38 ms
Excess voltage categoryII
Pollution degree2
ProtectionIP20
Ambient temperature0 to +55 ℃ +32 to +131 ℉ (No dew condensation), Storage: -40 to +75 ℃ -40 to +167 ℉
Ambient humidity5 to 95 % RH, Storage: 5 to 95 % RH
Dielectric withstand voltage500V AC between all external DC terminals and ground, for 1 minute
Insulation resistance10 MΩ or more between all external DC terminals and ground, by a 500 V DC insulation resistance tester
Vibration resistance / Shock resistanceConforming to JIS B 3502, IEC 61131-2
MaterialEnclosure: ABS
External connection systemTerminal block, 2 crimp-style terminals or less
Cable0.3 to 2.0 mm2
Applicable crimp-style terminalRAV1.25-3 (Conforming to JIS B 2805) (Applicalbe wire size: 0.3 to 1.25 mm2)
WeightNet weight: 0.7 kg approx.

Notes:
1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature +20 ℃ +68 ℉.
2) The power supply connected to this product must satisfy the following conditions:
1 SELV (Safety Extra Low Voltage) : Reinforced insulated from hazardous potential part (48 V or more)
2 Compliance with the LVD (Low Voltage Directive)
3 Output voltage within 21.6 V to 26.4 V DC (Ripple P-P: 10 % or less.)
3) Total number of input points is 8 points, and use 2 points for control output (OSSD 1, 2) of 2 light curtains. Two inputs terminals are assigned for each input since dual wiring is supported.

------------------------------ Tab3 showing ------------------------------

Dimensions

  • Unit: mm in

------------------------------ Tab4 showing ------------------------------

Cautions For Use

  • When installing this product to a control panel, provide clearance of at least 60 mm 2.362 in between the unit's top / bottom and any other structure or component to ensure proper airflow and to make unit replacement easy.