Safety Relay Unit for PNP Output (Equivalent) Type Light Curtain SF-AC (Discontinued Products)

  • Discontinued Products

  • Specifications

  • Dimensions

  • Cautions For Use

Ⅾiscontinued

Last time buy (JST)

September 30, 2019

We are sorry, the products have been discontinued. 
Please refer to the details of the discontinued products and the recommended substitutes list below.

------------------------------ Tab1 showing ------------------------------

Discontinued Products

pic01

------------------------------ Tab2 showing ------------------------------

Specifications

Model No.SF-AC
Connectable
light curtains
PNP output type light curtains and Safety devices (SG-B1/A1/B2 series) manufactured by Panasonic Industry
Applicable standardsEN 60947-5-1, EN ISO 13849-1(Category 4,PLe), EN ISO 13849-2, IEC 60947-5-1, ISO 13849-1(Category 4, PLe), ISO 13849-2, JIS B 9705-1(Category 4), ANSI/UL 508, CAN/CSA C22.2 No.14, OSHA1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06
Control categoryISO 13849-1 compliance up to Category 4
Supply voltage24 V DC ± 10 % Ripple P-P 10 % or less
Power consumption1.7 W approx. (at 24 V DC) (without any connected devices)
Power supply
for light curtain
24 V DC ± 10 %
Fuse (power supply)Hybrid fuse, triggering current: 1.1 A or more, Reset after power down
OSSD inputPNP transistor 2 inputs (S1, S2)
Enabling pathNO contact × 3 (13-14, 23-24, 33-34)
 Utilization categoryAC-15, DC-13 (EN 60947-5-1)
Rated operational
current(Ie)(Note 2) /
Rated operational
voltage
6 A / 30 V DC, 6 A / 230 V AC, resistive load
Contact material /
contacts
AgSnO, Self cleaning, positively driven
Contact resistance100 mΩ or less (initial value)
Fuse6 A (slow blow)
Mechanical lifetime10 million times (switching frequency 180 times/min.)
Electrical lifetime100,000 times (switching frequency 20 times/min, rated load)
B10dAt min.load:20,000,000 / At max.load :400,000 (ISO 13849-1)
Pick-up delay40 ms or less (Automatic reset), 50 ms or less (Manual reset)
Drop-out delay10 ms or less
Auxiliary outputNC contact × 1 (41-42)
 Switching current1 A / 24 V DC
Fuse1 A (slow blow)
Alarm output (Note 3)NC contact × 1 (51-52) (Non-safety contact, related to input “Alarm in”)
 Switching currentMax. 1 A / 24 V DC, Min. 5 mA / 24 V DC
Fuse1 A (slow blow)
IndicatorsPowerGreen LED (lights up when the power is supplied)
Internal circuit
operation(Ui)
Green LED (lights up when both conditions are present: unit is powered up and hybrid fuse is at normal state)
Relay operation
(K1 / K2)
Green LED × 2 (lights up when enabling contacts are closed)
Test input (Test)Yellow LED (lights up when X11-X12 is opened)
External relay
monitor function
Incorporated
Trailing edge functionIncorporated
Test input polarity
selection function
Incorporated (Selectable PNP or NPN test input polarity by internal switch)
Excess voltage categoryIII
Rated impulse-withstand
voltage (Uimp)
4 kV
Pollution degree2
Environmental
resistance
Degree of
protection
Enclosure : IP40, Terminal : IP20
Ambient
temperature
-10 to +55 ℃ +14 to +131 ℉, Storage: -10 to +55 ℃ +14 to +131 ℉
Ambient
humidity
35 to 85 % RH, Storage: 35 to 85 % RH
Vibration
resistance
10 to 55 Hz frequency, 0.35 mm 0.014 in amplitude in X, Y, Z directions for three times each (in power OFF state)
Shock
resistance
15 G (150 m/s2 approx.) Effective impulse time 11ms
MaterialEnclosure: Polycarbonate
Connection terminalRemovable European terminal
 Tightening torque0.6 N·m
Wiring cable0.2 to 2.5 mm2 [including single wire or ferrule (sleeve)]
MountingComplies with 35 mm width DIN rail (EN 50022)
WeightNet weight: 400 g approx.

Note 1 : Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.

Note 2 : The rated operational current (le) varies depending on the ambient temperature. Refer to the below figure.

Note 3 : The alarm output is "open" when the alarm input from the light curtain is ON.

------------------------------ Tab3 showing ------------------------------

Dimensions

  • Unit: mm in

------------------------------ Tab4 showing ------------------------------

Cautions For Use

  • Note that SF-AC cannot be connected to the NPN output (equivalent) type light curtain.

Wiring

Please install and connect ferrule (stick) terminal when the lead wire of the connected equipment is a twisted wire.
Please do not connect the twisted wire directly with the terminal.
Tighten the wiring to the wiring terminal block at tightening torque of 0.6 N m.

Others

The seal as shown in the drawing on the right is stuck to the engagement point of unit. When the seal is peeled off or broken, this equipment will not be certified as ‘Safety equipment’.

SAFETY SEAL

Functional description

Functional description

Derating

Rated operation current (le) of enabling path changes depending on ambient temperature.

Derating