SQ4-C11|Safety Liquid Leak Sensor [Control Category 4 PLe SIL3] SQ4
Download
*Photo may vary from actual product.
This product has been confirmed that it does not contain the 6 substances specified in EU RoHS Directive 2011/65/EU and the 4 substances specified in 2015/863/EU.
Product Number | SQ4-C11 |
---|---|
Part Number | SQ4-C11 |
Product | Safety Liquid Leak Sensor [Control Category 4 PLe SIL3] |
Details | Controller |
Product Name | Safety Liquid Leak Sensor [Control Category 4 PLe SIL3] SQ4 |
*Specifications and design of the products are subject to change without notice for the product improvement.
Spec Detail
Specifications and design of the products are subject to change without notice for the product improvement.
Item | Specifications |
---|---|
Part Number | SQ4-C11 |
Product Number | SQ4-C11 |
Products Name | Safety Liquid Leak Sensor [Control Category 4 PLe SIL3] |
Product details | Controller |
The price of the product | Please contact our office |
Applicable standards:International standard | ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3) |
Applicable standards:Japan | JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3) |
Applicable standards:Europe | EN 55011 Class A, EN 61000-6-2, EN 50178, EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3) (Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate. |
Applicable standards:North America | ANSI/UL 508, CAN/CSA C22.2 No.14 (Note) With regards to the standards in the US, under the US regulation 29 CFR 1910.7, TÜV SÜD America, a Nationally Recognized Testing Laboratory (NRTL) certified by OSHA, has certified with the safety certificate based on UL / ANSI standards. With regards to the standards in Canada, under the safety regulations based on CEC (Canadian Electric Code), TÜV SÜD America, a Certification Body accredited by SCC, has certified with the safety certificate based on CSA standards. |
Applicable standards:South Korea | S1-G-1, S2-W-5, KS C IEC 60947-5-2 |
Applicable standards:SEMI | Conforming to SEMI-S2-0310a |
Power voltage | 24 V DC+10-15 % Ripple P-P 10 % or less |
Current consumption | 200 mA or less |
Control outputs (OSSD 1, OSSD 2) | PNP open-collector transistor / NPN open-collector transistor (switch method) [Selecting PNP output] - Maximum source current: 200 mA - Applied voltage: Same as power voltage (between control output to +V) - Residual voltage: 2.5 V or less (at 200 mA source current) [Selecting NPN output] - Maximum sink current: 200 mA - Applied voltage: Same as power voltage (between control output to 0 V) - Residual voltage: 2.0 V or less (at 200 mA sink current) |
Control output(OSSD 1, OSSD 2):Response time | 20 ms or less (excluding the response time of the sensor) |
Control outputs (OSSD 1, OSSD 2):Operation mode | ON when normal condition or initial detection, OFF when detection leakage or wrong installation |
Control output(OSSD 1, OSSD 2):Protection circuit (Short-circuit protection) | Incorporated |
Sensor monitor output(AUX1, 2, 3, 4, Non-safety output) | PNP open-collector transistor / NPN open-collector transistor (switch method) [Selecting PNP output] - Maximum source current: 60 mA - Applied voltage: Same as power voltage(between sensor monitor output to +V) - Residual voltage: 2.5 V or less (at 60 mA source current) [Selecting NPN output] - Maximum sink current: 60 m A - Applied voltage: Same as power voltage(between sensor monitor output to 0 V) - Residual voltage: 2.0 V or less (at 60 mA sink current) |
Sensor monitor output(AUX1, 2, 3, 4, Non-safety output):Response time | 100 ms or less (excluding the response time of the sensor) |
Sensor monitor output(AUX1, 2, 3, 4, Non-safety output):Operation mode(Output operation) | ON when normal condition, OFF when initial detection or accidental leakage |
Sensor monitor output(AUX1, 2, 3, 4, Non-safety output):Protection circuit (Short-circuit protection) | Incorporated |
Lockout output | OFF for lockout (Rating: Same as sensor monitor output) |
Auxiliary output | Negative logic output of control output 1 / 2 (OSSD 1 / 2) (Rating: Same as sensor monitor output) [Auxiliary output ON when control output 1 / 2 (OSSD 1/2) is OFF] |
Functions | Interlock / lockout cancel / Test input / External device monitor / Safety input / Control output polarity selection / Non-safety output polarity selection / Sensor connection number setting |
Protection | IP20 (IEC) (However, it should be in IP54 protection structure of control panel) |
Ambient temperature | -10 to +55 ℃ +14 to +131℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉ |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
PFHD | When PNP output is selected: 1.89 × 10-9 (when connecting 4 safety liquid leak sensors) When NPN output is selected: 1.80 × 10-9 (when connecting 4 safety liquid leak sensors) |
MTTFD | 100 years or more |
Material | Main unit case: PC + ABS (alloy) |
Weight | Net weight: 170 g approx Gross weight: 440 g approx |