SQ4-A22-N|Safety Liquid Leak Sensor [Control Category 4 PLe SIL3] SQ4
Download
*Photo may vary from actual product.
This product has been confirmed that it does not contain the 6 substances specified in EU RoHS Directive 2011/65/EU and the 4 substances specified in 2015/863/EU.
Product Number | SQ4-A22-N |
---|---|
Part Number | SQ4-A22-N |
Product | Safety Liquid Leak Sensor [Control Category 4 PLe SIL3] |
Details | Sensor [For chemical liquid] |
Product Name | Safety Liquid Leak Sensor [Control Category 4 PLe SIL3] SQ4 |
*Specifications and design of the products are subject to change without notice for the product improvement.
Spec Detail
Specifications and design of the products are subject to change without notice for the product improvement.
Item | Specifications |
---|---|
Part Number | SQ4-A22-N |
Product Number | SQ4-A22-N |
Products Name | Safety Liquid Leak Sensor [Control Category 4 PLe SIL3] |
Product details | Sensor [For chemical liquid] |
The price of the product | Please contact our office |
Sensing object | Sulfuric acid, Hydrochloric acid,Phosphoric acid, Ammonia, Fluorinert (Note 2), Galden (Note 2), Hydrofl uoric acid etc. (Note 3) (Note 1) Highly viscous liquid may not be stably detected. (Note 2) The agents mentioned above are examples. It may not be detected depending on viscosity the agent.Before using this device, check the detecting liquid and installation condition. (Note 3) Fluorinert is the world wide trademark of 3M. Galden is the registered trademark of Solvay. |
Power voltage | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
Current consumption | 30 mA or less |
Utilization category | DC-12, DC-13 |
Detection output(Leakage detection) | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: Same as the supply voltage (between detection output and 0 V) - Residual voltage: 2 V or less (at 50 mA sink current) |
Detection output(Leakage detection):Response time | 10 ms or less |
Detection output(Leakage detection):Output operation | ON when normal condition or initial detection, OFF when detection leakage or wrong installation |
Detection output(Leakage detection):Short-circuit protection | Incorporated |
Detection auxiliary output(Initial detection) | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: Same as the supply voltage (between detection auxiliary output and 0 V) - Residual voltage: 2 V or less (at 50 mA sink current) |
Detection auxiliary output(Initial detection):Response time | 50 ms or less |
Detection auxiliary output(Initial detection):Output operation | ON when normal condition, OFF when initial detection or accidental leakage |
Detection auxiliary output(Initial detection):Short-circuit protection | Incorporated |
Protection | IP65 / IP67 (IEC) |
Ambient temperature | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed) (Note) Storage: -10 to +55 ℃ +14 to +131 ℉ (Note) Liquid being detected should be also kept within the rated ambient temperature range. |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Emitting element | Infrared LED (modulated) |
Material | Enclosure: PFA |
Cable | 0.1 mm2 4-core PFA cabtyre cable, 2 m 6.562 ft long |
Weight | Net weight: 45 g approx Gross weight: 110 g approx |