SF-C11|Exclusive Control Unit for Safety Light Curtain SF-C10
Download
*Photo may vary from actual product.
This product has been confirmed that it does not contain the 6 substances specified in EU RoHS Directive 2011/65/EU and the 4 substances specified in 2015/863/EU.
Product Number | SF-C11 |
---|---|
Part Number | SF-C11 |
Product | Exclusive Control Unit for Safety Light Curtain |
Details | Connector connection type control unit |
Product Name | Exclusive Control Unit for Safety Light Curtain SF-C10 |
*Specifications and design of the products are subject to change without notice for the product improvement.
Spec Detail
Specifications and design of the products are subject to change without notice for the product improvement.
Item | Specifications |
---|---|
Part Number | SF-C11 |
Product Number | SF-C11 |
Products Name | Exclusive Control Unit for Safety Light Curtain |
Product details | Connector connection type control unit |
The price of the product | Please contact our office |
Connectable safety light curtains | SF4D series |
Applicable standards | EN 61496-1 (Type 4), EN 55011, EN ISO 13849-1:2015 (Category 4, , PLe), IEC 61496-1 (Type 4), ISO 13849-1:2015 (Category 4, PLe), JIS B 9704-1 (Type 4), JIS B 9705-1 (Category 4), ANSI/UL 61496-1 (Type 4), UL 1998 (Class 2) |
Applicable regulations | CE Marking (Machinery Directive, EMC Directive, RoHS Directive),UKCA Marking (Machinery Regulations, EMC Regulations, RoHS Regulations) |
Power voltage | 24 V DC ±10 % Ripple P-P 10 % or less |
Current consumption | 100 mA or less (without safety light curtain) |
Fuse rating | Built-in electronic fuse, Triggering current: 0.5 A or more, Reset after power down |
Enabling path | NO contact × 3 (13-14, 23-24, 33-34) |
Enabling path : Utilization | AC-15, DC-13 (IEC 60947-5-1) |
Enabling path : Rated operation voltage (Ue) / Rated operation current (le) | 30 V DC / 6 A, 230 V AC / 6 A, resistive load(For inductive load, during contact protection)Min. applicable load: 10 mA (at 24 V DC) (Note) : If several SF-C11 or SF-C13 units are being used in a line together, leave a space of 5 mm 0.197 in or more between each unit. If the units are touching each other, reduce the rated operating current for safety output in accordance with the ambient operating temperature as shown in the graphs below. |
Enabling path : Contact material / contacts | Silver tin oxide (AgSnO), self cleaning, positively driven |
Enabling path : Contact resistance | 100 mOhm or less (initial value) |
Enabling path : Contact protection fuse rating | 6 A (slow blow) |
Enabling path : Mechanical lifetime | 10,000,000 times or more (open/close frequency of 180 times/min) (Note:The life expectancy of the relay varies depending on the type of load, open / close frequency, ambient conditions and others.) |
Enabling path : Electrical lifetime | 100,000 times or more (open/close frequency of 20 times/min, 230 V AC, 3 A, using resistance load) (Note:The life expectancy of the relay varies depending on the type of load, open / close frequency, ambient conditions and others.) |
Pick-up delay(Auto reset / Manual reset) | 80 ms or less / 90 ms or less |
Response time | 10 ms or less |
Auxiliary outputs | Safety relay contact (NC contact) × 1 (41-42) (Related to enabling path) |
Auxiliary output:Rated operation voltage / current | 24 V DC / 2 A, Min. applicable load: 10 mA (at 24 V DC) |
Auxiliary output:Contact protection fuse rated | 2 A (slow blow) |
Semiconductor auxiliary output(AUX) | PNP open-collector transistor • Maximum source current: 60 mA • Applied voltage: same as supply voltage (between the auxiliary output and +V) • Residual voltage: 2.3 V or less (at 60 mA source current) • Leakage current: 2 mA or less NPN open-collector transistor • Maximum sink current: 60 mA • Applied voltage: same as supply voltage (between the auxiliary output and 0V) • Residual voltage: 1.5 V or less (at 60 mA sink current) • Leakage current: 2 mA or less |
Semiconductor auxiliary output(AUX):Output operation | Related to auxiliary output of safety light curtain |
Excess voltage category | II |
Indicators:Power supply (Ui) | Green LED (lights up when the power is ON) |
Indicators : Enabling path (OUT) | Green LED (lights up when the enabling contacts are closed) |
Indicators:Interlock (INTER_LOCK) | Yellow LED (lights up when safety output is opened) |
Indicators:Fault (FAULT) | Yellow LED (blinks when fault occurs) |
External relay monitor function | Incorporated |
Trailing edge function | Incorporated |
Polarity selection function | Incorporated (Sliding switch allows selection of plus/minus ground) Minus ground: Correspond to PNP output safety light curtain Plus ground: Correspond to NPN output safety light curtain (Note):Please switch the sliding switch to the PNP side for minus ground and to the NPN side for plus ground. |
Pollution degree | 2 |
Environmental resistance:Degree of protection | Enclosure: IP40 Terminal: IP20 |
Environmental resistance:Ambient temperature | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 ℃ -13 to +158℉ |
Environmental resistance:Ambient humidity | 30 to 85 % RH, Storage: 30 to 95 % RH |
Environmental resistance:Vibration resistance | Malfunction resistance 10 to 55Hz, 0.35 mm 0.014 in double amplitude 20 times each in X, Y, and Z directions |
Enclosure material | ABS |
Connection terminal | Detachable spring-cage terminal |
Weight | Net weight: 320 g approx. |