GX-30MLU|Cylindrical Inductive Proximity Sensor GX-U/GX-FU/GX-N(Discontinued)
Download
Discontinued
Last time buy (JST)
*Photo may vary from actual product.
This product has been confirmed that it does not contain the 6 substances specified in EU RoHS Directive 2011/65/EU and the 4 substances specified in 2015/863/EU.
Spec Detail
Item | Specifications |
---|---|
Part Number | GX-30MLU |
Product Number | GX-30MLU |
Products Name | DC 3-wire Cylindrical Inductive Proximity Sensor |
Product details | DC 2-wire type |
The price of the product | Please contact our office |
Max. operation distance | 22 mm 0.866 in plus or minus 10 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. |
Stable sensing range | 0 to 17.6 mm 0 to 0.693 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. |
Standard sensing object | Iron sheet 70 × 70 × t 1 mm 2.756 × 2.756 × t 0.039 in |
Hysteresis | 20 % or less of operation distance (with standard sensing object) |
Supply voltage | 12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less |
Current consumption | 0.8 mA or less (Note) It is the leakage current when the output is in the OFF state. |
Output | Non-contact DC 2-wire type - Load current: 3 to 70 mA (Note 1) - Residual voltage: 3 V or less (Note 2) (Note 1) The maximum load current varies depending on the ambient temperature. (Note 2) When the cable is extended, the residual voltage becomes larger. |
Output:Short-circuit protection | Incorporated |
Max. response frequency | 220 Hz |
Operation indicator | Normally closed type: Orange LED (lights up when the output is ON) |
2-color indicator | Lights up in green under stable sensing condition lights up in orange under unstable sensing condition |
Protection | IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.Please check the resistivity of the sensor against the cutting oil you are using beforehand.) |
Ambient temperature | -25 to +70 ℃ -13 to +158℉, Storage: -30 to +80 ℃ -22 to +176℉ |
Ambient humidity | 45 to 85 % RH, Storage: 35 to 95 % RH |
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
Insulation resistance | 50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure |
Vibration resistance | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each |
Shock resistance | 1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each |
Sensing range variation:Temperature characteristics | Over ambient temperature range -25 to +70 ℃ -13 to +158℉ : within plus or minus10 % of sensing range at +20 ℃ +68℉ |
Sensing range variation:Voltage characteristics | Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage |
Material | Enclosure: Brass (Nickel plated) Sensing part: Nylon Indicator part: Nylon |
Cable | 0.3 mm2 2-core oil, heat and cold resistant cabtyre cable, 2 m 6.562 ft long |
Cable extension | Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable. |
Weight | Net weight:220 g approx. |
Accessories | Nut: 2 pcs., Toothed lock washer: 1 pc. |