Product Number | SC-GU1-485 |
---|---|
Part Number | SC-GU1-485 |
Product | Upper Communication Unit for Digital Sensors |
Details | Main unit |
Product Name | Upper Communication Unit for Digital Sensors SC-GU1-485 |
*Specifications and design of the products are subject to change without notice for the product improvement.
Spec Detail
Specifications and design of the products are subject to change without notice for the product improvement.
Item | Specifications |
---|---|
Part Number | SC-GU1-485 |
Product Number | SC-GU1-485 |
Products Name | Upper Communication Unit for Digital Sensors |
Product details | Main unit |
The price of the product | Please contact our office |
Applicable sensor | FX-501(P), FX-502(P), LS-403, DPS-401(P), DPS-402(P), SC-T1JA |
Number of units connectable | Max. 16 units of digital sensor / analog input unit per SC-GU1-485(Note:The maximum number of units is 12 for configurations including either the FX-501(P)/502(P) or LS-501(P).) |
Connectable nodes | Max. 31 nodes |
Supply voltage | 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
Current consumption | 45 mA or less (SC-GU1-EU: 10 mA or less) |
Communication method | Two-wire half duplex communication |
Communication speed | 57,600 bps / 38,400 bps / 19,200 bps / 9,600 bps, Selectable by DIP switch |
Synchronization method | Asynchronous communication method |
Electrical characteristic | Conforming to EIA RS-485 |
Total extension length | Communication cable: 100 m 328.084 ft or less [SC-GU1-485 (termination) to PLC] Power supply cable: Less than 10 m 32.808 ft |
Indicators:Power (POWER) | Green LED (Lights up when the power is ON) |
Indicators:Communication (COMM) | Green LED (Lights up during communication) |
Indicators:Upper communication error (C.Err) | Red LED [Blinks when communication error between PLC (Programmable Logic Controller) and Master or Master and Slave, or command error occurs] |
Indicators:Lower communication error (S.Err) | Red LED (Blinks when communication error between the main unit and sensors occur) |
Ambient temperature | –10 to +55 ℃ +14 to +131 ℉ (If 4 to 7 units are connected in cascade: –10 to +50 ℃ +14 to +122 ℉, if 8 to 16 units are connected in cascade: –10 to +45 ℃ +14 to +113 ℉) (No dew condensation or icing allowed), Storage: –20 to +70 ℃ –4 to +158 ℉ |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
Insulation resistance | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure |
Vibration resistance | 10 to 150 Hz frequency, 0.75 mm double amplitude or maximum acceleration 49 m/s2 in X, Y, and Z direction for 2 hours each |
Shock resistance | 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each |
Material | Enclosure: Heat-resistant ABS Connector cap: silicone rubber |
Weight | Net weight : 35 g approx. (SC-GU1-EU: 10 g approx.) Gross weight: 120 g approx. |
Accessory | SC-GU1-EU (End unit): 1 pc. CN-73-C2 [Quick-connection cable (cable length 2 m 6.562 ft)]: 1 pc. SC-GU1-CC02 [Link cable (cable length 0.2 m 0.656 ft)]: 1 pc. |