DPS-401|Head-separated Dual Display Digital Pressure Sensor [For Gas] DPS-400 / DPH-100
Download

*Photo may vary from actual product.
This product has been confirmed that it does not contain the 6 substances specified in EU RoHS Directive 2011/65/EU and the 4 substances specified in 2015/863/EU.
Product Number | DPS-401 |
---|---|
Part Number | DPS-401 |
Product | Head-separated Dual Display Digital Pressure Sensor [For Gas] |
Details | Controller |
Product Name | Head-separated Dual Display Digital Pressure Sensor [For Gas] DPS-400 / DPH-100 |
*Specifications and design of the products are subject to change without notice for the product improvement.
Spec Detail
Specifications and design of the products are subject to change without notice for the product improvement.
Item | Specifications |
---|---|
Part Number | DPS-401 |
Product Number | DPS-401 |
Products Name | Head-separated Dual Display Digital Pressure Sensor [For Gas] |
Product details | Controller |
CE marking directive compliance | EMC Directive, RoHS Directive |
Applicable sensor head | Compound pressure : DPH-101□ Vacuum pressure : DPH-103□ |
Rated pressure range | Compound pressure : -100.0 to +100.0kPa Vacuum pressure : 0 to -101kPa |
Display / set pressure range | Compound pressure : -199.9 to +199.9 kPa Vacuum pressure : +101.3 to -101.3 kPa |
Supply voltage | 12 to 24 V DC ±10 % Ripple P-P 10 % or less |
Power consumption | Normal operation : 650 mW or less (Current consumption 25 mA or less at 24 V supply voltage) ECO mode : 500 mW or less (Current consumption 20 mA or less at 24 V supply voltage) (Note): Excluding current consumption of the applicable pressure sensor head. |
Sensor head supply voltage | Same as supply voltage |
Sensor head input | Input voltage range : 1 to 5 V DC (over rated pressure range) |
Comparative output | NPN open-collector transistor ・Maximum sink current : 50 mA (Note 1) ・Applied voltage : 30 V DC or less (between comparative output and 0 V) ・Residual voltage : 1.5 V or less (Note 2) [at 50 mA (Note 1) sink current] (Note 1): 25 mA max. if 5 or more controllers are connected together. (Note 2): In case of using the quick-connection cable (cable length : 5 m 16.404 ft)(optional) |
Comparative output:Output operation | NO / NC, selectable by jog switch |
Comparative output:Hysteresis | Minimum 0 digit, variable by hysteresis setting |
Comparative output:Repeatability | With compound pressure type connected : within ±0.2 % F.S. (±4 digits), With vacuum / positive pressure type connected : within ±0.2 % F.S. (±2 digits) |
Comparative output:Response time | 150 μs, 500 μs, 1 ms, 5 ms, 10 ms, 50 ms, 100 ms, 500 ms, selectable by jog switch |
Ambient temperature | -10 to +50℃ +14 to +122℉ (cascading 8 to 16 controllers : -10 to +45℃ +14 to +133℉)(No dew condensation or icing allowed), Storage : -20 to +70℃ -4 to +158℉ |
Ambient humidity | 35 to 85 % RH, Storage : 35 to 85 % RH |
Temperature characteristics | Over ambient temperature range -10 to +50℃ +14 to +122℉ : within ±0.5 % F.S. of pressure at +25℃ +77℉ |
Material | Enclosure : Heat-resistant ABS, Protective cover : Polycarbonate, Jog switch : ABS, MODE key : Acrylic |
Weight | Net weight : 20 g approx. |
Remark | ・Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20℃ +68℉. ・The cable for controller connection is not supplied as an accessory. Make sure to use the quick-connection cables (optional) given below. Main cable (4-core) : CN-74-C1 (cable length : 1m 3.281 ft), CN-74-C2 (cable length : 2 m 6.562 ft), CN-74-C5 (cable length : 5 m 16.404 ft) Sub cable (2-core) : CN-72-C1 (cable length : 1m 3.281 ft), CN-72-C2 (cable length : 2 m 6.562 ft), CN-72-C5 (cable length : 5 m 16.404 ft) ・The values specified above are applied only to the controller. |