DPC-101|Head-separated Dual Display Digital Pressure Sensor [For Gas] DPH-100 / DPC-100
Download

*Photo may vary from actual product.
This product has been confirmed that it does not contain the 6 substances specified in EU RoHS Directive 2011/65/EU and the 4 substances specified in 2015/863/EU.
Product Number | DPC-101 |
---|---|
Part Number | DPC-101 |
Product | Head-separated Dual Display Digital Pressure Sensor [For gas] |
Details | Controller |
Product Name | Head-separated Dual Display Digital Pressure Sensor [For Gas] DPH-100 / DPC-100 |
*Specifications and design of the products are subject to change without notice for the product improvement.
Spec Detail
Specifications and design of the products are subject to change without notice for the product improvement.
Item | Specifications |
---|---|
Part Number | DPC-101 |
Product Number | DPC-101 |
Products Name | Head-separated Dual Display Digital Pressure Sensor [For gas] |
Product details | Controller |
CE marking directive compliance | EMC Directive, RoHS Directive |
Type of pressure | Gauge pressure |
Rated pressure range | DPH-101□(Compound pressure): -100.0 to +100.0 kPa, DPH-102□(Positive pressure): 0 to +1.000 MPa, DPH-103□(Vacuum pressure): 0 to -101.0 kPa (Note) : It changes automatically according to the connected pressure sensor head. |
Set pressure range | DPH-101□(Compound pressure) : -199.9 to +199.9 kPa (-1.999 to +1.999 kgf/cm2, -19.98 to +19.98 psi, -1.999 to +1.999 bar, -1510 to +1537 mmHg, -59.4 to +60.5 inHg) DPH-102□(Positive pressure) : -1.050 to +1.050 MPa (-10.71 to +10.71 kgf/cm2, -152.2 to +152.2 psi, -10.50 to +10.50 bar) DPH-103□(Vacuum pressure) : +101.3 to -101.3 kPa (+1.033 to -1.033 kgf/cm2, +14.70 to -14.70 psi, +1.013 to -1.013 bar, +760 to -760 mmHg, +29.9 to -29.9 inHg) (Note) : It changes automatically according to the connected pressure sensor head. |
Supply voltage | 12 to 24 V DC ± 10 % Ripple P-P 10 % or less |
Power consumption | Normal operation : 960 mW or less (Current consumption 40 mA or less at 24 V supply voltage) ECO mode (STD) : 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage) ECO mode (FULL) : 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage) Excluding the current consumption of sensor head and analog output current |
Sensor head supply voltage | Same as supply voltage |
Comparative output | NPN open-collector transistor (2 outputs) ・Maximum sink current : 100 mA ・Applied voltage : 30 V DC or less (between comparative output and 0 V) ・Residual voltage : 2 V or less (at 100 mA sink current) |
Comparative output:Output operation | NO / NC, selectable by key operation |
Comparative output:Output modes | EASY mode / Hysteresis mode / Window comparator mode |
Comparative output:Hysteresis | Minimum 1 digit (variable)(however, 2 digits when using psi unit) |
Comparative output:Repeatability | With vacuum / positive pressure type connected : within ±0.2 % F.S. (±2 digits) With compound pressure type connected : within ±0.2 % F.S. (±4 digits) |
Comparative output:Response time | 0.5 ms, 1 ms, 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation |
Comparative output:Short-circuit protection | Incorporated |
Analog output | <Analog voltage output> ・Output current : 1 to 5 V DC ・Zero point : within 1 V ± 0.5 % F.S. (vacuum / positive pressure type) within 3 V ± 0.5 % F.S. (compound pressure type) ・Span : within 4 V ± 0.5 % F.S. ・Linearity : within ±0.1 % F.S. ・Output impedance : 1 kΩ approx. <Analog current output> ・Output current : 4 to 20 mA ・Zero point : within 4 mA ± 1 % F.S. (vacuum / positive pressure type) within 12 mA ± 1.5 % F.S. (compound pressure type) ・Span : within 16 mA ± 1.5 % F.S. ・Linearity : within ±0.1 % F.S. ・Load resistance : 250 Ω (max.). |
Inputs : Sensor head input | Input voltage range : 1 to 5 V DC (over rated pressure range) |
Inputs : External input (Auto-reference function/Remote zero-adjustment function) | ON voltage : +0.4 V DC or less OFF voltage : +5 to +30 V DC, or open Input impedance : 10 kΩ approx. Input time : 1 ms or more |
Display | 4 digits + 4 digits 3-color LCD display (Display refresh rate : 250 ms, 500 ms, 1,000 ms, selectable by key operation) |
Display : Displayable pressure range | Vacuum pressure : +5.1 to -101.3 kPa, Positive pressure : -0.050 to +1.020 MPa, Compound pressure : -101.3 to +105.0 kPa |
Operation indicator | Orange LED (Comparative output 1 operation indicator, comparative output 2 operation indicator : Lights up when each comparative output is ON) |
Protection | IP40 (IEC) |
Ambient temperature | -10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage : -10 to +60 ℃ +14 to +140 ℉ |
Ambient humidity | 35 to 85 % RH, Storage : 35 to 85 % RH |
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
Insulation resistance | 50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure |
Vibration resistance | 10 to 500 Hz frequency, double amplitude 3 mm 0.118 in or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each (when panel mounting bracket is mounted : 10 to 150 Hz frequency, double amplitude 0.75 mm 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each) |
Shock resistance | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each |
Temperature characteristics | Within ±0.5 % F.S. (ambient temperature range based on +20 ℃ +68 ℉) |
Material | Enclosure : PBT (glass fiber reinforced), LCD display : Acrylic, Mounting threaded part : Brass (nickel plated), Switch part : Silicone rubber |
Connecting method | Connector |
Cable length | Total length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. |
Weight | Net weight : 25 g approx. (excluding connector attached cable), Gross weight : 140 g approx. |
Accessories | CN-66A-C2 (Connector attached cable 2 m 6.562 ft), Pressure unit label : 1 set |
Remark | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉. The values specified above are applied only to the controller. |