GD-C3|Metal-sheet Double-feed Detector GD(Discontinued)
Download
Discontinued
Last time buy (JST)
*Photo may vary from actual product.
This product has been confirmed that it does not contain the 6 substances specified in EU RoHS Directive 2011/65/EU and the 4 substances specified in 2015/863/EU.
Spec Detail
Item | Specifications |
---|---|
Part Number | GD-C3 |
Product Number | GD-C3 |
Products Name | Metal-sheet Double-feed Detector |
Product details | Controller (Small object detection) |
The price of the product | please contact our office |
Type | Small object detection |
Supply voltage | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
Current consumption | 12 V DC: 700 mA or less, 24 V DC: 400 mA or less |
Outputs (OUT-1 , OUT-2 , ALM. , Answer-back ) | NPN open-collector transistor -Maximum sink current: 100 mA -Applied voltage: 30 V DC or less (between output and 0 V) -Residual voltage: 1 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current) |
Outputs (OUT-1 , OUT-2 , ALM. ,Answer-back ) : Output Operation : OUT-1 | OFF above the one-sheet threshold level |
Outputs (OUT-1 , OUT-2 , ALM. ,Answer-back ) : Output Operation : OUT-2 | OFF above the two-sheet threshold level |
Outputs (OUT-1 , OUT-2 , ALM. ,Answer-back ) : Output Operation : ALM. | OFF when an error occurs |
Outputs (OUT-1 , OUT-2 , ALM. ,Answer-back ) : Short-circuit protection | Incorporated |
Response time | 5 ms or less |
Set level storage function | Set values of eight channels stored |
Set level teaching function | Incorporated |
External setting function | Incorporated |
Indicators : Power | Green LED (lights up when the power is ON) |
Indicators : Self-diagnosis (ALM.) | Red LED (lights up during SET mode and when an error occurs during RUN mode) |
Indicators : Sensing mode (SENSE) | 2-color indicator (lights up green during normal sensing mode, but yellow during precise sensing mode) |
Indicators : OUT-1 | Green LED (lights up when OUT-1 is OFF, and blinks twice on completion of 0-ADJ. or SET-1 setting in SET mode) |
Indicators : OUT-2 | Red LED (lights up when OUT-2 is OFF, and blinks twice on completion of 0-ADJ. or SET-2 setting in SET mode) |
Indicators : Sensing level | Yellow LED x 1 and green LED x 6 (indicate the sensing level) |
Timer function | Approx. 50 ms fixed delay timer (switchable either effective or ineffective) |
Environmental resistance : Ambient temperature | -10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 C° -13 to +158 ℉ |
Environmental resistance : Ambient humidity | 45 to 85 % RH, Storage: 35 to 90 % RH |
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
Insulation resistance | 50 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
Environmental resistance : Vibration resistance | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each |
Environmental resistance : Shock resistance | 300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each |
Material | Heat-resistant ABS |
Weight | Net weight: 440 g approx. |
Accessory | Insulation plate: 2 pcs. |