Spec Detail
Item | Specifications |
---|---|
Part Number | GD-20-C10 |
Product Number | GD-20-C10 |
Products Name | Metal-sheet Double-feed Detector |
Product details | Sensor head (Long sensing range) |
The price of the product | please contact our office |
Type | Long sensing range |
Applicable controller | GD-C1, GD-C2 |
Sensing range (between sensor heads) | 70 mm 2.756 in or less |
Detectable sheet thickness : Applicable controllers GD-C1/C2 : Setting distance 35 mm 1.378 in | Standard sensing object size: 200 x 200 mm 7.874 x 7.874 in, Iron(SPCC): 0.07 to 10 mm 0.003 to 0.394 in, Aluminum: 0.03 to 10 mm 0.001 to 0.394 in, Copper: 0.03 to 10 mm 0.001 to 0.394 in, Brass: 0.03 to 10 mm 0.001 to 0.394 in, Stainless steel (SUS304): 0.1 to 10 mm 0.004 to 0.394 in (Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above. Please contact our office for details. |
Detectable sheet thickness : Applicable controllers GD-C3 : Setting distance 35 mm 1.378 in | Standard sensing object size: 200 x 200 mm 7.874 x 7.874 in, Iron(SPCC): -, Aluminum: -, Copper: -, Brass: -, Stainless steel (SUS304): - (Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above. Please contact our office for details. |
Detectable sheet thickness : Applicable controllers GD-C1/C2 : Setting distance 70 mm 2.756 in | Standard sensing object size: 200 x 200 mm 7.874 x 7.874 in, Iron(SPCC): 0.07 to 6 mm 0.003 to 0.236 in, Aluminum: 0.03 to 6 mm 0.001 to 0.236 in, Copper: 0.03 to 6 mm 0.001 to 0.236 in, Brass: 0.03 to 6 mm 0.001 to 0.236 in, Stainless steel (SUS304): 0.1 to 6 mm 0.004 to 0.236 in (Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above. Please contact our office for details. |
Detectable sheet thickness : Applicable controllers GD-C3 : Setting distance 70 mm 2.756 in | Standard sensing object size: 200 x 200 mm 7.874 x 7.874 in, Iron(SPCC): -, Aluminum: -, Copper: -, Brass: -, Stainless steel (SUS304): - (Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above. Please contact our office for details. |
Environmental resistance : Protection | IP67 (IEC), IP67G |
Environmental resistance : Ambient temperature | -10 to +60 degrees +14 to +140 degrees Fahrenheit , Storage: -25 to +70 degrees -13 to +158 degrees Fahrenheit |
Environmental resistance : Ambient humidity | 45 to 85 % RH, Storage: 35 to 95 % RH |
Environmental resistance : Vibration resistance | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each |
Environmental resistance : Shock resistance | 1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each |
Material | Sensing face: Polyacetal Main body: Stainless steel |
Cable | Sender: 0.5 2 single core shielded cable, 10 m 32.808 ft long Receiver: 0.3 2 2-core shielded cable, 10 m 32.808 ft long |
Cable extension | Extension up to total 20 m 65.617 ft is possible with an equivalent shielded cable. |
Accessory | - |