Panasonic Industry / Automation Controls
Panasonic Industry / Automation Controls

Control Unit ELC500

  • Basic Information

  • System Configuration

  • Order guide

  • Specifications

  • Dimensions

  • Software

Discontinuation plan

Last time buy

September 30, 2024

Please note that due to various reasons, the order end date may be brought forward.

------------------------------ Tab1 showing ------------------------------

Basic Information

IoT-Ready, Energy-Saving Controller
Contributes to the optimization of energy use by enabling monitoring / control of power demand and visualization of production information

UL/C-UL,CE,UKCA Approved

------------------------------ Tab2 showing ------------------------------

System Configuration

Example of system configuration – For power peak-cut and operation monitoring

(1)  Measurement of power demand

(2)  Demand monitoring at intervals of several seconds

(3)  Collection and storage of production / power information

(4)  Acquisition of production information from PLC and energy information collected by ELC500 Control Unit through Ethernet

(5)  Sharing of demand information via Ethernet and providing demand control

(6)  Collection of information from ELC500 Control Unit via Ethernet

(7)  Demand monitoring(Note) at intervals of several seconds using Web server

(8)  Compilation, analysis and sharing of information by linking with EnerVisualizeR

Note:

Screen must be created using Control Web Creator.

pic01_exp

Enlarged image

------------------------------ Tab3 showing ------------------------------

Order guide

Discontinued products [Order accepted till September, 2024]

Discontinued productRecommended substitute
Product number/Part numberLast time buy Product number/Part numberProduct nameRemark
Product number: UELC500
Part number: UELC500
September 30, 2024
To be discontinued

Product number:-
Part number:-
- Sorry, no suggested alternative products.

[Note]
The following applicable products and options are available continuously.

Software

Product nameModel No.Descriptions
Configurator EL500
(Note)
-Main unit setting software
Control FPWIN Pro7AFPSPR7AProgramming tool
Configurator WD
(Note)
-IP address search tool
Control Web Creator
(Note)
AFPSWCCustom website creation software (Key unit must be purchased.)
Key unitAFPSWCKEYLicense key for Control Web Creator, 1 license, USB port connection

(Note) : Can be downloaded free from the Panasonic website.

Others

Product nameModel No.Descriptions
Backup battery
(supplied)
AFPX-BATTBattery for back up of clock / calendar operation
Power cable
(supplied)
AFPG805Maintenance part. 1 m 3.28 ft length
End unit
(supplied)
AFP7ENDFor connecting the end

------------------------------ Tab4 showing ------------------------------

Specifications

Main unit specifications

ItemSpecification
Rated operating voltage24 V DC
Current consumption300 mA or less (Note)
Ambient temperature0 to +55 ℃ +32 to +131 ℉
Ambient humidity10 to 95% RH(at +25 ℃ +77 ℉, no dew condensation allowed)
Serial communicationEthernet: 1 port, RS-232C: 1 port, RS-485 / 422: 2 ports
Compatible regulationsLow Voltage Directive, EMC Directive, RoHS Directive

Note :

Regarding system consumption current, see the User’s Manual for ELC500 Control Unit.

External memory specifications

ItemSpecification
Supported mediaSD memory card
Compatible formatCompatible with SD / SDHC standards (FAT16 and FAT32 only)
Capacity2 to 32 GB
Speed classClass 2 to Class 10

Notes :

1)  If a (momentary) power outage occurs during writing, data can become corrupted. Use of UPS (Uninterruptible Power Supply) is recommended.

2)  Please use the SLC type SD memory card.
For the handling of SD memory card, see the User’s Manual for ELC500 Control Unit.

Main specifications

ItemSpecification
Communication
(Downstream communication)
• Ethernet: 1 port [supported protocols: MEWTOCOL-COM, Modbus TCP; number of nodes: 197 units; number of simultaneous connections: 20]
• RS-232C: 1 port [supported protocols: MEWTOCOL-COM, Modbus RTU, general-purpose communication]
• RS-485 / 422: 2 ports [supported protocols: MEWTOCOL-COM, Modbus RTU, PLC link, general-purpose communication]
Data collection
(logging) function
• Stored data: Instantaneous values, differential values
• Data storage location, storage format: SD / SDHC memory card, CSV file format
• Maximum number of registerable points: 512 points/16 files (Up to 16 files can be registered. Up to 128 points can be registered in 1 file.)
• Number of storable files: 100 files
Demand monitoring function• Demand type: Constant-cycle (15 / 30 / 60 min) demand; demand cycle: 5 sec (high speed)/min, IEC demand (Note 1) (demand / interval time span: 1 to 60 min)
• Total number of demand monitoring target units: 50 units
• Number of registerable I/O control devices / control patterns: 16 points / alarm-linked control, startup control, cyclic control (ON/OFF control for all) (Note 2)
Network function• Communication protocols: TCP/IP, UDP/IP
• Application protocols: SMTP (SMTP AUTH supported), FTP (client / server), SNTP, DHCP, DNS, HTTP (server)
Email transmission function• Number of registerable points: 16 points
• Subject title: 64 half-width characters (32 full-width characters), Message: 256 half-width characters (128 full-width characters)
Others• Web server function: Custom Web region, 8 MB (Control Web Creator is required), number of simultaneous sessions: 16
• Extension function: Addition of FP7 (PLC) units enables acquisition of information such as I/O signals, analog data and temperature data. Maximum of 8 units (Note 3)
• Program function: 32-k steps Programming is possible when Control FPWIN Pro7 is used.

Notes :

1)  Demand in compliance with IEC 61557-12, “Performance measuring and monitoring devices (PMD)”

2)  Use ECOnect® series remote I/O units (UENU2D4R12).

3)  The number of connectable units is limited. For details, refer to the ELC500 Control Unit Specifications or manual.

Note :

Ethernet is a registered trademark of Fuji Xerox Co., Ltd. and Xerox Corporation in the U.S.
Modbus protocol is a communication protocol developed by Modicon Inc. for use with programmable logic controllers (PLCs).

Others

------------------------------ Tab5 showing ------------------------------

Dimensions

  • Unit: mm in

Tolerance: ±1.0

ELC500

<Shown with card cover and end unit removed>

ELC500

------------------------------ Tab6 showing ------------------------------

Software

Configrator EL500

Software for entering settings for data collection / storage, demand monitoring / control, email, etc. in ELC500 Control Unit

*

SD / SDHC memory card must be purchased separately.

Easy setting

■Setting flow

For collection of data necessary for visualization

Setting flow

■Connection of ELC500 to PC

Connection of ELC500 to PC

■Examples of typical screens

Registration of data storage devices
Used to register devices that collect data. Maximum of 512 points can be registered.

Registration of data storage devices

Demand monitoring / control setting
Used to set demand type and file and enter alarm output control setting.

Demand monitoring / control setting

Current value monitor
Monitors the storage device and main unit status. This screen is useful for checking equipment operations in startup.

Current value monitor

■Items necessary for demand control setting

  • Demand type setting
  • Target demand setting
  • Demand monitoring device setting
  • Remote I/O unit control setting

Control Web Creator

This is a graphics creation tool that allows you to easily design Web content that is published by the ELC500 Control unit. You can creatively design content by arranging Web components such as switches, lamps and meters on the screen and then setting the properties. You can link your content to information in the ELC500 without any knowledge of HTML.

Control Web Creator

  • Same style of operation as the program display image creation tool.
  • Components can be arranged by dragging and dropping.
  • Detailed component settings are easy using properties.
  • Components can be resized without reduction in quality.
  • Images can be pasted in.

Software Download

Software are available for download.
*Control Web Creator : Key unit must be purchased.

>>Go to Data download.

MENU

Recently checked products

Recently checked product numbers