Input side | Control voltage | Input voltage necessary for normal SSR operation under the specified temperature conditions. |
---|
Activation voltage | Threshold at which the output turns on as the control voltage is gradually increased with the specified voltage applied to the loaded output. |
---|
Recovery voltage | Threshold at which the output turns off as the control voltage is gradually decreased with the specified voltage applied to the loaded output. |
---|
Input impedance | Resistance of the current limiting resistor used in the SSR input side. |
---|
Input current | Input current at which an input module SSR operates normally. |
---|
Load side | Max. load current | Maximum continuous current allowable across the SSR output terminals under the specified heat dissipation and ambient temperature conditions. AC current is specified in RMS units. |
---|
Load voltage | Output supply voltage range in which the SSR operates normally. AC voltage is specified in RMS units. |
---|
Non-repetitive surge current | Maximum non-repetitive load current allowable under the specified heat dissipation and ambient temperature conditions. In general, it is given by the peak value of a single cycle of sinusoidal commercial AC current. |
---|
“OFF-state” leakage current | Current that flows in the SSR output circuit when the specified supply voltage is applied to the output with no control voltage applied to the input. |
---|
“ON-state” voltage drop | Output voltage drop caused by a specified load current supplied to the SSR output which is turned on by a specified input control voltage. AC voltage is specified in RMS units. |
---|
On resistance | Resistance value (Ron) between the output terminals when the designated continuous load current (IL) is electrified through the output terminals. Obtained using the equation below from continuous load current (IL) and dropout voltage VDS (on) between the output terminals Ron = VDS (on)/IL |
---|
Min. load current | Minimum load current at and above which the SSR operates normally under the specified temperature conditions. AC load current is specified in RMS units. |
---|
Repetitive peak voltage, max. | Maximum repetitive voltage which can be continuously applied across the SSR output terminals. In general, a voltage of more than 400 V AC is used for 100 V AC applications, and more than 600 V AC for 200-250 V AC applications, to absorb supply voltage variations or on/off surges. |
---|
Critical turn-off voltage rise ratio | SSRs may turn on if a turn-off voltage with a steep rising edge is applied. This phenomenon is called “dv/dt turn on.” Critical turn-off voltage rise ratio refers to the maximum turn-off voltage rise ratio at and below which the SSR remains turned off. |
---|
Max. power dissipation | Allowable power dissipation between the output terminals. |
---|
Electrical Characteristics | Operate time, max. | Time until the SSR output turns on after the specified control voltage is applied to the input. |
---|
Release time, max. | Time until the SSR output turns off after the specified control voltage is removed from the input. |
---|
Insulation resistance | Resistance measured with a specified voltage applied across the input and output, or across the input or output and frame ground. |
---|
Breakdown voltage | Maximum voltage below which no dielectric breakdown occurs when applied for 1 minute across the same test points as those used for insulation resistance testing. |
---|
Vibration resistance | Functional: The device sustains no damage and meets the specifications if it is exposed to vibration with its magnitude not exceeding this threshold during transit or installation. Destructive: Closed contacts of a relay remain closed for the specified time period if it is exposed to vibration with its magnitude not exceeding this threshold during operation. |
---|
Shock resistance | Functional: The device sustains no damage and meets the specifications if it is exposed to physical impact with its magnitude not exceeding this threshold during transit or installation. Destructive: Closed contacts of a relay remain closed for the specified time period if it is exposed to physical impact with its magnitude not exceeding this threshold during operation. |
---|
Ambient temperature | Ambient temperature range over which the SSR operates normally under the specified heat dissipation and load current conditions. |
---|
Storage temperature | Ambient temperature range over which an SSR can be safely stored for extended periods without sustaining damage or performance degradation. |
---|
Maximum switching frequency | Maximum switching frequency at which a SSR can operate normally when applying the specified pulse input to the input terminal |
---|