| Product Number | AHER1282 |
|---|---|
| Part Number | AHER1282 |
| Product Name | HE-R Relays |
| Features | Compact size 2 Form A and 2 Form A 1Form B 80 A/4 Form A and 4 Form A and 1 Form B 40 A power relays |
The external content (including but not limited to ECAD data) displayed hereafter is provided solely as reference data for design evaluation and review purposes. We make no warranties whatsoever with respect to such content, including, without limitation, its accuracy, completeness, usefulness, reliability, fitness for a particular purpose, non-infringement of intellectual property rights or other rights of any third party, or any other matter. In particular, please note that the content displayed hereafter may be presented after being simplified or converted by a third party based on data originally provided by us.
To the maximum extent permitted by applicable law, any use, editing, or any design, evaluation, manufacture, or other activities based on such content shall be undertaken solely at your own risk and responsibility. We shall not be liable for any damages, losses, or expenses arising from or in connection with any of the foregoing, whether in contract, tort (including negligence), strict liability, or otherwise.
Content provided by third parties may be subject to terms and conditions established by such third parties.
If you have read and agree to the above, please click "OK".
Spec Detail
| Item | Specifications |
|---|---|
| Part Number | AHER1282 |
| Product Number | AHER1282 |
| Protective construction | Flux-resistant |
| Operating function | Single side stable |
| Terminal shape | PC board terminal |
| Packing style | Carton |
| Standard packing Carton (pieces) | 10 |
| Standard packing Case (pieces) | 50 |
Coil data
| Item | Specifications |
|---|---|
| Rated coil voltage | 24 V DC |
| Operate voltage (at20℃) | Max. 75% V of rated coil voltage (Initial) |
| Release voltage (at20℃) | Min. 5% V of rated coil voltage (Initial) |
| Rated operating current [±10%] (at 20℃) | 167 mA |
| Coil resistance [±10%] (at 20℃) | 144.0 Ω |
| Rated operating power | 4,000 mW Holding: 490 mW |
| Max. allowable voltage | (at 55℃) 110% V of rated coil voltage |
Specifications
| Item | Specifications |
|---|---|
| Contact arrangement | 2 Form A |
| Contact resistance (initial) | Max. 10 mΩ (by voltage drop 6 V DC 20 A after 3 min.) Max. 3 mΩ (by voltage drop 6 V DC 80 A, reference value) |
| Contact material | AgNi type |
| Contact rating (resistive load) | 80 A 277 V AC |
| Max. switching power (resistive load) | 22,160 VA |
| Max. switching voltage | 277 V AC |
| Max. switching current | 80 A |
| Min. switching load (reference value) | 100 mA 24 V DC |
| Insulation resistance (initial) | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength) |
| Dielectric strength : Between Form A contact and Form B contact | 5,000 Vrms for 1min (detection current: 10 mA) |
| Surge withstand voltage (initial) : Between contact and coil | 10,000 V (Between Form A contact and coil) |
| Coil holding voltage | 35 to 110% V (at -40 to +55℃, Form A contact: 80 A) 35 to 50% V (at -40 to +85℃, Form A contact: 70 A to 80 A) |
| Operate time (initial) (at 20℃) | Max. 50 ms at rated coil voltage (without bounce) |
| Release time (initial) (at 20℃) | Max. 30 ms at rated coil voltage (without bounce, without diode) |
| Shock resistance (Functional) (initial) | 25 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs) |
| Shock resistance (Destructive) (initial) | 980 m/s2 (half-sine shock pulse: 6 ms) |
| Vibration resistance (Functional)(initial) | 10 to 55 Hz (at double amplitude of 0.3 mm, detection time: 10 μs) |
| Vibration resistance (Destructive)(initial) | 10 to 55 Hz (at double amplitude of 1.5 mm) |
| Mechanical life | Min. 100x103 ope. (switching frequency: at 180 times/min) |
| Conditions | Ambient temperature: -40 to +55℃ (When applied coil hold voltage is 35 to 110 % V of rated coil voltage.) Ambient temperature: -40 to +85℃ (When applied coil hold voltage is 35 to 50 % V of rated coil voltage or storage.) Humidity: 5 to 85% RH (Avoid icing and condensation) |
| Unit weight | Approx. 180g |
Expected electrical life
| Item | Specifications |
|---|---|
| Resistive load | [switching frequency ON : OFF = 1 s : 9 s] Min. 50x103 ope. 63 A 277 V AC Min. 30x103 ope. 70 A 277 V AC Min. 10x103 ope. 80 A 277 V AC |
Information on Compliance with Standards
| Status | Status | Information on Compliance | ||
|---|---|---|---|---|
| UL/C-UL | Approval 認定書(写)を 請求する | File No. | E43149 | |
| Rating | a contact 63A make/break 80A carry 277V AC Resistive 50000 cycles 85°C 70A 277V AC Resistive 30000 cycles 85°C 80A 277V AC Resistive 10000 cycles 85°C | |||
| Remarks | - | |||
| Last update | ||||
| CSA | N/A | File No. | - | |
| Rating | - | |||
| Remarks | CSA standard certified by C-UL | |||
| Last update | ||||
| VDE | Approval 認定書(写)を 請求する | File No. | 40053274 | |
| Rating | a contact 63A make/break 80A carry 250V AC (cosφ=1) 50000 cycles 85°C 70A 250V AC (cosφ=1) 30000 cycles 85°C 80A 250V AC (cosφ=1) 10000 cycles 85°C | |||
| Remarks | - | |||
| Last update | ||||
| Mark on products* | ||||
* The "Mark on products" field shows the standards' certificate type marked to products. Note that not all certified products have a certificate mark affixed to them.