ADW1209HLW|DW Relays
Download

*Photo may vary from actual product.
This product has been confirmed that it does not contain the 6 substances specified in EU RoHS Directive 2011/65/EU and the 4 substances specified in 2015/863/EU.
Product Number | ADW1209HLW |
---|---|
Part Number | ADW1209HLW |
Details | Inrush type (16 A), Inrush current 100 A, Low profile type |
Product Name | DW Relays |
Features | 1 Form A 8 A/16 A, Small, Polarized power relays (latching type) |
*Specifications and design of the products are subject to change without notice for the product improvement.
Spec Detail
Specifications and design of the products are subject to change without notice for the product improvement.
Item | Specifications |
---|---|
Part Number | ADW1209HLW |
Product Number | ADW1209HLW |
Product details | Inrush type (16 A), Inrush current 100 A, Low profile type |
Protective construction | Flux-resistant |
Operating function | 2 coil latching |
Terminal shape | PC board terminal |
Contact rating type | Inrush type (16A, Inrush current 100A) |
Type classification | Low profile type |
Packing style | Carton |
Standard packing Carton (pieces) | 100 |
Standard packing Case (pieces) | 500 |
Coil data
Item | Specifications |
---|---|
Rated coil voltage | 9 V DC |
Set voltage (at20℃) | Max. 80% V of rated coil voltage (Initial) |
Reset voltage (at20℃) | Max. 80% V of rated coil voltage (Initial) |
Rated operating current [±10%] (at 20℃) | Set coil: 44.4 mA Reset coil: 44.4 mA |
Coil resistance [±10%] (at 20℃) | Set coil: 202.5 Ω Reset coil: 202.5 Ω |
Rated operating power | 400 mW |
Max. allowable voltage (at 20℃) | 110% V of rated coil voltage |
Specifications
Item | Specifications |
---|---|
Contact arrangement | 1 Form A |
Contact shape | Single |
Contact resistance (initial) | Max. 100 mΩ (by voltage drop 6 V DC 1 A) |
Contact material | AgSnO2 type |
Contact rating (resistive load) | 16 A 277 V AC |
Max. switching power (resistive load) | 4,432 VA |
Max. switching voltage | 277 V AC |
Max. switching current | 16 A (AC) |
Min. switching load (reference value) | 100 mA 5 V DC |
Insulation resistance (initial) | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) |
Dielectric strength (initial) : Between open contacts | 1,000 Vrms for 1 min (detection current: 10 mA) |
Dielectric strength (initial) : Between contact and coil | 5,000 Vrms for 1 min (detection current: 10 mA) |
Surge withstand voltage (initial) : Between contact and coil | 12,000 V |
Set time (Initial) (at 20℃) | Max. 15 ms at rated coil voltage (without bounce) |
Reset time (Initial) (at20℃) | Max. 15 ms at rated coil voltage (without bounce) |
Shock resistance (Functional) | 100 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs) |
Shock resistance (Destructive) | 1,000 m/s2 (half-sine shock pulse: 6 ms) |
Vibration resistance (Functional) | 10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 μs) |
Vibration resistance (Destructive) | 10 to 55 Hz (at double amplitude of 3 mm) |
Mechanical life | Min. 106 ope. (switching frequency: at 180 times/min) |
Conditions | Ambient temperature: -40 to +70℃ (Over 8A to 16A) Ambient temperature: -40 to +85℃ (8A or less) Humidity: 5 to 85% RH (Avoid icing and condensation) |
Unit weight | Approx. 7.5 g |
Expected electrical life
Item | Specifications |
---|---|
Resistive load | Min. 50x103 ope. 8 A 250 V AC (switching frequency: 20 times/min) Min. 20x103 ope. 16 A 277 V AC (switching frequency ON : OFF = 1 s : 5 s) |
Electrical life
Item | Specifications |
---|---|
Inrush load; Tungsten | Min. 25x103 ope. Inrush current: 100 A 600 W 120 V AC (switching frequency ON : OFF = 1 s : 59 s) |
Information on Compliance with Standards
Specifications and design of the products are subject to change without notice for the product improvement.
Status | Status | Information on Compliance | ||
---|---|---|---|---|
UL/C-UL | Approval 認定書(写)を 請求する | File No. | E43149 | |
Rating | 16A 277V AC R 50,000cycles at60°C 16A 277V AC R 20,000cycles at85°C 8A 250V AC R 50,000cycles at85°C 5A 347V AC R 50,000cycles at85°C(UL only) 5A 30V DC R 50,000cycles at85°C 1200W Tungsten 240V AC 6,000cycles at50°C 600W Tungsten 120V AC 25,000cycles at50°C 1A 277V AC Electronic ballast 12,000cycles at40°C 2A 277V AC Electronic ballast 6,000cycles at40°C 5A 120V AC Electtonic ballast 6,000cycles at70°C(2coil latching type only) 5A 277V AC Standard ballast 6,000cycles at50°C | |||
Remarks | - | |||
Last update | ||||
CSA | N/A | File No. | - | |
Rating | - | |||
Remarks | CSA standard certified by C-UL | |||
Last update | ||||
VDE | Approval 認定書(写)を 請求する | File No. | 40032254 | |
Rating | 16A 277V AC (cosφ=1.0) 50,000cycles at70°C 16A 277V AC (cosφ=1.0) 20,000cycles at85°C 8A 250V AC (cosφ=1.0) 50,000cycles at85°C 5A 30V DC (0ms) 50,000cycles at85°C *1) 24A 277V AC (cosφ=1.0) 50cycles at85°C *2) 16A 277V AC (cosφ=1.0) 10,000cycles at 85°C | |||
Remarks | *1) Test according to DIN EN 62368-1 (VDE 0868-1) / IEC62368-1 ; Clause G.2.2 *2) Test according to DIN EN 62368-1 (VDE 0868-1) / IEC62368-1 ; Clause G.2.1 : No temporary malfunction allowe | |||
Last update | ||||
TV | Approval 認定書(写)を 請求する | File No. | E43149 | |
Rating | TV-8 (240V AC) 25,000cycles at40°C | |||
Remarks | - | |||
Last update | ||||
CQC | Approval 認定書(写)を 請求する | File No. | CQC16002150890 | |
Rating | 16A 250V AC | |||
Remarks | - | |||
Last update | ||||
Mark on products* |
* The "Mark on products" field shows the standards' certificate type marked to products. Note that not all certified products have a certificate mark affixed to them.