ER-X001|Pulse AC Method Area Ionizer ER-X
Download

*Photo may vary from actual product.
This product has been confirmed that it does not contain the 6 substances specified in EU RoHS Directive 2011/65/EU and the 4 substances specified in 2015/863/EU.
Product Number | ER-X001 |
---|---|
Part Number | ER-X001 |
Product | Pulse AC Method Area Ionizer |
Details | Head |
Product Name | Pulse AC Method Area Ionizer ER-X |
Contact Us
*Specifications and design of the products are subject to change without notice for the product improvement.
Spec Detail
Specifications and design of the products are subject to change without notice for the product improvement.
Item | Specifications |
---|---|
Part Number | ER-X001 |
Product Number | ER-X001 |
Products Name | Pulse AC Method Area Ionizer |
Product details | Head |
The price of the product | Please contact our office |
Applicable regulations and certifications | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), TÜV SÜD certification (USA, Canada) |
Effective charge removal width | 50 mm 1.969 in approx. |
Charge removal time | 0.3 sec. or less (Note 1), 0.5 sec. or less (Note 2) (Note 1: Typical value in condition of discharge distance 50 mm 1.969 in, center of the product, discharge wavelength 50 Hz and air supply 60 ℓ / min. (0.3 MPa)) . (Note 2: Typical value in condition of discharge distance 50 mm 1.969 in, center of the product, discharge wavelength 50 Hz and no air supply.) |
Ion balance | ±30 V or less (Note 1:Typical value in condition of discharge distance 100 mm 3.937 in, center of the product, discharge frequency 30 Hz and no air supply.) (Note 2: Ion balance refers to the average value of plus and minus. The specification value is the typical one in condition used when ambient temperature change is less than ±10 ℃, ion balance is set after 30 minutes from the discharge start, the ion balance control function is set ON.) |
Discharge method | Pulse AC method (Note:The discharge frequencies of 50 Hz, 20 Hz are accepted.) |
Discharge frequency | 50 Hz / 20 Hz |
Discharge output voltage | ±7,000 V approx. |
Ozone generation | 0.01 ppm or less (Note:Typical value in condition of discharge distance 50 mm 1.969 in, center of the product, discharge wavelength 50 Hz and no air supply.) |
Maximum air pressure | 0.5 MPa |
Applicable fluid | Air (dried clean air) (Note:The dried clean air is the air dried (dew point: equivalent of -20 ℃ -4 ℉) and filtered (mesh-size: equivalent of 0.01 μm) .) |
Operating altitude | 2,000 m 6561.68 ft or less (Note:Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.) |
Ambient temperature | 0 to +40 ℃ +32 to +104 ℉ (No dew condensation), Storage: -10 to +65℃ +14 to +149℉ |
Ambient humidity | 35 to 65 % RH, Storage: 35 to 85 % RH |
Vibration resistance | 10 to 55 Hz frequency, 0.75 mm 0.030 in (Max. acceleration 50 m/s2) double amplitude in X, Y and Z directions for two hours each |
Shock resistance | 100 m/s2 acceleration (10 G approx.), in X, Y and Z directions three times each |
Enclosure earthing | Floating |
Material | Main unit enclosure: Stainless steal (SUS) Head mounting bracket: Stainless steal (SUS) Discharge needle: PFA, Tungsten |
Length of high-voltage cable | 1.2 m 3.937 ft |
Weight | Net weight : 370 g approx. |
Accessories | Head mounting bracket (installed at the time of factory shipment) |