Product Number | EC-G02 |
---|---|
Part Number | EC-G02 |
Product | Pulse Air-gun Ionizer |
Details | Gun type |
Product Name | Pulse Air-gun Ionizer EC-G |
Contact Us
*Specifications and design of the products are subject to change without notice for the product improvement.
Spec Detail
Specifications and design of the products are subject to change without notice for the product improvement.
Item | Specifications |
---|---|
Part Number | EC-G02 |
Product Number | EC-G02 |
Products Name | Pulse Air-gun Ionizer |
Product details | Gun type |
Applicable regulations | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) |
Charge removal time | 0.5 sec. or less approx. (±1,000 V → ±100 V) Note : Typical value for continuous pulse air mode at 100 mm 3.937 in from the end of discharge nozzle at an applied air pressure of 0.50 MPa. |
Ion balance | ±10 V or less Note : Typical value for continuous pulse air mode at 100 mm 3.937 in from the end of discharge nozzle at an applied air pressure of 0.50 MPa. |
Applicable fluid | Air (dried clean air) (Note):Dried clean air is the air passing through air dryer (dew point -20 ℃ -4 ℉ approx.) and air filter (mesh size 0.01 μm 0.0004 mil approx.) |
Supplied air flow | 300 ℓ/min. (ANR) or less |
Air pressure range | 0.05 to 0.50 MPa |
Supply voltage | Accessory AC adapter • INPUT: 100-240 V AC ±10 % 50/60 Hz • OUTPUT: 24 V DC Operating voltage of ionizer body: 24V DC |
Power consumption | 30 VA or less |
Discharge method | High-frequency AC method |
Discharge output voltage | Approx. 2,000 V |
Ozone generation | 0.02 ppm or less Note : Typical value for continuous pulse air mode at 300 mm 11.881 in from the end of discharge nozzle at an applied air pressure of 0.25 MPa. |
Pulse air mode | Pulse 1 (long) / Pulse 2 (short) / CONT (continuous) selectable by switch |
LED illumination mode | ON (always ON) / SYNC (synchronized with trigger) / OFF (always OFF) |
External input | Ionized air emission operation ON / OFF using OR control with trigger switch Ionized air emission operation ON: Short-circuited to COM (-) Ionized air emission operation OFF: Open |
Operating altitude | 2,000 m or less Note : Do not use or store the device in an environment where the air pressure is higher than the atmospheric pressure at an altitude of 0 m. |
Ambient temperature | 0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), AC adapter: 0 to +40 ℃ +32 to +104 ℉ |
Ambient humidity | 35 to 65 % RH (No dew condensation allowed) |
Material | Enclosure: ABS, Nozzle: Stainless steel, Discharge needle: Tungsten, Nozzle guard: NBR |
Weight | 270 g approx. (main unit only) |
Accessories | AC adapter (manufactured by ENG ELECTRIC, model: 6A-181-WP24): 1 pc. Exclusive intermediate cable (oil-resistant, heat-resistant, bending-resistant type) length 2 m 6.562 ft: 1 pc. Straight joints • Tube outer diameter ø8-ø8 mm ø0.315-ø0.315 in compatible type: 1 pc.(Note: Typical value for continuous pulse air mode at 300 mm 11.881 in from the end of discharge nozzle at an applied air pressure of 0.25 MPa.) • Tube outer diameter ø8-ø6 mm ø0.315-ø0.236 in compatible type: 1 pc. • Connector connection terminal (Manufactured by Molex): 3 pcs. |
Remark | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉. |