SF4C-H20-J05|Ultra-slim Safety Light Curtain Type 4 PLe SIL3 SF4C
Download
*Photo may vary from actual product.
This product has been confirmed that it does not contain the 6 substances specified in EU RoHS Directive 2011/65/EU and the 4 substances specified in 2015/863/EU.
Product Number | SF4C-H20-J05 |
---|---|
Part Number | SF4C-H20-J05 |
Product | Ultra-slim Safety Light Curtain [Type 4 PLe SIL3] |
Details | Min. sensing object ø25 mm ø0.984 in type (20 mm 0.787 in beam pitch) [Pigtailed type] |
Product Name | Ultra-slim Safety Light Curtain Type 4 PLe SIL3 SF4C |
*Specifications and design of the products are subject to change without notice for the product improvement.
Spec Detail
Specifications and design of the products are subject to change without notice for the product improvement.
Item | Specifications |
---|---|
Part Number | SF4C-H20-J05 |
Product Number | SF4C-H20-J05 |
Products Name | Ultra-slim Safety Light Curtain [Type 4 PLe SIL3] |
Product details | Min. sensing object ø25 mm ø0.984 in type (20 mm 0.787 in beam pitch) [Pigtailed type] |
The price of the product | Please contact our office |
No. of beam channels | 20 |
Protective height | 400 mm 15.748 in |
Current consumption:Large multipurpose indicator lights off | Emitter: 75 mA or less Receiver: 95 mA or less |
Current consumption:Large multipurpose indicator lights up | Emitter: 120 mA or less Receiver: 145 mA or less |
PFHD | 1.53 × 10-9 |
MTTFD | 100 years or more |
Net weight (Total of emitter and receiver) | 420 g approx. |
Applicable standards:International standard | IEC 61496-1/2 (Type 4), ISO 13849-1:2015 (Category 4, PLe), IEC 61508-1 to 3 (SIL 3) |
Applicable standards:Japan | JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 3(SIL3) |
Applicable standards:Europe | EN 61496-1 (Type 4), EN ISO 13849-1:2015 (Category 4, PLe), EN 61508-1 to 3 (SIL 3), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate. |
Applicable standards:North America | ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14,OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 (Note) With regards to the standards in the US/Canada, a Notified Body, TÜV SÜD, has certified the CTÜVUS mark. |
Applicable regulations and certifications | CE Marking (Machinery Directive, EMC Directive, RoHS Directive), UKCA Marking [Supply of Machinery (Safety) Regulations, EMC Regulations, RoHS Regulations], TÜV SÜD certification |
Operating range | 0.1 to 3 m 0.328 to 9.843 ft (Note) The operating range is the possible setting distance between the emitter and the receiver. |
Beam pitch | 20 mm 0.787 in |
Min. sensing object | ø25 mm ø0.984 in opaque object (Note) When the floating blanking function is used, the size of the min. sensing object is changed. |
Effective aperture angle | plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)] |
Power voltage | 24 V DC +10-15 % Ripple P-P 10 % or less |
Control outputs (OSSD 1, OSSD 2) | PNP open-collector transistor / NPN open-collector transistor (switching method) [When selecting PNP output] - Max. source current: 200 mA - Applied voltage: same as supply voltage (between the control output and +V) - Residual voltage: 2.5 V or less (source current 200 mA, when using 10 m 32.808 ft length cable) - Leakage current: 200 micro A or less (including power supply OFF condition) - Max. load capacity: 1 micro F (No load to Max. output current) - Load wiring resistance: 3 Ω or less [When selecting NPN output] - Max. sink current: 200 mA - Applied voltage: same as supply voltage (between the control output and 0 V) - Residual voltage: 2.5 V or less (sink current 200 mA, when using 10 m 32.808 ft length cable) - Leakage current: 200 micro A or less (including power supply OFF condition) - Max. load capacity: 1 micro F (No load to Max. output current) - Load wiring resistance: 3 Ω or less |
Control outputs (OSSD 1, OSSD 2):Operation mode | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal) (Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped. (Note) In case the blanking function is valid, the operation mode is changed. |
Control outputs(OSSD1, OSSD2):Protection circuit | Incorporated |
Response time | OFF response: 7 ms or less ON response: 90 ms or less |
Auxiliary output (Non-safety output) | PNP open-collector transistor / NPN open-collector transistor (switching method) [When selecting PNP output] - Max. source current: 100 mA - Applied voltage: same as supply voltage (between the auxiliary output and +V) - Residual voltage: 2.5 V or less (source current 100 mA, when using 10 m 32.808 ft length cable) [When selecting NPN output] - Max. sink current: 100 mA - Applied voltage: same as supply voltage (between the auxiliary output and 0 V) - Residual voltage: 2.5 V or less (sink current 100 mA, when using 10 m 32.808 ft length cable) |
Auxiliary output (Non-safety output):Operation mode | OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFC-HC handy-controller). |
Auxiliary output (Non-safety output):Protection circuit | Incorporated |
ELCA function | Incorporated (reducing mutual interference automatically) |
Test / reset input function | Incorporated |
Interlock function | Incorporated [Manual reset / Automatic reset (Note)] (Note) The manual reset and automatic reset are possible to be switched depending on the wiring status. |
External device monitoring function | Incorporated |
Safety input function | Incorporated (safety contact) |
Muting function | Incorporated |
Override function | Incorporated |
Optional functions | Fixed blanking, floating blanking, auxiliary output change, safety input (safety sensor), large multi-purpose indicator setting change, interlock setting change, external relay monitoring setting change, muting setting change, override setting change, protecting (Note) In case of using optional function, the handy-controller SFC-HC is required. |
Pollution degree | 3 |
Operating altitude | 2,000 m 6,561 68 ft or less (Note:Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.) |
Environmental resistance:Degree of protection | IP67 / IP65 (IEC) |
Environmental resistance:Ambient temperature | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +60 ℃ -13 to +140 ℉ |
Environmental resistance:Ambient humidity | 30 to 85 % RH, Storage: 30 to 85 % RH |
Ambient illuminance | Incandescent light: 5,000 lx or less at the light-receiving face |
Environmental resistance:Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
Environmental resistance:Insulation resistance | 20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure |
Environmental resistance:Vibration resistance | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each |
Environmental resistance:Shock resistance | 300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each |
Emitting element | Infrared LED (Peak emission wavelength: 855 nm 0.034 mil) |
Material | Enclosure: Polycarbonate alloy Sensing surface: Polycarbonate alloy |
Cable | 0.15mm2 (power line: 0.2 mm2) 12-core heat-resistant PVC cable, 0.5 m 1.640 ft long with connector |
Cable extension | Extension up to 40.5 m 132.874 ft is possible for both emitter and receiver, with 0.2 mm2 or more cable. (Note) When the muting lamp is used, the cable can be extended within 30.5 m 100.066 ft (for emitter / receiver). |
Accessories | MS-SFC-1 (Standard mounting bracket): 1 set SF4C-TR25 (Test rod): 1 No. |