EX-F1-C5|Pipe-mountable Liquid Level Detection Sensor EX-F1
Download
*Photo may vary from actual product.
This product has been confirmed that it does not contain the 6 substances specified in EU RoHS Directive 2011/65/EU and the 4 substances specified in 2015/863/EU.
Product Number | EX-F1-C5 |
---|---|
Part Number | EX-F1-C5 |
Product | Pipe-mountable Liquid Level Detection Sensor |
Details | Amplifier built-in, Pipe-mountable, 5 m 16.404 ft cable length type |
Product Name | Pipe-mountable Liquid Level Detection Sensor EX-F1 |
*Specifications and design of the products are subject to change without notice for the product improvement.
Spec Detail
Specifications and design of the products are subject to change without notice for the product improvement.
Item | Specifications |
---|---|
Part Number | EX-F1-C5 |
Product Number | EX-F1-C5 |
Products Name | Pipe-mountable Liquid Level Detection Sensor |
Product details | Amplifier built-in, Pipe-mountable, 5 m 16.404 ft cable length type |
Applicable regulations | EMC Directive, RoHS Directive |
Sensing object | Liquid (Note):Unclear or highly viscous liquid may not be detected stably. |
Applicable pipe diameter | Outer dia. ø6 to ø13 mm ø0.236 to ø0.512 in transparent resin pipe [PFA (Fluorine resin) or equivalently transparent pipe, wall thickness 1 mm 0.039 in ] (Note:Do not use the sensor with pipes other than the above specified.) |
Supply voltage | 12 to 24 V DC ± 10 % Ripple P-P 10 % or less |
Current consumption | 30 mA or less (Note:Unclear or highly viscous liquid may not be detected stably.) |
Output | NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current) |
Output:Output operation | Switchable either Light-ON (Liquid-absent-ON) or Dark-ON (Liquid-present-ON) |
Output:Short-circuit protection | Incorporated |
Response time | 2 ms or less |
Operation indicator | Red LED (lights up when the output is ON) |
Ambient temperature | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉ (Note:Liquid being detected should also be kept within the rated ambient temperature range.) |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Ambient illuminance | lncandescent light: 3,000 lx or less at the light-receiving face |
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
Insulation resistance | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure |
Vibration resistance | 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each |
Shock resistance | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each |
Emitting element | Infrared LED (modulated) |
Material | Enclosure: Polycarbonate, Tying band: Nylon, Anti-slip tube: Silicone |
Accessory | Tying band: 2 pcs., Anti-slip tube: 2 pcs. |