FX-551|Digital Fiber Sensor FX-550
Download
*Photo may vary from actual product.
This product has been confirmed that it does not contain the 6 substances specified in EU RoHS Directive 2011/65/EU and the 4 substances specified in 2015/863/EU.
Product Number | FX-551 |
---|---|
Part Number | FX-551 |
Product | Digital Fiber Sensor |
Details | Amplifiers Connector type |
Product Name | Digital Fiber Sensor FX-550 |
*Specifications and design of the products are subject to change without notice for the product improvement.
Spec Detail
Specifications and design of the products are subject to change without notice for the product improvement.
Item | Specifications |
---|---|
Part Number | FX-551 |
Product Number | FX-551 |
Products Name | Digital Fiber Sensor |
Product details | Amplifiers Connector type |
Applicable regulations | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) |
Supply voltage | 12 to 24 V DC +10-15 % Ripple P-P 10 % or less |
Power consumption | Normal operation : 960 mW or less (current consumption 40 mA or less at 24 V supply voltage) ECO mode : 680 mW or less (current consumption 28 mA or less at 24 V supply voltage) |
Output | <NPN output type> NPN open-collector transistor ・Maximum sink current : 100 mA ・Applied voltage : 30 V DC or less (between output and 0 V) ・Residual voltage : 2 V or less (Note) (at maximum sink current) (Note): In case of using the quick-connection cable (cable length 5 m 16.404 ft)(optional). |
Output:Output operation | Switchable either Light-ON or Dark-ON by L/D mode |
Output:Short-circuit protection | Incorporated |
Response time | FAST : 60μs or less, STD : 250μs or less, LONG : 2ms or less, U-LG : 4ms or less, HYPR : 24ms or less, selectable |
Sensitivity setting | 2-point teaching / Limit teaching / Full-auto teaching / Manual adjustment |
Incident light sensitivity setting | Incorporated, 4 steps |
Incident light intensity display range | FAST / STD : 0 to 4,000, LONG : 0 to 8,000, U-LG / HYPR : 0 to 9,999 |
Timer function | Incorporated with variable OFF-delay / ON-delay / One-shot / switchable either effective or ineffective |
Timer function:Timer period | Timer range "ms" : 1 to 9,999 ms approx., 1 ms approx., Timer range "sec." : 1 to 32 s approx., 1 s approx., Timer range "1/10 ms" : 0.1 to 999.9 ms approx., 0.1 ms approx. (Note): When set to LONG, U-LG, HYPR, IP-F or IP-R, the time range cannot be set to 1/10 ms. |
Different frequency interference prevention function | Incorporated (up to 4 units). Note that the response time varies depending on the setting. F-1 : 0.8 ms or less, F-2 : 0.9 ms or less, F-3 : 1.0 ms or less, F-4 : 1.7 ms or less (Note): This function increases the hysteresis. Check the sensing condition when using the function. |
Protection | IP40(IEC) |
Ambient temperature | -10 to +55 ℃ +14 to +131 ℉ (If 4 to 7 units are mounted in cascade : -10 to +50 ℃ +14 to +122 ℉ or if 8 to 16 units are mounted in cascade : -10 to +45 ℃ +14 to +113 ℉)(No dew condensation or icing allowed), Storage : -20 to +70 ℃ -4 to +158 ℉ |
Vibration resistance | 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (10 G max.) in X, Y and Z directions for two hours each |
Shock resistance | 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each |
Emitting element (modulated) | Red LED (Peak emission wavelength : 660 nm 0.026 mil) |
Material | Enclosure, Case cover : Polycarbonate, Switch : Polyacetal |
Cable | - |
Cable extension | - |
Weight | Net weight : 15 g approx., Gross weight : 55 g approx. |
Remark | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉. |