Product Number | AGM1NSCS1M1 |
---|---|
Part Number | AGM1NSCS1M1 |
Product | Serial Communication Unit |
Product Name | Motion Controller GM1 |
*Specifications and design of the products are subject to change without notice for the product improvement.
Spec Detail
Specifications and design of the products are subject to change without notice for the product improvement.
Item | Specifications |
---|---|
Part Number | AGM1NSCS1M1 |
Product Number | AGM1NSCS1M1 |
Products Name | Serial Communication Unit |
General specifications
Item | Specifications |
---|---|
Rated voltage | 24 V DC |
Operating voltage range | 20.4 to 28.8 V DC |
Allowable momentary power failure time | 10 ms |
Operating ambient temperature | 0 to +55℃ |
Storage ambient temperature | -40~+70 ℃ |
Operating ambient humidity | 10 to 95 % RH (at +25 ℃, no condensation or icing) |
Storage ambient humidity | 10 to 95 % RH (at +25 ℃, no condensation or icing) |
Dielectric strength (Leakage current: 5 mA) | 500 V AC for one minute *Please refer to the unit's specification sheet for details of breakdown voltage and insulation resistance. |
Insulation resistance (Test voltage: 500 V DC) | 100 MΩ or more *Please refer to the unit's specification sheet for details of breakdown voltage and insulation resistance. |
Vibration resistance | Compliant with JIS B 3502, IEC 61131-2 5 to 8.4 Hz, half amplitude 3.5 mm, 8.4 to 150 Hz acceleration 9.8 m/s2 10 sweeps each in X, Y and Z directions (1 octave/min) |
Shock resistance | Compliant with JIS B 3502, IEC 61131-2 147 m/s2, 3 times each in the X, Y, Z directions |
Noise resistance | 1000 V [p-p] with pulse widths of 1 μs and 50 ns (using a noise simulator) (Power supply terminal) |
Atmosphere | Free of corrosive gases No excessive dust |
European EU Standards | EMC: EN 61131-2 RoHS: EN IEC 63000 |
Overvoltage category | Category II |
Pollution degree | 2 |
Weight (main unit) | Approx. 150 g (including the terminal block) |
Consumption current | 130 mA or less |
Communication Specifications
Item | Specifications |
---|---|
Interface | Connector 1: RS-232C Connector 2: RS-422A/485 |
Communication method | RS-232C: Full-duplex / half-duplex RS-422A: Full-duplex / half-duplex RS-485: Half-duplex |
Transmission distance | RS-232C: Max. 15 m RS-422A: Max. 1,200 m(Note 1)(total extension distance) RS-485: Max. 1,200 m(Note 1)(total extension distance) (Note 1) Check the transmission distance using the actual unit as it may depend on the destination device. The recommended transmission distance is 100 m or less. |
Transmission mode : Number of destination units | RS-232C: 1:1 RS-422A: 1:1 RS-485: 1:N (N = 32 max.) |
Protocol | General-purpose communication / Modbus-RTU (master / slave) |
Baud rate | General-purpose communication: 1,200 / 2,400 / 4,800 / 9,600 / 19,200 / 38,400 / 57,600 / 115,200 / 230,400 bps Modbus-RTU: 1,200 / 2,400 / 4,800 / 9,600 / 19,200 / 38,400 / 57,600 / 115,200 bps |
Maximum data length | General-purpose: 1,024 Byte Modbus-RTU: 252 Byte |
Communication format | Data length: 7 bit / 8 bit Parity: None, odd, even Stop code: 1 bit / 2 bit Start code: None End code: None |