Spec Detail
Item | Specifications |
---|---|
Part Number | VF-M10 |
Product Number | VF-M10 |
Products Name | Terminal Connection Type Multi-voltage Photoelectric Sensor |
Product details | Thru-beam |
The price of the product | Please contact our office |
Sensing range | 10 m 32.808 ft |
Sensing object | dia. 20 mm dia. 0.787 in or more opaque object (Note) If slit masks (optional) are fitted, even an object of 3 x 6 mm 0.118 x 0.236 in can be detected. |
Hysteresis | - |
Supply voltage | 24 to 240 V AC +10-15% or 12 to 240 V DC +10-15% |
Power consumption | Emitter: 3 VA or less (Average: 1.5 W or less) Receiver: 3 VA or less (Average: 1.5 W or less) |
Output | Relay contact 1a - Switching capacity: 250 V 1 A AC (resistive load), 30 V 2 A DC (resistive load) - Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour) - Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour) |
Output:Output operation | Switchable either Light-ON or Dark-ON |
Response time | 20 ms or less |
Operation indicator | Red LED (lights up when the output is ON) |
Sensitivity adjuster | - |
Timer function(0.1 to 5 sec. variable) | - |
Pollution degree | 3 (Industrial environment) |
Protection | IP66 (IEC) |
Ambient temperature | -10 to +60 degrees +14 to +140 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -20 to +70 degrees -4 to +158 degrees Fahrenheit |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Ambient illuminance | Incandescent light: 3,500 Lx at the light-receiving face |
EMC | EN 61000-6-2, EN 61000-6-4 |
Voltage withstandability | 1,500 V AC for one min. between the power supply and output terminals 1,000 V AC for one min. between the relay contact terminals |
Insulation resistance | 20 MOhm , or more, with 500 V DC megger between the power supply and output terminals, and between the relay contact terminals |
Vibration resistance | 10 to 55 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each |
Shock resistance | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions for three times each |
Emitting element (modulated) | Infrared LED |
Emitting element (modulated):Peak emission wavelength | 950 nm 0.037 mil |
Material | Enclosure: PBT Lens: Acrylic |
Connection method | Screw-on terminal connection |
Cable | Suitable for round cable dia. 6 to dia. 10 mm dia. 0.236 to dia. 0.394 in (Conductor cross-section area: 0.25 to 0.75 mm2). |
Cable length | Total length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cabtyre cable (both emitter and receiver). |
Weight | Emitter: 75 g approx Receiver: 95 g approx |
Accessory | MS-N70 (Sensor mounting bracket): 2 set Gland and gland washer: 2 set Gland packing (large/small 1 pc. each): 2 set VF-SKG (Short-circuit metal joint): 1 pc |