PX-24|Long Range & Wide Area Photoelectric Sensor PX-2
Download
*Photo may vary from actual product.
This product has been confirmed that it does not contain the 6 substances specified in EU RoHS Directive 2011/65/EU and the 4 substances specified in 2015/863/EU.
Product Number | PX-24 |
---|---|
Part Number | PX-24 |
Product | Long Range & Wide Area Photoelectric Sensor |
Details | Main sensors(Auxiliary sensor connectable model) |
Product Name | Long Range & Wide Area Photoelectric Sensor PX-2 |
*Specifications and design of the products are subject to change without notice for the product improvement.
Spec Detail
Specifications and design of the products are subject to change without notice for the product improvement.
Item | Specifications |
---|---|
Part Number | PX-24 |
Product Number | PX-24 |
Products Name | Long Range & Wide Area Photoelectric Sensor |
Product details | Main sensors(Auxiliary sensor connectable model) |
Applicable regulations | EMC Directive, RoHS Directive |
Sensing range (OUT 1 and OUT 2 areas) | 3 m 9.843 ft (Note:The sensing range is specified for white non-glossy paper (300 x 300 mm 11.811 × 11.811 in) as the object.) |
Hysteresis | 15 % or less of operation distance (Note:The sensing range is specified for white non-glossy paper (300 x 300 mm 11.811 × 11.811 in) as the object.) |
Supply voltage | 10 to 31 V DC including ripple |
Power consumption | Under operation: 1.5 W or less, Under sleep condition: 0.3 W or less (without auxiliary sensor) (Note:Obtain the current consumption by the following calculation. Current consumption = Power consumption ÷ Supply voltage (e.g.) When the supply voltage is 12 V, the current consumption (operating condition) is: 1.5 W ÷ 12 V = 0.125 A = 125 mA) |
OUT1, OUT2 | NPN open-collector transistor ・Maximum sink current: 100 mA ・Applied voltage: 40 V DC or less between OUT 1 / OUT 2 and 0 V) ・Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current) * OUT1(OR circuit among the effective center, left, right, adjacent left / right OUT 1 areas and the effective auxiliary left / right areas) OUT2(OR circuit among the effective center, left and right OUT 2 areas) |
OUT1, OUT2:Output operation | Selectable either Light-ON or Dark-ON with a switch (Output operation of OUT 1 and OUT 2 is the same.) |
OUT1, OUT2:Short-circuit protection | Incorporated |
Extraneous light monitor output | NPN open-collector transistor ・Maximum sink current: 100 mA ・Applied voltage: 40 V DC or less (between extraneous light monitor output and 0 V) ・Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current) |
Extraneous light monitor output:Output operation | ON when modulated beam other than its own (including auxiliary sensor's) light is received |
Response time | 80 ms or less |
Operation indicators:OUT 1 area | Red LED (lights up when the beam is received in the effective OUT 1 areas) |
Operation indicators:OUT 2 area | Yellow LED (lights up when the beam is received in the effective OUT 2 areas) |
Sensitivity adjuster | Continuously variable adjusters (OUT 1, adjacent right OUT 1, adjacent left OUT 1 and OUT 2 areas are adjusted independently.) |
External sensitivity adjustment function | Sensitivity adjustment is possible with an analog input. |
Sensing area | Four sensing areas are selectable with dip switches. |
Sleep function | Operating / sleep selectable with external input |
Automatic Interference prevention function | Optical interference from up to 25 units is prevented. |
Protection | IP65 (IEC) |
Ambient temperature | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉ |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Ambient illuminance | Incandescent light: 3,000 lx or less at the light-receiving face |
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
Insulation resistance | 20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure |
Vibration resistance | 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (20 G max.) in X, Y and Z directions for two hours each |
Shock resistance | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each |
Emitting element | Infrared LED (Peak emission wavelength: 950 nm 0.037 mil, modulated) |
Material | Enclosure: ABS, Lens: Acrylic, Cover: Polycarbonate |
Cable | For input and output: 0.18 mm2 9-core (PX-24ES and PX-23ES: 12-core) cabtyre cable, 0.5 m 1.640 ft long For auxiliary sensor connection: 0.18 mm2 10-core connector attached cabtyre cable, 0.5 m 1.640 ft long10-core connector attached cabtyre cable, 0.5 m 1.640 ft long |
Cable extension | Extension up to total 100 m 328.084 ft (10 m 32.808 ft for auxiliary sensor connection) is possible with 0.3 mm2, or more, cable. |
Weight | Net weight: 210 g approx. Gross weight: 390 g approx. |
Accessory | MS-PX-2 (Main sensor mounting bracket): 1 set, Adjusting screwdriver: 1 pc. |