LS-H91|Digital Laser Sensor LS-400
Download
*Photo may vary from actual product.
This product has been confirmed that it does not contain the 6 substances specified in EU RoHS Directive 2011/65/EU and the 4 substances specified in 2015/863/EU.
Product Number | LS-H91 |
---|---|
Part Number | LS-H91 |
Product | Digital Laser Sensor |
Details | Sensor head (Coaxial retroreflective type) |
Product Name | Digital Laser Sensor LS-400 |
*Specifications and design of the products are subject to change without notice for the product improvement.
Spec Detail
Specifications and design of the products are subject to change without notice for the product improvement.
Item | Specifications |
---|---|
Part Number | LS-H91 |
Product Number | LS-H91 |
Products Name | Digital Laser Sensor |
Product details | Sensor head (Coaxial retroreflective type) |
The price of the product | Please contact our office |
Applicable amplifiers | LS-401(P), LS-401(P)-C2, LS-403 |
Sensing range:U-LG mode | 0.1 to 7 m 0.328 to 22.966 ft (Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity. |
Sensing range:STD mode | 0.1 to 5 m 0.328 to 16.404 ft (Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity. |
Sensing range:FAST mode | 0.1 to 3 m 0.328 to 9.843 ft (Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity. |
Sensing range:H-SP mode | 0.1 to 3 m 0.328 to 9.843 ft (Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity. |
Operation indicator | Orange LED (lights up when the amplifier output is ON) |
Laser emission indicator | Green LED (lights up during laser emission) |
Spot-shape adjuster | - |
Protection | IP40 (IEC) |
Ambient temperature | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℉ |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Ambient illuminance | Incandescent light: 3,000 lx or less at the light-receiving face |
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
Insulation resistance | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
Vibration resistance | 10 to 500 Hz frequency, 1.5 mm double amplitude or maximum acceleration 98 m/s2 in X, Y, and Z direction for 2 hours each. |
Shock resistance | 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each |
Emitting element:IEC / EN / JIS / GB / KC standards conforming type | Red semiconductor laser, Class 2 (IEC / EN / JIS / GB / KC) (Max. output: 3 mW Peak emission wavelength: 655 nm 0.026 mil) |
Emitting element:FDA / IEC / EN / JIS standards conforming type | Red semiconductor laser, Class 2 (FDA / IEC / EN / JIS) (Max. output: 3 mW Peak emission wavelength: 655 nm 0.026 mil) (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 56, dated July 26, 2001, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). For details, refer to the Laser Notice No. 56. |
Material | Enclosure: PBT (Mounting part: PEI) Lens cover: Acrylic |
Cable | 0.1 mm2, single core two parallel shielded cables, 2 m 6.562 ft long (Connector for amplifier attached) (Note) Cable cannot be extended. |
Weight | Net weight: 30 g approx Gross weight: 55 g approx |
Accessory | Warning label 1 set (IEC / EN / JIS / GB / KS) |