LS-401-C2|Digital Laser Sensor LS-400
Download
*Photo may vary from actual product.
This product has been confirmed that it does not contain the 6 substances specified in EU RoHS Directive 2011/65/EU and the 4 substances specified in 2015/863/EU.
Product Number | LS-401-C2 |
---|---|
Part Number | LS-401-C2 |
Product | Digital Laser Sensor |
Details | Amplifier (Cable type) |
Product Name | Digital Laser Sensor LS-400 |
*Specifications and design of the products are subject to change without notice for the product improvement.
Spec Detail
Specifications and design of the products are subject to change without notice for the product improvement.
Item | Specifications |
---|---|
Part Number | LS-401-C2 |
Product Number | LS-401-C2 |
Products Name | Digital Laser Sensor |
Product details | Amplifier (Cable type) |
The price of the product | Please contact our office |
Operation indicator | Orange LED (lights up when output 1 and output 2 are ON) |
Laser emission indicator | Green LED (lights up during laser emission) |
Ambient temperature | -10 to +55 ℃ +14 to +131 ℉ (If 4 to 7 units are mounted close together: -10 to +50 ℃ +14 to +122 ℉ , if 8 to 16 units are mounted close together: -10 to +45 ℃ +14 to +113 ℉ ) (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉ |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
Insulation resistance | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
Vibration resistance | 10 to 150 Hz frequency, 0.75 mm double amplitude or maximum acceleration 49 m/s2 in X, Y, and Z direction for 2 hours each. |
Shock resistance | 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each |
Material | Enclosure: Heat-resistant ABS Transparent cover: Polycarbonate Push button switch: Acrylic Jog switch: ABS |
Cable | 0.15 mm2 5-core cabtyre cable, 2 m 6.562 ft long |
Weight | Net weight: 65 g approx Gross weight: 75 g approx |
Supply voltage | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
Current consumption | Normal operation: 950 mW or less (Current consumption 40 mA or less at 24 V supply voltage) ECO mode: 780 mW or less (Current consumption 33 mA or less at 24 V supply voltage) |
Outputs(Output 1, Output 2) | NPN open-collector transistor - Maximum sink current: 100 mA (Note) - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1.5 V or less [at 100 mA (Note) sink current] (Note) 50 mA if 5 to 8 connector type amplifiers are connected in cascade , and 25 mA if 9 to 16 connector type amplifiers are connected in cascade. |
Outputs(Output 1, Output 2):Output operation | Selectable either Light-ON or Dark-ON, with jog switch |
Outputs(Output 1, Output 2):Short-circuit protection | Incorporated |
Response time | 80 micro s or less (H-SP), 150 micro s or less (FAST), 500 micro s or less (STD), 4 ms or less (U-LG) selectable with jog switch |
External input(Laser emission halt Full-auto teaching / Limit teaching) | NPN non-contact input - Signal condition High: +5 V to +V DC or open, Low: 0 to +2 V DC (source current 0.5 mA or less) - Input impedance: 10 kOhm approx. |
Select indicator | Yellow LED (lights up when either output 1 or output 2 is selected) |
MODE indicator | RUN: Green LED TEACH, L/D, TIMER, CUST, PRO: Yellow LED |
Digital display | 4 digit (green) + 4 digit (red) LED display |
Sensitivity setting | Normal mode: 2-level teaching / Limit teaching / Full-auto teaching / Manual adjustment Window comparator mode: Teaching (1-level, 2-level, 3-level) / Manual adjustment Hysteresis mode: Teaching (1-level, 2-level, 3-level) / Manual adjustment Differential mode: 5-level settings |
Fine sensitivity adjustment function | Incorporated |
Timer function | Incorporated with variable ON-delay / OFF-delay / ONE SHOT timer, switchable either effective or ineffective. |
Timer function:Time | 1 to 9,999 ms |
Automatic Interference prevention function | Incorporated [Up to four sets of sensor heads can be mounted close together. (However, disabled when in H-SP mode)] |
Cable extension | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. |