Panasonic Industry / Automation Controls
Panasonic Industry / Automation Controls

For small diameter tubes Optical Bubble Sensor BE-A

  • Basic Information

  • Applications

  • Order guide

  • Specifications

  • Dimensions

------------------------------ Tab1 showing ------------------------------

Basic Information

Fits perfectly with applicable tube sizes!
Detects liquid and air bubbles without fail!

CE,UKCA Approved

------------------------------ Tab2 showing ------------------------------

Applications

Liquid dispensing instrument

Liquid dispensing instrument

Analyzer

Clinical laboratory instrument

------------------------------ Tab3 showing ------------------------------

Order guide

TypeAppearanceModel No.OutputOutput
operation
for ø2 mm
ø0.078 in
tube

BE-A201NPN open-collector transistorSwitchable either Liquid-absent-ON or Liquid-present-ON
BE-A201PPNP open-collector transistor
for ø3 mm
ø0.125 in
tube

BE-A301NPN open-collector transistor
BE-A301PPNP open-collector transistor
for ø4 mm
ø0.156 in
tube

BE-A401NPN open-collector transistor
BE-A401PPNP open-collector transistor

------------------------------ Tab4 showing ------------------------------

Specifications

Typefor ø2 mm ø0.078 in tubefor ø3 mm ø0.125 in tubefor ø4 mm ø0.156 in tube
Model No.NPN outputBE-A201BE-A301BE-A401
PNP outputBE-A201PBE-A301PBE-A401P
Applicable regulationsCE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)
Detectable air gap
(Note 2)
0.8 mm 0.032 in or more
Sensing objectLiquid (Note 3)
Applicable tube dia.
(Note 4)
Outer dia.ø2 mm ±0.2 mm
ø0.078 in ±0.008 in
ø3 mm ±0.2 mm
ø1/8 in ±0.008 in
ø4 mm ±0.15 mm
ø5/32 in ±0.006 in
Inner dia.ø1 mm ±0.2 mm
ø0.039 in ±0.008 in
ø2 mm ±0.2 mm
ø1/16 in ±0.008 in
ø2.4 mm ±0.1 mm
ø3/32 in ±0.004 in
Applicable tube type
(Note 4)
Transparent resin tube (equivalent to PFA)Transparent resin tube
(equivalent to flexible PVC)
Supply voltage5 to 24 V DC ±10 % Ripple P-P 10 % or less
Current consumption15 mA or less
Output
(Incorporated with 2 outputs)
<NPN output type>
NPN open-collector transistor
•Maximum sink current: 50 mA
•Applied voltage: 30 V DC or less (between output and 0 V)
•Residual voltage: 2 V or less (sink current at 50 mA) 1 V or less (sink current at 16 mA)

<PNP output type>
PNP open-collector transistor
•Maximum source current: 50 mA
•Applied voltage: 30 V DC or less (between output and + V)
•Residual voltage: 2 V or less (source current at 50 mA) 1 V or less (source current at 16 mA)
 Output
operation
Switchable either Liquid-absent-ON or Liquid-present-ON
Short-circuit
protection
Incorporated
Response time
(Note 5)
When
detecting bubble
30 μs or less20 μs or less
When
detecting liquid
80 μs or less
Operation indicatorOrange LED (lights up with absent liquid)
Protection circuitsPower supply reverse polarity protection , Output reverse polarity protection
Environmental
resistance
ProtectionIP40 (IEC)
Ambient
temperature
(Note 6)
-25 to +55 ℃ -13 to +131 ℉ (No dew condensation or icing allowed),
Storage: -30 to +80 ℃ -22 to +176 ℉
Ambient
humidity
35 to 85 % RH, Storage: 35 to 85 % RH
Ambient
illuminance
Fluorescent light: 1,000 ℓx at the light-receiving face
Voltage
withstandability
1,000 V AC for between one min. between all supply terminals connected together and enclosure
Insulation
resistance
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
Vibration
resistance
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude or maximum acceleration
49 m/s2, in X, Y and Z directions for two hours each
Shock
resistance
100 m/s2 acceleration in X, Y, and Z directions three times each
Emitter elementInfrared LED(Peak emission wavelength: 855 nm 0.034 mil, non-modulated)
MaterialEnclosure: PBT, Tube holder: Polyamide, Indicator: Polycarbonate
Cable0.09 mm2 4-core cabtyre cable 1 m 3.280 ft
Cable extension (Note 7)Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Clamping torque0.5N•m or less
WeightNet weight: 15 g approx., Gross weight: 25 g approx.

Notes:

1)Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.

2)Sensing air gap refers to the width of an air bubble formed in the entire area of the inner diameter of the tube. Please note that this product cannot sense very small air bubbles or water drops. Refer to the figure 1 and 2.

3)Sensing is affected by dirt or residues adhered to the inner wall of the tube. Please maintain the tube regularly.

4)When using a tube out of specifications or it doesn't have a smooth surface, please test sensing on the actual machine before use.

5)Actual response time may differ from specification (typical example using applicable tube) due to dimension, light transmission or surface state of test tube in use.

6)Liquid being detected should also be kept within the rated ambient temperature range.

7)Confirm that the power supply voltage at the end of cable is more than 4.5 V when using an extension of over 20 m 65.167 ft.

------------------------------ Tab5 showing ------------------------------

Dimensions

  • Unit: mm in

BE-A201(P)

For ø2 mm ø0.078 in tube

BE-A201(P)

BE-A301(P)

For ø3 mm ø0.125 in tube

BE-A301(P)

BE-A401(P)

For ø4 mm ø0.156 in tube

BE-A401(P)