Applicable models

Thru-beam type

Basic specificationsApplicable
fiber length
Model No.Fiber cable
length
Free-cutProtective tube
extension length
Sleeve length
(mm)
Sensing range
(mm)
FX-500 series
(STD)(Note 1)
Max.
(m)
Unit
(m)
FT-14010m--19,600(Note 2)301
FT-302m---400100.1
FT-312m--315301
FT-31S2m-40mm(Note 3)315301
FT-31W2m--260201
FT-322m--3,000301
FT-402m---1,200100.1
FT-40V1m---2706.50.1
FT-422m--1,130301
FT-42S2m-40mm(Note 3)1,130301
FT-42W2m--800201
FT-432m--1,400301
FT-45X1m---1,200100.5
FT-A112m--3,600(Note 2)101
FT-A11W2m--3,600(Note 2)101
FT-A322m--3,600(Note 2)101
FT-A32W2m--3,600(Note 2)101
FT-AL052m--860201
FT-E131m-5mm15100.5
FT-E231m-5mm75100.5
FT-F932m1m(Note 4)--251
FT-H13-FM22m--700201
FT-H20-J50-S500mm(Note 5)--4706.50.1
FT-H20-M11m---5406.50.1
FT-H20-VJ80-S800mm(Note 5)--6006.50.1
FT-H20W-M11m---4706.50.1
FT-H30-M1V-S1m---2706.50.1
FT-H35-M22m---4306.50.1
FT-H35-M2S62m--55mm4306.50.1
FT-HL80Y2m(Note 6)1.5m(Note 4)-3,600(Note 2)301
FT-J82m---301
FT-J92m---301
FT-KS402m--3,600(Note 2)101
FT-KV262m--710101
FT-KV26H12m--630101
FT-KV402m--3,600(Note 2)101
FT-KV40W2m--3,600(Note 2)101
FT-L80Y2m(Note 6)1.5m(Note 4)-3,600(Note 2)301
FT-R312m--270301
FT-R402m--930301
FT-R41W2m--800201
FT-R42W2m--2,200201
FT-R432m--720301
FT-R44Y2m--720301
FT-R60Y2m--2,100301
FT-S11500mm---90301
FT-S202m---400100.1
FT-S212m--315301
FT-S21W2m--260201
FT-S222m--450301
FT-S302m---1,200100.1
FT-S31W2m--800201
FT-S322m--3,100301
FT-V232m-20mm450301
FT-V24W2m-15mm110101
FT-V252m-15mm240301
FT-V302m-20mm680301
FT-V402m--3,500301
FT-V80Y2m(Note 6)1.5m(Note 4)-3,600(Note 2)301
FT-Z20HBW1m--260201
FT-Z20W1m--620201
FT-Z302m--2,100301
FT-Z30E2m--3,500301
FT-Z30EW2m--3,400201
FT-Z30H2m--3,500301
FT-Z30HW2m--3,500201
FT-Z30W2m--1,500201
FT-Z40HBW2m--800201
FT-Z40W2m--1,500201
FT-Z802Y2m--3,100301

Models which can have extended sleeve : FT-31S, FT-42S
Models which can have extended protective tube (fluorine resin) : FT-F93, FT-HL80Y, FT-L80Y, FT-V80Y

Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20% max. depending upon how the fiber is cut.

Note 2:The fiber cable length practically limits the sensing range.

Note 3:Applicable sleeve lengh is from 10 to 120 mm 0.394 to 4.724 in and in units of 10 mm 0.394 in.

Note 4:Applicable protective lengh is up to 10 m 32.808 ft and in units of 0.5 m 1.640 ft.

Note 5:Fiber length (fixed-length) for heat-resistant fiber side. Fiber length for ordinary temperature side is 2 m 6.562 ft (free-cut).

Note 6:The allowable cutting range is 500 mm 19.685 in from the end that the amplifier inserted.

Return to Applicable models

Reflective type

Basic specificationsApplicable
fiber length
Model No.Fiber cable
length
Free-cutProtective tube
extension length
Sleeve length
(mm)
Sensing range
(mm)
FX-500 series
(STD)(Note 1)
Max.
(m)
Unit
(m)
FD-302m---160100.1
FD-312m--125301
FD-31W2m--80201
FD-32G2m--200301
FD-32GX1m300mm(Note 3)-200301
FD-34G2m--90301
FD-402m---160100.1
FD-412m--125301
FD-41S2m-40mm(Note 2)125301
FD-41SW2m-40mm(Note 2)80201
FD-41W2m--270201
FD-42G2m--200301
FD-42GW2m--150201
FD-602m--520100.1
FD-612m--450301
FD-61S2m-40mm(Note 2)420301
FD-61W2m--270201
FD-622m--520301
FD-64X1m---280100.5
FD-A162m--200301
FD-AL112m--320201
FD-E131m--3mm1230.1
FD-E231m--5mm5530.1
FD-EG30500mm---4830.1
FD-EG30S1m--15mm5030.1
FD-EG31500mm---2030.1
FD-F42m---101
FD-F412m---101
FD-F715m3m(Note 3)--251
FD-FA932m---101
FD-H13-FM22m--350201
FD-H18-L312m--1651
FD-H20-211m---2306.50.1
FD-H20-M11m---3306.50.1
FD-H25-L433m---1.5 to 2650.1
FD-H25-L453m---5 to 4250.1
FD-H30-KZ1V-S1m---20 to 2006.50.1
FD-H30-L322m---1751
FD-H30-L32V-S3m---850.1
FD-H35-20S1m--90mm2606.50.1
FD-H35-M22m---2606.50.1
FD-H35-M2S62m--55mm2606.50.1
FD-HF40Y2m500mm--51
FD-KZ50V1m---20 to 2006.50.1
FD-L102m--0 to 551
FD-L10V3m---0 to 850.1
FD-L112m--0 to 9.551
FD-L12W1m--851
FD-L20H2m--3051
FD-L212m--1.5 to 1651
FD-L21W2m--3 to 1451
FD-L22A2m--0 to 2451
FD-L233m--0 to 2951
FD-L30A3m--0 to 4351
FD-L31A3m--4 to 3351
FD-L32H4m--0 to 5651
FD-R31G2m--170301
FD-R32EG500mm---4530.1
FD-R33EG500mm---1930.1
FD-R34EG500mm---3830.1
FD-R412m--210301
FD-R602m--290301
FD-R61Y2m--280301
FD-S211m---80201
FD-S302m---160100.1
FD-S312m--125301
FD-S322m--420301
FD-S32W2m--270201
FD-S33GW2m--150201
FD-S34G2m--90301
FD-S60Y2m(Note4)1.5m(Note3)-320301
FD-V302m-15mm65301
FD-V30W2m-15mm20101
FD-V502m-20mm120301
FD-Z20HBW1m--2 to 85201
FD-Z20W1m--1 to 65201
FD-Z40HBW2m--260201
FD-Z40W2m--190201
FD-Z50HW2m--10 to 650201

Models which can have extended sleeve : FD-41S, FD-41SW, FD-61S
Models which can have extended protective tube (fluorine resin) : FD-F71
Models which can have extended stainless jacket sheath : FD-32GX

Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20% max. depending upon how the fiber is cut.

Note 2:Applicable sleeve lengh is from 10 to 120 mm 0.394 to 4.724 in and in units of 10 mm 0.394 in.

Note 3:

Applicable protective lengh is up to 10 m 32.808 ft and in units of 0.5 m 1.640 ft . (however, FD-32GX is in units of 0.1 m 0.328 ft.)

Note 4:The allowable cutting range is 500 mm 19.685 in from the end that is inserted to the amplifier.

Return to Applicable models

Retroreflective type

Basic specificationsApplicable
fiber length
Model No.Fiber cable
length
Free-cutProtective tube
extension length
Sleeve length
(mm)
Sensing range
(mm)
FX-500 series
(STD)(Note 1)
Max.
(m)
Unit
(m)
FR-KZ22E2m--15 to 310101
FR-KZ50E2m--20 to 300101
FR-KZ50H2m--20 to 300101
FR-Z50HW2m--100 to 990101

Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20% max. depending upon how the fiber is cut.

MENU