Sensor-PLC Connection System SC
Download
-
Basic Information
-
Order guide
-
Option
-
Specifications
-
Dimensions
-
Circuit/ Wiring
-
Cautions For Use
Partly Order Discontinued
Last time buy (JST)
September 30, 2015
Discontinued products:SC-T8J、SC-T8J-P、SC-TP8J
------------------------------ Tab1 showing ------------------------------
Basic Information
Up to 16 I/O devices can be connected at once using MIL connectors
CE,UKCA Approved
CE, UKCA : SC-MIL/T1J(-P) only
Features
Up to 16 I/O devices can be connected at once using MIL connectors
Up to 16 units, such as fiber sensors FX-500/550/410/300/311 series, digital laser sensors LS-500/400 series, digital pressure sensors DPS-401/402 and compact inductive proximity sensors GA-311, can be connected side-by-side configuration without tools in a main unit. Also, dispersed mounting is possible using a separate unit. In addition, using the connector input / output extension unit, photoelectric sensors, micro photoelectric sensors, inductive proximity sensors, pressure sensors, or any other type of sensor or switch can be one-touch connected to an output device.
------------------------------ Tab2 showing ------------------------------
Order guide
Designation | Appearance | Model No. | Description | |
---|---|---|---|---|
Main unit (Note1) | SC-MIL | The MIL connector allows up to 16 input / output device connections to a PLC or custom circuit board, in a single step. | ||
Separate unit (Note1) | SC-MIL-S | Distributed installations are possible through the use of a main unit and MIL connectors. | ||
1-channel connector input extension unit | SC-T1J | For NPN output devices | Allows the connection of input device, such as sensor or switch. Incorporates a power indicator and an input signal indicator (1 ch). | |
SC-T1J-P | For PNP output devices | |||
e-CON 1-channel connector input extension unit | SC-E1 | This extension unit can be connected to commercially available devices including an NPN output type or DC 2-wire type sensor. Includes power and input signal indicators (for one channel). When using in combination with the SC-GU3 series, use with the SC-71. | ||
e-CON 8-channel connector input extension unit | SC-E81 | This extension unit can be connected to eight NPN output type devices. Includes power and input signal indicators (for eight channels). | ||
e-CON 8-channel connector input extension unit (Without an input signal indicator) | SC-E82 | This extension unit can be connected to eight commercially available devices and output devices including an NPN/PNP output type sensors, switches or DC 2-wire sensors. Includes a power indicator. Does not include an input signal indicator. | ||
Non-line connector | CN-70 | This one-touch connector is used to connect the main unit to the following devices: The FX-501/502/301/305/311 and FX-411/412 fiber sensor, the LS-401/403 laser sensor, digital pressure sensor DPS-401/402, the GA-311 compact inductive proximity sensor, the FX-CH(-P) bank selection unit and the SC-T1J(-P) 1-channel connector input extension unit. (Note 2, 3) | ||
End plates | MS-DIN-E 2 pcs. per set | When SC series units are connected on a DIN rail, these end plates clamp amplifiers into place on both sides. Make sure to use end plates when cascading multiple amplifiers together. |
Notes:
1)Conditions of connectable DC 2-wire type input device
• Leak current: 1 mA or less (when the power is OFF), Offset voltage: 3 V or less (when the power is ON)
• Product whose load current range includes 5 to 8 mA
2)The non-line connector now can be used with 4-pin types, such as the FX-305 and LS-401, since its production run starting in August 2004.
3)The 2-output type can output the output 1 (OUT 1) only from SC-MIL. There is no connection for output 2 (OUT2).
------------------------------ Tab3 showing ------------------------------
Option
Designation | Appearance | Model No. | Description | |
---|---|---|---|---|
4-pin type snap male connector (Note4) | SL-CP1 (White) 10 pcs. per set | For 0.08 to 0.2 mm2 (Conductor cross-section area) Wire diameter: ø0.7 to ø1.2 mm ø0.028 to ø0.047 in | Snap male connectors are utilized to connect input / output devices to both the 1-channel and the 8-channel connector input units, as well as to the 8-channel connector combined input / output unit. The 1-channel connector input extension unit includes one SL-CP1. | |
SL-CP2 (Black) 10 pcs. per set | For 0.3 mm2 (Conductor cross-section area) Wire diameter: ø1.1 to ø1.6 mm ø0.043 to ø0.063 in | |||
SL-CP3 (Greenish blue) 10 pcs. per set | For 0.5 mm2(Conductor cross-section area) Wire diameter: ø1.7 to ø2.5 mm ø0.067 to ø0.098 in | |||
Compatible installation tool for SC | SC-BUX10 10 pcs. per set | This tool is used to install SC-MIL-S into the SC-GU3 series. |
Note: Exclusive pliers are also available.
------------------------------ Tab4 showing ------------------------------
Specifications
Sensor units
Type | Main unit | Separate unit |
---|---|---|
Model No. | SC-MIL | SC-MIL-S |
CE marking directive compliance | EMC Directive, RoHS Directive | - |
Supply voltage | 12 to 24 V DC ±10 % (Note 2) | Depends on the supply voltage from SC-MIL |
Allowable through current (Note 3) | 2 A or less (Same as maximum permissible current consumption of all units connected to SC-MIL.) | 1 A or less (Same as maximum permissible current consumption of all units connected to SC-MIL-S.) |
Signal channel No. | Connectable up to 16 channels (The signal from up to 16th point (counting from unit adjacent to SC-MIL) of all units connected to SC-MIL is transferred. However, the signal thereafter is not transferred. Note that SC-MIL and SC-MIL-S do not occupy any signal point.) | |
Max. distance between units | 10 m 32.808 ft or less (the distance between SC-MIL and PLC and that between SC-MIL and SC-MIL-S put together) | |
Ambient temperature | –10 to +45 ℃ +14 to +113 ℉ (No dew condensation or icing allowed), Storage: –20 to +70 ℃ –4 to +158 ℉ | |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | |
Material | Enclosure: Heat-resistant ABS | |
Net weight | 25 g approx. | 20 g approx. |
Accessory | Connector protection seal: 1 pc. |
Notes: 1)Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
2)The plug-in sensor main unit SC-MIL incorporates a cable lead-out connector in addition to the MIL connector, which allows to receive the supply voltage from the separate power supply.
3) When either the permissible current amount of power supply unit or the permissible current amount of cable to be connected is less than allowable through current value, adjust the current to the smallest value.
3)When either the permissible current amount of power supply unit or the permissible current amount of cable to be connected is less than allowable through current value, adjust the current to the smallest value.
Connector input extension units
Type | Connector input extension units | |
---|---|---|
For NPN output devices | For PNP output devices | |
1 channel | 1 channel | |
Model No. | SC-T1J | SC-T1J-P |
CE marking directive compliance | EMC Directive, RoHS Directive | |
Supply voltage | 12 to 24 V DC ±10 % | |
Current consumption (Note 2) | 20 mA or less (when all indicators light up) | |
Signal channel No. | 1 input | |
Connectable device | NPN open-collector, or DC 2-wire output type sensor, or switch etc. | PNP open-collector, or DC 2-wire output type sensor, or switch etc. |
Supply current for units (Note 3) | 100 mA or less | |
Power indicator | Green LED (Lights up when the power is ON) | |
Input indicator | Green LED (Lights up when each channel input is ON) | |
Ambient temperature | –10 to +45 ℃ +14 to +113 ℉ (No dew condensation or icing allowed), Storage: –20 to +70 ℃ –4 to +158 ℉ | |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | |
Material | Enclosure: Heat-resistant ABS | |
Net weight | 10 g approx. | |
Accessory | SL-CP1 (Snap male connector): 1 pc. |
Notes: 1)Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
2)The current consumption and input current of the input unit connected are not included.
3)Set the maximum current passing through input / output line to 50 mA or less.
e-CON connector input extension unit
Type | e-CON 1-channel connector input extension unit |
---|---|
Model No. | SC-E1 |
Supply voltage | 12 to 24 V DC ±10 % |
Current consumption | 20 mA or less (with all indicators on) (Note 1) |
Input | Connectable devices: NPN open-collector transistor output type (Input 1) and DC 2-wire output type (Input 2) sensors (Note 2), switches, and other devices Current supply for input device: 100 mA or less Input impedance: Approx. 17 kΩ (Input 1) or approx. 3.2 kΩ (Input 2) |
Output | NPN open-collector transistor • Maximum sink current: 50 mA • Applied voltage: 30 V DC or less (between output and 0 V) • Residual voltage: 1.5 V or less (with sink current of 50 mA) |
Power indicator | Green LED (lights up when the power is ON) |
Input indicator | Green LED (lights up when input is being received by unit) |
Ambient temperature | –10 to +45 ℃ +14 to +113 ℉ (No dew condensation or icing allowed), (If 4 to 7 units are connected in cascade: –10 to +50 ℃ +14 to +122 ℉, if 8 to 16 units are connected in cascade: –10 to +45 ℃ +14 to +113 ℉) Storage: –20 to +70 ℃ –4 to +158℉ |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Material | Enclosure: Flame-resistant PBT, Connector: Polyester |
Weight | Net weight: 15 g approx., Gross weight: 40 g approx. |
Accessory | Connector (e-CON): 1 |
Notes:
1)Does not include current consumption or input current for connected input devices.
2)Conditions of connectable DC 2-wire type input device
• Leak current: 1 mA or less (when the power is OFF),
Offset voltage: 3 V or less (when the power is ON)
• Product whose load current range includes 5 to 8 mA
e-CON connector input extension unit
Type | e-CON 1-channel connector input extension unit |
---|---|
Model No. | SC-E81 |
Supply voltage | 12 to 24 V DC ±10 % |
Current consumption | 20 mA or less (with all indicators on) (Note 1) |
Number of signals | 8 inputs (Note 2) |
Input | Connectable devices: NPN open-collector transistor output type sensors, switches, and other devices Current supply for input devices: 800 mA or less (total for 8 inputs) Input impedance: 17 kΩ approx. |
Output | NPN open-collector transistor • Maximum sink current: 50 mA • Applied voltage: 30 V DC or less (between output and 0 V) • Residual voltage: 1.5 V or less (with sink current of 50 mA) |
Power indicator | Green LED (lights up when the power is ON) |
Input indicator | 8 green LEDs (light up when input is received from the corresponding channel) |
Ambient temperature | –10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), (If 4 to 7 units are connected in cascade: –10 to +50 ℃ +14 to +122 ℉, if 8 to 9 units are connected in cascade: –10 to +45 ℃ +14 to +113 ℉) Storage: –20 to +70 ℃ –4 to +158℉ |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Material | Enclosure: Polycarbonate, Connector: Polyester |
Weight | Net weight: 40 g approx., Gross weight: 85 g approx. |
Notes:
1)Does not include current consumption or input current for connected input devices.
2)Uses eight channels of signaling, regardless of the number of connected input devices.
Designation | e-CON 8-channel connector input extension unit (without an input signal indicator) |
---|---|
Model No. | SC-E82 |
Supply voltage | 5 to 24 V DC ±10 % |
Current consumption | 7 mA or less |
Number of signals | 8 inputs (Note 1) |
Input | Connectable devices: NPN/PNP open-collector transistor output type sensors, switches, etc. and commercially available devices and output devices including a DC 2-wire type sensor (Note 2) Current supply for input devices: 800 mA or less (total for 8 inputs) |
Power indicator | Green LED (Lights up when the power is ON) |
Ambient temperature | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), (If 4 to 7 units are connected in cascade: -10 to +50 ℃ +14 to +122 ℉, if 8 to 9 units are connected in cascade: -10 to +45 ℃ +14 to +113 ℉) Storage: -20 to +70 ℃ -4 to +158 ℉ |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Material | Enclosure: Polycarbonate, Connector: Polyester |
Weight | Net weight: 40 g approx., Gross weight: 85 g approx. |
Notes:
1)Uses eight channels of signaling, regardless of the number of connected input devices.
2)When using in combination with the SC-GU3 series, it cannot use as a commercially available device including a DC 2-wire type sensor or output.
Non-line connector
Type | Non-line connector |
---|---|
Model No. | CN-70 |
Applicable unit | Refer to the list of "Applicable unit of non-line connector" |
Supply voltage | Depends on the supply voltage from SC-MIL |
Supply current for units | 100 mA or less |
Signal channel No. | 1 channel |
Ambient temperature | –10 to +45 ℃ +14 to +113 ℉ (No dew condensation or icing allowed) Storage: –20 to +70 ℃ -4 to +158 ℉ |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Material | Enclosure: ABS |
Weight | Net weight: 4 g approx. |
Notes:
1)Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
2)The non-line connector now can be used with 4-pin types, such as the FX-305 and LS-401, since its production run starting in August 2004.
Applicable unit of non-line connector
Designation | Model No. | Description |
---|---|---|
1-channel input extension units | SC-T1J | For NPN output devices |
SC-T1J-P | For PNP output devices | |
Digital fiber sensors (Note) | FX-501/502 | For NPN output devices |
FX-501P/502P | For PNP output devices | |
FX-551 | For NPN output devices | |
FX-551P | For PNP output devices | |
FX-301(B/G/H) FX-301-HS | For NPN output devices | |
FX-301(B/G/H)P FX-301P-HS | For PNP output devices | |
FX-305 | For NPN output devices | |
FX-305P | For PNP output devices | |
FX-411(B/G) FX-412(B/G) | For NPN output devices | |
FX-411(B/G)P | For PNP output devices | |
Manually set fiber sensors | FX-311(B/G) | For NPN output devices |
FX-311(B/G)P | For PNP output devices | |
Digital fiber sensors for leak detection fiber / liquid detection fiber | FX-301-F | For NPN output devices |
FX-301P-F | For PNP output devices | |
Digital laser sensors (Note) | LS-501 | For NPN output devices |
LS-501P | For PNP output devices | |
LS-401/403 | For NPN output devices | |
LS-401P | For PNP output devices | |
Digital pressure sensor | DPS-401/402 | For NPN output devices |
Compact inductive proximity sensor | GA-311 | For NPN output devices |
Bank selection unit | FX-CH | For NPN input devices |
FX-CH-P | For PNP input devices |
Notes:The 2-output type can output the output 1 (OUT 1) only from SC-MIL.
There is no connection for output 2 (OUT2).
------------------------------ Tab5 showing ------------------------------
Dimensions
- Unit: mm in
SC-MIL
Main unit
With power supply cover removed.
SC-MIL-S
Separate unit
SC-T1J SC-T1J-P
Connector input extension unit
SC-E1
e-CON 1ch connector input extension unit
SC-E81 SC-E82
e-CON 8ch connector input extension unit
Note: SC-E82 is not equipped with an input indicator.
CN-70
Non-line connector
MS-DIN-E
End plate (Optional)
Material: Polycarbonate
------------------------------ Tab6 showing ------------------------------
I/O Circuit and Wiring diagrams
SC-MIL SC-MIL-S
Main unit Separate unit
Pin layout diagram for MIL connector pins
*The MIL connector pin layout is compatible with SL-BMW sensor block,
which is utilized to simplify wiring and save space.
*+V (pin No.10 and 20) and 0 V (pin No. 9 and 19) are connected inside the block.
SC-T1J
Connector input extension unit
For NPN output devices
Snap male connector pin position
Pin No. | SC-T1J |
---|---|
1 | +V |
2 | GND |
3 | Input 1 |
4 | Input 2(Note 1) |
Notes:
1)For DC 2-wire type input device
Conditions
• Leak current : 1 mA or less (when the power is OFF)
• Offset voltage : 3 V or less (when the power is ON)
• The product of which the load current range contains 5 to 8 mA.
2)Residual voltage: 1 V or less (at 50 mA sink current)
SC-T1J-P
Connector input extension unit
For PNP output devices
Snap male connector pin position
Pin No. | SC-T1J-P |
---|---|
1 | +V |
2 | GND |
3 | Input 1 |
4 | Input 2(Note 1) |
Notes:
1)For DC 2-wire type input device
Conditions
• Leak current : 1 mA or less (when the power is OFF)
• Offset voltage : 3 V or less (when the power is ON)
• The product of which the load current range contains 5 to 8 mA.
2)Residual voltage: 1 V or less (at 50 mA sink current)
SC-E1 SC-E81
e-CON 1-channel connector input extension unit
e-CON 8-channel connector input extension unit
Notes:
1)Only SC-E1 can be used.
For DC 2-wire type input device (24 V DC only)
• Leak current : 1 mA or less (when the power is OFF)
• Offset voltage : 3 V or less (when the power is ON)
• The product of which the load current range contains 5 to 8 mA.
2)Residual voltage: 1 V or less (at 50 mA sink current)
SC-E82
e-CON 8-channel connector input extension unit
(Without an input signal indicator)
Notes:
1)It depends on the power supply from SC-MIL or SC-GU3-0□.
2)When using a DC 2-wire input device, connect a device recommended load to the outside.
------------------------------ Tab7 showing ------------------------------
Cautions For Use
- Never use this product in a device for personnel protection.
- In case of using devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country.