FV-FR4|One-Touch Connection System Vacuum-resistant Fibers
Download
*Photo may vary from actual product.
This product has been confirmed that it does not contain the 6 substances specified in EU RoHS Directive 2011/65/EU and the 4 substances specified in 2015/863/EU.
Product Number | FV-FR4 |
---|---|
Part Number | FV-FR4 |
Product | Vacuum-resistant flange 4CH |
Details | Atmospheric side and vacuum side are isolated. |
Product Name | One-Touch Connection System Vacuum-resistant Fibers |
*Specifications and design of the products are subject to change without notice for the product improvement.
Spec Detail
Specifications and design of the products are subject to change without notice for the product improvement.
Item | Specifications |
---|---|
Part Number | FV-FR4 |
Product Number | FV-FR4 |
Products Name | Vacuum-resistant flange 4CH |
Product details | Atmospheric side and vacuum side are isolated. |
Applicable fibers | FT-40V, FD-KZ50V, FD-L10V, FT-J9 |
Leakage | 1.0 x 10-10 Pa·m3/s [He] or less (* Measured with a He detector) |
Ambient temperature | -30 to +120℃ -22 to +248℉ (Same for storage. Up to +40 ℃ +104℉ when humidity is high. However, no dew condensation or icing allowed.) |
Ambient humidity | 35 to 85% RH (Same for storage) |
Tightening torque | 9.8 N·m or less (M8 screw) |
Tensile strength | 20 N or less (Atmospheric / vacuum side fiber joint) |
O-ring size | V40 |
Weight | 410 g approx. |
Material | Main unit: Stainless steel (SUS303), Holding bracket: Stainless steel (SUS301), Fiber: Quartz glass, O-ring: Fluororubber |
Recommended thickness of vacuum chamber wall | 3.0 mm 0.118 in or more (Note) : If the vacuum chamber wall is too thick, the FV-FR4 may not be able to connect to the vacuum side fiber. In that case, connect the FV-FR4 to the vacuum side fiber before the installation. |