Basic Information

Settings for up to 16 sensors can be changed at once by means of external signals

UL,CE,UKCA Approved

UL : Recognition

------------------------------ Tab2 showing ------------------------------

Applications

In production lines containing target objects that vary in color from lot to lot, the fiber, sensor's settings must be changed in accordance with the characteristics of the target objects (see illustration below). However, it can be very troublesome to change sensor settings for each different arrangement or type of work. Making these changes to settings takes time and requires extra care, in order to avoid possible malfunctions. The FX-CH series allows preset bank settings to be changed, all in a single step, by utilizing an external signal, without having to handle individual sensors.

------------------------------ Tab3 showing ------------------------------

Order guide

Bank selection units

TypeAppearanceModel No.Description
NPN input

FX-CHBy using an external signal, this unit can change the bank channel settings for up to 16 sensors [of both the digital laser sensor LS-401(P) and digital fi ber sensor FX-301B/G/H(P) (blue / green / infrared)], all in a single step.
PNP inputFX-CH-P

Connectors

DesignationAppearanceModel No.Description
4-pin
type
snap
male
connector

SL-CP1 (Wihte)
[10 pcs. per set]
For 0.08 to 0.2 mm2 (conductor cross-section area)
Wire diameter: ø0.7 to ø1.2 mm ø0.028 to ø0.047 in
This snap male connector is used to connect the channel changing input to the bank selection unit. The bank selection unit includes one SL-CP1.

SL-CP2 (Black)
[10 pcs. per set]
For 0.3 mm2 (conductor cross-section area)
Wire diameter: ø1.1 to ø1.6 mm ø0.043 to ø0.063 in

SL-CP3 (Greenish blue)
[10 pcs. per set]
For 0.5 mm2 (conductor cross-section area)
Wire diameter: ø1.7 to ø2.5 mm ø0.067 to ø0.098 in

Others

DesignationAppearanceModel No.Description
Hook-up pliers for the snap male / female connector

SL-JPC4-pin type hook-up connectors (SL-CP1, SL-CP2) can be connected in one grip.
SL-CP3 exclusive pliers

SL-JPE4-pin type snap male connector (SL-CP3) can connected in one grip.

Quick-connection cables

TypeModel No.Description
Main cable
for FX-CH(-P)
(Note)
CN-73-C1Length: 1 m 3.281 ftThis quick-connection cable is utilized when connecting the digital laser sensor LS-401(P) and the digital fi ber sensor FX-301B/G/H(P) and the bank selection unit FX-CH(-P) together in side-by-side confi guration.
0.15 mm2 3-core cabtyre cable, with connector on one end Cable outer diameter: ø3 mm ø0.118 in
CN-73-C2Length: 2 m 6.562 ft
CN-73-C5Length: 5 m 16.404 ft

Note :Use a sub cable to connect an amplifier.
Refer to the LS series and FX-301B/G/H for details.

Main cable

CN-73-C□

End plates

AppearanceModel No.Description

MS-DIN-E
[Two pcs. per set]
After the FX-CH(-P) and the digital laser sensors and the digital fiber sensors have been attached to the DIN rail, all of these devices must be secured firmly together by placing end plates at each of the ends and sandwiching the FX-CH(-P) and the fiber sensors in between. Ensure that these end plates are used for this purpose.

------------------------------ Tab4 showing ------------------------------

Specifications

TypeNPN inputPNP input
Model No.FX-CHFX-CH-P
Applicable sensorsFX-301B/G/H(P), LS-401(P)
Supply voltage12 to 24 V DC ±10 % Ripple P-P 10 % or less
Current consumption25 mA or less (When all indicators light up)
Bank selection inputLow: 0 to 2 V DC
(Source current: 0.5 mA
Input impedance: 10 kΩ approx.)
High: 5 V to +V DC, or open
High: 4 V to +V DC
(Sink current: 0.5 to 3 mA
Input impedance: 10 kΩ approx.)
Low: 0 to 0.6 V DC, or open
Power indicatorGreen LED (Lights up when the power is ON)
Transmission operation indicatorGreen LED (Lights up when loaded, blinks → lights up when saved)
Pollution degree3 (Industrial environment)
Ambient temperature–10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: –20 to +70 ℃ –4 to +158 ℉
Ambient humidity35 to 85 % RH, Storage: 35 to 85 % RH
EMCEN 61000-6-2, EN 61000-6-4
Voltage withstandability1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
Vibration resistance10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
Shock resistance98 m/s2 acceleration (10 G approx.) in X, Y and Z directions for fi ve times each
MaterialEnclosure: Heat-resistant ABS
Connecting methodConnector (Note 2)
Cable lengthTotal length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
WeightNet weight: 20 g approx., Gross weight: 25 g approx.
DimensionsW10 x H27 x D64.5 mm W0.394 x H1.063 x D2.539 in
AccessorySL-CP1 (4-pin type snap male connector): 1 pc.

Note 1 :Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.

Note 2 :The cable for FX-CH(-P) connection is not supplied as an accessory. Make sure to use the optional quick-connection cable given below.
Main cable (3 core): CN-73-C1 (cable length 1 m 3.281 ft), CN-73-C2 (cable length 2 m 6.562 ft), CN-73-C5 (cable length 5 m 16.404 ft)

Note 3 :Make sure that FX-CH(-P) should be mounted to a 35 mm 1.378 in width DIN rail.

------------------------------ Tab5 showing ------------------------------

Dimensions

  • Unit: mm in

FX-CH FX-CH-P

FX-CH FX-CH-P