------------------------------ Tab1 showing ------------------------------
Basic Information
1.6 times longer sensing range than conventional models
Significantly improved stability and usability
CE,UKCA Approved
Features
Sensing range up to 1.6 times
Ample sensing distance even with thin fiber
The sensing range of the thin reflective type fiber is about 1.6 times longer than that of a conventional product (the sensing range of the standard reflective type fiber is about 1.4 times longer). This adds extra flexibility to the sensor layout.
Fiber | Sensing range (STD mode) | Rate of increase in sensing range | |
---|---|---|---|
FX-551 | FX-501 | ||
FT-31 | 480mm18.898 in | 315mm 12.402 in | 152% |
FT-42 | 1,470mm57.874 in | 1,130mm 44.488 in | 130% |
FD-41 | 200mm7.874 in | 125mm 4.921 in | 160% |
FD-61 | 620mm24.409 in | 450mm 17.717 in | 138% |
When the hysteresis is the same, the higher incident light intensity results in more stable detection.
When the hysteresis is the same, the higher incident light intensity results in more stable detection.
Easy adjustment of beam axis
Thanks to the high emission power, a slight deviation of beam axis causes no problem. It is ideal for use in dusty areas* or for detection through an extremely small slit.
* Need to confirm proper operation in installed condition.
Equipped with a mode to minimize the effect of ambient light
When setting to activate the environment resistance mode in the emission frequency setting, the ambient illuminance for LED lights becomes about 2.5 times higher than that in the normal mode. This reduces erroneous detections caused by LED lights.
Simplified functions for improved operation ease
The FX-500 series and newer models are equipped with only basic functions for improved ease of use. No matter which model you select, they are all easy to use.
MODE NAVI + Direct setting
MODE NAVI uses three indicators and a dual display to show the amplifier’s basic operations. The current operation mode can be confirmed at a glance, so even a first-time user can easily operate the amplifier.
■NAVI display (lights off during RUN mode)
■Direct setting
■List of functions in PRO mode
PRO 1 | Response time setting, timer setting, shift amount setting |
---|---|
PRO 2 | Teaching lock setting, digital display item setting, digital display turning setting, Eco setting |
PRO 3 | Display adjustment setting, reset setting, emission frequency setting, threshold value tracking setting |
No need to specify a main unit or sub unit
All FX-500 amplifiers can be used as either a main unit or a sub unit. Just use a main cable or a sub cable to distinguish the two. This reduces the costs of inventory management.
Wire-saving, space-saving
The quick-connection cables enable reduction in wiring. The connections and man-hours required for the relay terminal block setup can be reduced and valuable space is saved.
* Connection of up to 16 units with FX-500 / FX-400 / DPS-400 / LS-400 is possible.Note:FX-550 series is not equipped with a communication function.When connecting to the host communication units SC-GU3 series, SC-GU2-C and SC-GU1-485, please use FX-500 series.
------------------------------ Tab2 showing ------------------------------
Order guide
Amplifiers
Quick-connection cable is not supplied with FX-551(P). Please order it separately.
Type | Appearance | Model No. | Emitting element | Output |
---|---|---|---|---|
Connector type | FX-551 | Red LED | NPN open-collector transistor | |
FX-551P | PNP open-collector transistor | |||
Cable type | FX-551-C2 | NPN open-collector transistor | ||
FX-551P-C2 | PNP open-collector transistor |
Quick-connection cables
Quick-connection cable is not supplied with the connector type amplifier. Please order it separately.
Type | Model No. | Description | |
---|---|---|---|
Main cable (3-core) | CN-73-C1 | Length: 1 m 3.281 ft | 0.2 mm2 3-core cabtyre cable, with connector on one end Cable outer diameter: ø3.3 mm ø0.130 in |
CN-73-C2 | Length: 2 m 6.562 ft | ||
CN-73-C5 | Length: 5 m 16.404 ft | ||
Sub cable (1-core) | CN-71-C1 | Length: 1 m 3.281 ft | 0.2 mm2 1-core cabtyre cable, with connector on one end Cable outer diameter: ø3.3 mm ø0.130 in Connectable to a main cable up to 15 cables. |
CN-71-C2 | Length: 2 m 6.562 ft | ||
CN-71-C5 | Length: 5 m 16.404 ft |
Main cable
CN-73-C□
Sub cable
CN-71-C□
End plates
End plates are not supplied with the amplifier. Please order them separately when the amplifiers are mounted in cascade.
Appearance | Model No. | Description |
---|---|---|
MS-DIN-E | When cascading multiple amplifiers, or when it moves depending on the way it is installed on a DIN rail, these end plates clamp amplifiers into place on both sides. Make sure to use end plates when cascading multiple amplifiers together. [2 pcs. per set] |
------------------------------ Tab3 showing ------------------------------
Option
Designation | Model No. | Description |
---|---|---|
Amplifier mounting bracket | MS-DIN-2 | Mounting bracket for amplifier |
Amplifier mounting bracket
MS-DIN-2
------------------------------ Tab4 showing ------------------------------
Specifications
Type | Connector type | Cable type | |
---|---|---|---|
Model No. | NPN output | FX-551 | FX-551-C2 |
PNP output | FX-551P | FX-551P-C2 | |
Applicable regulations | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) | ||
Supply voltage | 12 to 24 V DC +10−15 % Ripple P-P 10 % or less | ||
Power consumption | Normal operation: 960 mW or less (current consumption 40 mA or less at 24 V supply voltage) ECO mode: 680 mW or less (current consumption 28 mA or less at 24 V supply voltage) | ||
Output | <PNP output type> PNP open-collector transistor ・Maximum source current: 100 mA ・Applied voltage: 30 V DC or less (between output and +V) ・Residual voltage: 2 V or less (Note 2) (at maximum source current) <NPN output type> NPN open-collector transistor ・Maximum sink current: 100 mA ・Applied voltage: 30 V DC or less (between output and 0 V) ・Residual voltage: 2 V or less (Note 2) (at maximum sink current) | ||
Output operation | Switchable either Light-ON or Dark-ON by L/D mode | ||
Short-circuit protection | Incorporated | ||
Response time | FAST : 60μs or less, STD : 250μs or less, LONG : 2ms or less, U-LG : 4ms or less, HYPR : 24ms or less, selectable | ||
Sensitivity setting | 2-point teaching / Limit teaching / Full-auto teaching / Manual adjustment | ||
Incident light sensitivity setting | Incorporated, 4 steps | ||
Incident light intensity display range | FAST / STD: 0 to 4,000, LONG: 0 to 8,000, U-LG / HYPR: 0 to 9,999 | ||
Timer function | Incorporated with variable OFF-delay / ON-delay / One-shot / switchable either effective or ineffective | ||
Timer period | Timer range "ms" : 1 to 9,999 ms approx., 1 ms approx., Timer range "sec." : 1 to 32 s approx., 1 s approx., Timer range "1/10 ms" : 0.1 to 999.9 ms approx., 0.1 ms approx. (Note 3) | ||
Different frequency interference prevention function (Note 4) | Incorporated (up to 4 units). Note that the response time varies depending on the setting. F-1: 0.8 ms or less, F-2: 0.9 ms or less, F-3: 1.0 ms or less, F-4: 1.7 ms or less | ||
Protection | IP40(IEC) | ||
Ambient temperature | -10 to +55 ℃ +14 to +131 ℉ (If 4 to 7 units are mounted in cascade: -10 to +50 ℃ +14 to +122 ℉ or if 8 to 16 units are mounted in cascade: -10 to +45 ℃ +14 to +113 ℉) (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉ | ||
Vibration resistance | 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (10 G max.) in X, Y and Z directions for two hours each | ||
Shock resistance | 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each | ||
Emitting element (modulated) | Red LED (Peak emission wavelength: 660 nm 0.026 mil) | ||
Material | Enclosure, Case cover: Polycarbonate, Switch: Polyacetal | ||
Cable | - | 0.2 mm2 3-core cabtyre cable, 2 m 6.562 ft long | |
Cable extension | - | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. (however, supply voltage 12 V DC or more) | |
Weight | Net weight: 15 g approx., Gross weight: 55 g approx. | Net weight: 55 g approx., Gross weight: 90 g approx. |
Notes:
1)Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.
2)In case of using the quick-connection cable (cable length 5 m 16.404 ft) (optional).
3)When set to LONG, U-LG, HYPR, IP-F or IP-R, the time range cannot be set to 1/10 ms.
4)This function increases the hysteresis. Check the sensing condition when using the function.
------------------------------ Tab5 showing ------------------------------
Dimensions
- Unit: mm in
FX-551(P)
Amplifier
FX-551(P)-C2
Amplifier
CN-73-C□
Main cable (Optional)
Length L
Model No. | Length L |
---|---|
CN-73-C1 | 1,000 39.370 |
CN-73-C2 | 2,000 78.740 |
CN-73-C5 | 5,000 196.850 |
CN-71-C□
Sub cable (Optional)
Length L
Model No. | Length L |
---|---|
CN-71-C1 | 1,000 39.370 |
CN-71-C2 | 2,000 78.740 |
CN-71-C5 | 5,000 196.850 |
MS-DIN-2
Amplifier mounting bracket (Optional)
Material: Cold rolled carbon steel (SPCC) (Uni-chrome plated)
MS-DIN-E
End plate (Optional)
Material: Polycarbonate
------------------------------ Tab6 showing ------------------------------
I/O Circuit and Wiring diagrams
FX-551(-C2)
NPN output type
I/O circuit diagram
Notes:
1)The quick-connection sub cable does not have +V (brown) and 0 V(blue). The power is supplied from the connector of the main cable.
2)50 mA max., if five amplifiers or more, are connected together.
3)The color code of the connector attached cable is also the same.
Wiring diagram
Note:The quick-connection sub cable does not have a brown and a blue lead wire.
Terminal arrangement diagram
FX-551P(-C2)
PNP output type
I/O circuit diagram
Notes:
1)The quick-connection sub cable does not have +V (brown) and 0 V (blue). The power is supplied from the connector of the main cable.
2)50 mA max., if five amplifiers or more, are connected together.
3)The color code of the connector attached cable is also the same.
Wiring diagram
Note:The quick-connection sub cable does not have a brown and a blue lead wire.
Terminal arrangement diagram
------------------------------ Tab7 showing ------------------------------
Sensing characteristics
Sensing characteristics can be downloaded at catalog download site.
Please contact our office if not listed here.
>>Go to Data download.
------------------------------ Tab8 showing ------------------------------
List of fibers
Response time of FX-550 / FX-550L series is as follows.
Note: FX-550L series does not have FAST mode.
Mode | FAST | STD | LONG | U-LG | HYPR |
---|---|---|---|---|---|
Response time | 60μs or less | 250μs or less | 2ms or less | 4ms or less | 24ms or less |
List of fiber
- Retroreflective Type
- Chemical-resistant
- Heat-resistant
- One-Touch Connection System Vacuum-resistant Fibers
- Vacuum-resistant
Square Head Fiber
■Thru-beam type(one pair set)
Type | Model No. | Sensing range(mm)(Note1) | |||||
---|---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | |||
Square head | M3 | FT-R31 | 310 | 510 | 700 | 1,120 | 1,670 |
M4 | FT-R43 | 750 | 1,250 | 1,750 | 2,650 | 3,600(Note2) | |
FT-R41W | 800 | 1,300 | 1,850 | 2,900 | 3,600(Note2) | ||
FT-R42W | 2,800 | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | ||
FT-R44Y | 800 | 1,300 | 1,800 | 2,900 | 3,600(Note2) | ||
M6 | FT-R60Y | 1,900 | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) |
Note1:Note that sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
Note2:The fiber cable length practically limits the sensing range.
■Reflective type
Type | Model No. | Sensing range(mm) (Note1)(Note2) | |||||
---|---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | |||
Square head | M3 | FD-R31G | 160 | 290 | 400 | 600 | 900 |
FD-R32EG | 45 | 80 | 110 | 180 | 290 | ||
FD-R34EG | 40 | 70 | 90 | 140 | 250 | ||
FD-R33EG | 18 | 30 | 40 | 65 | 110 | ||
M4 | FD-R41 | 190 | 340 | 450 | 750 | 1,150 | |
M6 | FD-R61Y | 250 | 450 | 650 | 1,000 | 1,350 |
Note1:Note that sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
Note2:The sensing range is specified for white non-glossy paper.
For details of Square Head Fiber, refer to product information page.
>>Go to "Square Head Fiber"
Super Quality
■Thru-beam type (one pair set)
Type | Model No. | Sensing range(mm) | |||||
---|---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | |||
Threaded | M3 | FT-30 | 340 | 570 | 830 | 1,240 | 1,860 |
M4 | FT-40 | 960 | 1,570 | 2,200 | 3,100 | 3,600(Note1) | |
Cylindrical | ø1.5 | FT-S20 | 340 | 550 | 800 | 1,200 | 1,760 |
ø3 | FT-S30 | 1,000 | 1,650 | 2,250 | 3,100 | 3,600(Note1) |
Note:The fiber cable length practically limits the sensing range.
■Reflective type
Type | Model No. | Sensing range(mm) (Note1) | |||||
---|---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | |||
Threaded | M3 | FD-30 | 140 | 210 | 330 | 460 | 800 |
M4 | FD-40 | 140 | 210 | 330 | 460 | 800 | |
M6 | FD-60 | 420 | 750 | 970 | 1,300 | 1,750 | |
Cylindrical | ø3 | FD-S30 | 140 | 220 | 330 | 500 | 800 |
Note:The sensing range is specified for white non-glossy paper.
For details of Super Quality Fiber, refer to product information page.
>>Go to "Super Quality Fiber"
Threaded Type
■Thru-beam type (one pair set)
Type | Model No. | Sensing range(mm) (Note1) | ||||||
---|---|---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | ||||
Threaded | M3 | FT-31 | 290 | 480 | 700 | 1,000 | 1,580 | |
FT-31W | 250 | 420 | 580 | 890 | 1,300 | |||
FT-32 | 2,900 | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | |||
M4 | FT-43 | 1,400 | 2,200 | 3,100 | 3,600(Note2) | 3,600(Note2) | ||
FT-42 | 890 | 1,470 | 2,100 | 2,900 | 3,600(Note2) | |||
FT-42W | 710 | 1,200 | 1,780 | 2,600 | 3,600(Note2) | |||
FT-45X | 1,070 | 1,600(Note2) | 1,600(Note2) | 1,600(Note2) | 1,600(Note2) | |||
Elbow | FT-R40 | 860 | 1,400 | 1,950 | 2,900 | 3,600(Note2) | ||
M14 | Long range | FT-140 | 19,600(Note2) | 19,600(Note2) | 19,600(Note2) | 19,600(Note2) | 19,600(Note2) |
Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
Note 2:The fiber cable length practically limits the sensing range.
■Reflective type
Type | Model No. | Sensing range(mm) (Note1)(Note2) | ||||||
---|---|---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | ||||
Threaded | M3 | FD-31 | 140 | 200 | 310 | 450 | 750 | |
FD-31W | 80 | 130 | 190 | 310 | 480 | |||
FD-32G | 170 | 320 | 420 | 730 | 1,150 | |||
FD-32GX | 180 | 320 | 490 | 730 | 1,350 | |||
FD-34G | 80 | 130 | 180 | 310 | 480 | |||
Ultra-small diameter | FD-EG30 | 50 | 90 | 120 | 190 | 320 | ||
FD-EG31 | 20 | 35 | 45 | 70 | 120 | |||
M4 | FD-41 | 140 | 200 | 310 | 450 | 750 | ||
FD-41W | 270 | 480 | 680 | 1,000 | 1,400 | |||
FD-42G | 170 | 320 | 420 | 730 | 1,150 | |||
FD-42GW | 130 | 210 | 330 | 540 | 950 | |||
M6 | FD-62 | 550 | 880 | 1,140 | 1,450 | 1,950 | ||
FD-61 | 380 | 620 | 870 | 1,180 | 1,630 | |||
FD-61W | 270 | 480 | 680 | 1,000 | 1,400 | |||
FD-61G (Discontinued products) | 350 | 600 | 850 | 1,200 | 1,350 | |||
FD-64X | 230 | 410 | 590 | 700 | 1,200 | |||
Elbow | FD-R60 | 350 | 500 | 800 | 1,150 | 1,450 |
Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
Note 2:The sensing range is specified for white non-glossy paper.
For details of Threaded Type Fiber, refer to product information page.
>>Go to "Threaded Type Fiber"
Cylindrical Type
■Thru-beam type (one pair set)
Type | Model No. | Sensing range(mm) (Note1) | ||||||
---|---|---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | ||||
Cylindrical | ø1 | FT-S11 | 80 | 130 | 180 | 280 | 400 | |
ø1.5 | FT-S21 | 280 | 450 | 670 | 1,000 | 1,600 | ||
FT-S21W | 240 | 400 | 580 | 850 | 1,650 | |||
FT-S22 | 530 | 870 | 1,200 | 1,900 | 2,900 | |||
ø2.5 | FT-S32 | 3,000 | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | ||
ø3 | FT-S31W | 650 | 1,100 | 1,600 | 2,450 | 3,600(Note2) | ||
Ultra-small diameter | ø3 | FT-E13 | 12 | 21 | 30 | 45 | 68 | |
FT-E23 | 70 | 120 | 165 | 250 | 355 | |||
Side-view | ø4 | FT-V40 | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) |
Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
Note 2:The fiber cable length practically limits the sensing range.
■Reflective type
Type | Model No. | Sensing range(mm) (Note1)(Note2) | ||||||
---|---|---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | ||||
Cylindrical | ø1.5 | FD-S21 | 50 | 85 | 110 | 130 | 175 | |
ø3 | FD-S32 | 350 | 600 | 900 | 1,200 | 1,600 | ||
FD-S32W | 250 | 450 | 650 | 1,000 | 1,400 | |||
FD-S31 | 130 | 200 | 300 | 450 | 700 | |||
FD-S33GW | 150 | 240 | 370 | 550 | 880 | |||
FD-S34G | 80 | 130 | 180 | 310 | 480 | |||
Ultra-small diameter | ø1.5 | FD-E13 | 12 | 23 | 30 | 50 | 75 | |
ø3 | FD-E23 | 45 | 80 | 105 | 170 | 290 |
Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
Note 2:The sensing range is specified for white non-glossy paper.
For details of Cylindrical Type Fiber, refer to product information page.
>>Go to "Cylindrical Type Fiber"
Sleeve
■Thru-beam type (one pair set)
Type | Model No. | Sensing range(mm) (Note1) | ||||||
---|---|---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | ||||
Threaded | M3 | FT-31S | 290 | 480 | 700 | 1,000 | 1,580 | |
M4 | FT-42S | 890 | 1,470 | 2,100 | 2,900 | 3,600(Note2) | ||
Cylindrical | Ultra-small diameter | ø3 | FT-E13 | 12 | 21 | 30 | 45 | 68 |
FT-E23 | 70 | 120 | 165 | 250 | 355 | |||
Side-view | ø2 | FT-V23 | 450 | 750 | 1,050 | 1,600 | 2,400 | |
FT-V25 | 280 | 450 | 630 | 950 | 1,400 | |||
FT-V24W | 95 | 160 | 220 | 350 | 500 | |||
ø2.5 | FT-V30 | 550 | 950 | 1,300 | 1,950 | 3,600(Note2) |
Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
Note 2:The fiber cable length practically limits the sensing range.
■Reflective type
Type | Model No. | Sensing range(mm) (Note1)(Note2) | ||||||
---|---|---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | ||||
Threaded | Ultra-small diameter | M3 | FD-EG30S | 50 | 90 | 120 | 190 | 320 |
M4 | FD-41S | 140 | 200 | 310 | 450 | 750 | ||
FD-41SW | 80 | 130 | 190 | 310 | 480 | |||
M6 | FD-61S | 400 | 650 | 900 | 1,300 | 1,900 | ||
Cylindrical | Ultra-small diameter | ø1.5 | FD-E13 | 12 | 23 | 30 | 50 | 75 |
ø3 | FD-E23 | 45 | 80 | 105 | 170 | 290 | ||
Side-view | ø3 | FD-V30 | 65 | 90 | 145 | 210 | 430 | |
FD-V30W | 16 | 30 | 37 | 65 | 120 | |||
ø5 | FD-V50 | 110 | 180 | 240 | 400 | 530 |
Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
Note 2:The sensing range is specified for white non-glossy paper.
For details of Sleeve Fiber, refer to product information page.
>>Go to "Sleeve Fiber"
Flat Type
■Thru-beam type (one pair set)
Type | Model No. | Sensing range(mm) (Note1) | |||||
---|---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | |||
Flat | FT-Z30H | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | |
FT-Z30HW | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | ||
FT-Z30E | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | ||
FT-Z30EW | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | ||
FT-Z30 | 2,200 | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | ||
FT-Z30W | 1,700 | 2,800 | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | ||
With boss | FT-Z20W | 650 | 1,100 | 1,600(Note2) | 1,600(Note2) | 1,600(Note2) | |
FT-Z20HBW | 280 | 450 | 650 | 1,000 | 1,600(Note2) | ||
FT-Z40W | 1,200 | 2,000 | 2,800 | 3,600(Note2) | 3,600(Note2) | ||
FT-Z40HBW | 750 | 1,300 | 1,850 | 2,700 | 3,600(Note2) |
Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
Note 2:The fiber cable length practically limits the sensing range.
■Reflective type
Type | Model No. | Sensing range(mm) (Note1)(Note2) | |||||
---|---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | |||
Flat | With boss | FD-Z20W | 80 | 130 | 190 | 290 | 450 |
FD-Z20HBW | 100 | 170 | 240 | 370 | 550 | ||
FD-Z40W | 230 | 390 | 510 | 950 | 1,500 | ||
FD-Z40HBW | 270 | 480 | 680 | 1,000 | 1,350 |
Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
Note 2:The sensing range is specified for white non-glossy paper.
For details of Flat Type Fiber, refer to product information page.
>>Go to "Flat Type Fiber"
Narrow Beam
■Thru-beam type (one pair set)
Type | Model No. | Sensing range(mm) (Note1) | |||||
---|---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | |||
Narrow beam | FT-KS40 | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | |
Side view | FT-KV40 | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | |
FT-KV40W | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | ||
FT-KV26 | 650 | 1,100 | 1,600 | 2,300 | 3,600(Note2) | ||
FT-KV26H1 | 650 | 1,000 | 1,400 | 1,900 | 3,600(Note2) |
Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
Note 2:The fiber cable length practically limits the sensing range.
■Retroreflective type
Type | Model No. | Sensing range(mm) (Note1)(Note2) | |||||
---|---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | |||
With polarizing filters | FR-Z50HW | 100 to 950 | 100 to 1,150 | 100 to 1,400 | 100 to 1,800 | 100 to 2,250 | |
Wafer mapping | FR-KZ22E | 15 to 400 | 15 to 540 | 15 to 600 | 15 to 700 | 15 to 800 | |
Narrow beam | Top sensing | FR-KZ50H | 20 to 350 | 20 to 400 | 20 to 500 | 20 to 1,300 | 20 to 1,600 |
Side sensing | FR-KZ50E | 20 to 350 | 20 to 400 | 20 to 500 | 20 to 1,300 | 20 to 1,600 |
Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
Note 2:The sensing range is the possible setting range for the attached reflector. The fiber can detect an object less than setting range for the reflector.
■Reflective type
Type | Sensing range(mm) (Note1)(Note2) | |||||
---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | ||
Long range | FD-Z50HW | 10 to 590 | 10 to 950 | 10 to 1,300 | 10 to 2,100 | 10 to 3,700 |
Note:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
For details of Narrow Beam Fiber, refer to product information page.
>>Go to "Narrow Beam Fiber"
Wide Beam
■Thru-beam type (one pair set)
Type | Model No. | Sensing range(mm) (Note1) | ||||
---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | ||
Wide beam | FT-A32 | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) |
FT-A32W | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | |
FT-A11 | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | |
FT-A11W | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | |
Array | FT-AL05 | 660 | 1,150 | 1,600 | 2,350 | 3,600(Note2) |
Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
Note 2:The fiber cable length practically limits the sensing range to 3,600 mm long.
■Reflective type
Type | Model No. | Sensing range(mm) (Note1)(Note2) | ||||
---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | ||
Wide beam | FD-A16 | 250 | 350 | 350 | - | - |
Array | FD-AL11 | 320 | 450 | 700 | 1,000 | 1,300 |
Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
Note 2:The sensing range is specified for white non-glossy paper.
For details of Wide Beam Fiber, refer to product information page.
>>Go to "Wide Beam Fiber"
Convergent Reflective Type
■Reflective type
Type | Model No. | Sensing range(mm) (Note1)(Note2) | ||||
---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | ||
Glass substrate detection | FD-L32H | 0 to 50 | 0 to 65 | 0 to 75 | 0 to 90 | 0 to 100 |
FD-L30A | 0 to 46 | 0 to 52 | 0 to 62 | 0 to 68 | 0 to 72 | |
FD-L31A | 3 to 40 | 3 to 42 | 3 to 42 | 2 to 43 | 0 to 50 | |
FD-L22A | 0 to 32 | 0 to 34 | 0 to 35 | 0 to 35 | 0 to 35 | |
FD-L23 | 0 to 32 | 0 to 34 | 0 to 34 | 0 to 34 | 0 to 34 | |
FD-L11 | 0 to 12 | 0 to 13 | 0 to 13 | 0 to 13 | 0 to 14 | |
FD-L10 | 0 to 5 | 0 to 5 | 0 to 5.5 | 0 to 5.5 | 0 to 6 | |
FD-L21 | 2 to 18 | 1 to 19 | 1 to 19 | 1 to 20 | 1 to 20 | |
FD-L21W | 3 to 17 | 2 to 18 | 2 to 18 | 1 to 19 | 1 to 19 | |
General purpose | FD-L20H | 0 to 25 | 0 to 33 | 0 to 40 | 0 to 50 | 0 to 65 |
Ultla-small | FD-L12W | 0 to 10 | 0 to 12 | 0 to 15 | 0 to 16 | 0 to 17 |
Note 1:The sensing range is specified for transparent glass 100 x 100 x t0.7 mm (FD-L32H: R edge, FD-L21 and FD-L21W: t2 mm) (FD-L20H: white non-glossy paper, FD-L10: silicon wafers 100 x 100 mm).
Note 2:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
For details of Convergent Reflective Type Fiber, refer to product information page.
>>Go to "Convergent Reflective Type Fiber"
Retroreflective Type
■Retroreflective type
Type | Model No. | Sensing range(mm) (Note1)(Note2) | |||||
---|---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | |||
With polarizing filters | FR-Z50HW | 100 to 950 | 100 to 1,150 | 100 to 1,400 | 100 to 1,800 | 100 to 2,250 | |
Wafer mapping | FR-KZ22E | 15 to 400 | 15 to 540 | 15 to 600 | 15 to 700 | 15 to 800 | |
Narrow beam | Top sensing | FR-KZ50H | 20 to 350 | 20 to 400 | 20 to 500 | 20 to 1,300 | 20 to 1,600 |
Side sensing | FR-KZ50E | 20 to 350 | 20 to 400 | 20 to 500 | 20 to 1,300 | 20 to 1,600 |
Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
Note 2:The sensing range is the possible setting range for the attached reflector. The fiber can detect an object less than setting range for the reflector.
For details of Retroreflective Type Fiber, refer to product information page.
>>Go to "Retroreflective Type Fiber"
Chemical-resistant
■Thru-beam type (one pair set)
Type | Model No. | Sensing range(mm) (Note 1) | ||||
---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | ||
Chemical-resistant | FT-Z802Y | 3,600(Note 2) | 3,600(Note 2) | 3,600(Note 2) | 3,600(Note 2) | 3,600(Note 2) |
FT-HL80Y | 3,600(Note 2) | 3,600(Note 2) | 3,600(Note 2) | 3,600(Note 2) | 3,600(Note 2) | |
FT-L80Y | 3,600(Note 2) | 3,600(Note 2) | 3,600(Note 2) | 3,600(Note 2) | 3,600(Note 2) | |
FT-V80Y | 1,400 | 2,200 | 3,600(Note 2) | 3,600(Note 2) | 3,600(Note 2) |
Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
Note 2:The fiber cable length practically limits the sensing range.
■Reflective type
Type | Model No. | Sensing range(mm)(Note 1)(Note 2) | ||||
---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | ||
Chemical-resistant | FD-S60Y | 380 | 450 | 550 | 700 | - |
Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending on how the fiber is cut.
Note 2:The sensing range is specified for white non-glossy paper.
For details of Chemical-resistant Fiber, refer to product information page.
>>Go to "Chemical-resistant Fiber"
Heat-resistant
■Thru-beam type (one pair set)
Type | Heat-resistant temp. | Model No. | Sensing range(mm) (Note1) | ||||
---|---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | |||
Heat-resistant | 350℃ | FT-H35-M2 | 650 | 1,050 | 1,500 | 2,300 | 3,600(Note2) |
FT-H35-M2S6 | 650 | 1,050 | 1,500 | 2,300 | 3,600(Note2) | ||
200℃ | FT-H20W-M1 | 440 | 730 | 1,050 | 1,600(Note2) | 1,600(Note2) | |
FT-H20-M1 | 600 | 1,000 | 1,600(Note2) | 1,600(Note2) | 1,600(Note2) | ||
130℃ | FT-H13-FM2 | 750 | 1,150 | 1,690 | 2,700 | 3,600(Note2) | |
HHeat-resistant (joint) | 200℃ | FT-H20-J20-S | 530 | 860 | 1,200 | 1,800 | 2,600 |
FT-H20-J30-S | 530 | 860 | 1,200 | 1,800 | 2,600 | ||
FT-H20-J50-S | 530 | 860 | 1,200 | 1,800 | 2,600 | ||
FT-H20-VJ50-S | 620 | 1,000 | 1,400 | 2,200 | 3,600(Note2) | ||
FT-H20-VJ80-S | 620 | 1,000 | 1,400 | 2,200 | 3,600(Note2) |
Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
Note 2:The fiber cable length practically limits the sensing range.
■Reflective type
Type | Heat-resistant temp. | Model No. | Sensing range(mm) (Note1)(Note2) | |||||
---|---|---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | ||||
Heat-resistant | Threaded | 350℃ | FD-H35-M2 | 220 | 400 | 500 | 600 | 750 |
FD-H35-M2S6 | 220 | 400 | 500 | 600 | 750 | |||
FD-H35-20S | 230 | 410 | 550 | 750 | 850 | |||
200℃ | FD-H20-M1 | 300 | 450 | 650 | 1,000 | 1,350 | ||
FD-H20-21 | 250 | 450 | 650 | 850 | 1,250 | |||
130℃ | FD-H13-FM2 | 390 | 670 | 940 | 1,300 | 1,650 | ||
Glass substrate detection convergent reflective | 300℃ | FD-H30-L32 | 0 to 16 | 0 to 21 | 0 to 25 | 0 to 42 | 0 to 60 | |
250℃ | FD-H25-L43 | 1 to 26 | 1 to 28 | 1 to 29 | 1 to 30 | 1 to 31 | ||
FD-H25-L45 | 4 to 44 | 4 to 48 | 4 to 49 | 4 to 50 | 4 to 51 | |||
180℃ | FD-H18-L31 | 0 to 30 | 0 to 45 | 0 to 60 | 0 to 85 | 0 to 130 |
Note 1:The sensing range of reflective type is the value for white non-glossy paper (50 x 50 mm glass substrate for FD-H30-L32 and FD-H18-L31, transparent glass 100 x 100 x t0.7 mm for FD-H25-L43 and FD-H25-L45).
Note 2:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
For details of Heat-resistant Fiber, refer to product information page.
>>Go to "Heat-resistant Fiber"
One-Touch Connection System Vacuum-resistant Fibers
■Thru-beam type
Type | Model No. | Sensing range (mm)(Note 1) | |||||
---|---|---|---|---|---|---|---|
HYPR | U-LG | LONG | STD | FAST | |||
Vacuum- resistant | Thru-beam | FT-40V | 1,400 | 950 | 620 | 400 | 250 |
(Note 1):Atmospheric side fiber, FT-J9 (optional) is free-cut type.
Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
■Reflective type
Type | Model No. | Sensing range(mm) (Note 1)(Note 2) | |||||
---|---|---|---|---|---|---|---|
HYPR | U-LG | LONG | STD | FAST | |||
Vacuum- resistant | Long range reflective | FD-KZ50V | 5 to 1,500 | 10 to 1,000 | 15 to 650 | 20 to 450 | 20 to 300 |
Convergent reflective | FD-L10V | 0 to 27 | 0 to 19 | 0 to 13 | 0 to 11 | 0 to 7.5 |
(Note 1):The sensing range is the value for transparent glass 100 × 100 × t0.7 mm 3.937 × 3.937 × t0.028 in.
(Note 2):Atmospheric side fiber, FT-J9 (optional) is free-cut type.
Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
For details of One-Touch Connection System Vacuum-resistant Fibers, refer to product information page.
>>Go to "One-Touch Connection System Vacuum-resistant Fibers"
Vacuum-resistant
■Thru-beam type (one pair set)
Type | Model No. | Sensing range(mm) | |||||
---|---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | |||
Vacuum-resistant | Thru-beam | FT-H30-M1V-S | 250 | 400 | 620 | 950 | 1,400 |
■Reflective type
Type | Model No. | Sensing range(mm) (Note1) | |||||
---|---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | |||
Vacuum-resistant | Reflective | FD-H30-KZ1V-S | 20 to 300 | 20 to 450 | 15 to 650 | 10 to 1,000 | 5 to 1,500 |
Convergent reflective | FD-H30-L32V-S | 0 to 7.5 | 0 to 11 | 0 to 13 | 0 to 19 | 0 to 27 |
Note:The sensing range of reflective type is the value for transparent glass 100 x 100 x t0.7 mm.
For details of Vacuum-resistant Fiber, refer to product information page.
>>Go to "Vacuum-resistant Fiber"
------------------------------ Tab9 showing ------------------------------
Cautions For Use
- Never use this product as a sensing device for personnel protection.
- In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country.
Wiring
- Make sure that the power supply is OFF while adding or removing the amplifiers.
- Note that if a voltage exceeding the rated range is applied, or if an AC power supply is directly connected, the product may get burnt or damaged.
- Note that short-circuit of the load or wrong wiring may burn or damage the product.
- Do not run the wires together with high-voltage lines or power lines, or put them in the same raceway.
This can cause malfunction due to induction. - Verify that the supply voltage variation is within the rating.
- If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground.
- In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity of this product, connect the frame ground (F.G.) terminal of the equipment to an actual ground.
- Make sure to use the quick-connection cable (optional) for the connection of the controller.
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2 or more, cable.
However, in order to reduce noise, make the wiring as short as possible. - Make sure that stress by forcible bending or pulling is not applied to the sensor cable joint and fiber cable.
Others
- This product has been developed / produced for industrial use only.
- The specification may not be satisfied in a strong magnetic field.
- The ultra long distance (U-LG, HYPR) mode is more likely to be affected by extraneous noise since the sensitivity of that is higher than the other modes. Make sure to check the environment before use.
- Do not use during the initial transient time (H-SP, FAST, STD: 0.5 sec., LONG, U-LG, HYPR: 1 sec.) after the power supply is switched ON.
- These sensors are only for indoor use.
- Avoid dust, dirt, and steam.
- Make sure that the product does not come in contact with oil, grease, organic solvents such as thinner, etc., strong acid or alkaline.
- This product cannot be used in an environment containing inflammable or explosive gases.
- Never disassemble or modify this product.
- This product adopts EEPROM. Settings cannot be done a million times or more because of the EEPROM's lifetime.