Panasonic Industry / Automation Controls
Panasonic Industry / Automation Controls

Digital Fiber Sensor FX-500 Ver.2

  • Basic Information

  • Order guide

  • Option

  • Specifications

  • Dimensions

  • Circuit/ Wiring

  • Sensing characteristics

  • List of fibers

  • Cautions For Use

------------------------------ Tab1 showing ------------------------------

Basic Information

At the industry’s leading edge

UL/C-UL,CE,UKCA Approved

UL : Approved Listing

------------------------------ Tab2 showing ------------------------------

Order guide

Amplifiers

Quick-connection cable is not supplied with FX-501(P) and FX-502(P). Please order it separately.

TypeAppearanceModel No.Emitting
element
OutputExternal
input
Standard
type

FX-501Red LEDNPN open-collector transistor-
FX-501PPNP open-collector transistor
2-output
type
FX-502NPN open-collector transistor 2 outputsIncorporated
(Switchable with Output 2)
FX-502PPNP open-collector transistor 2 outputs
Cable
type

FX-505-C2NPN open-collector transistor 2 outputs analog outputIncorporated
FX-505P-C2PNP open-collector transistor 2 outputs analog output

Quick-connection cables for FX-501(P)

Quick-connection cable is not supplied with the amplifier. Please order it separately.

TypeModel No.Description
Main cable
(3-core)
CN-73-C1Length: 1 m 3.281 ft0.2 mm2 3-core cabtyre cable, with connector on one end
Cable outer diameter: ø3.3 mm ø0.130 in
CN-73-C2Length: 2 m 6.562 ft
CN-73-C5Length: 5 m 16.404 ft
Sub cable
(1-core)
CN-71-C1Length: 1 m 3.281 ft0.2 mm2 1-core cabtyre cable, with connector on one end
Cable outer diameter: ø3.3 mm ø0.130 in
CN-71-C2Length: 2 m 6.562 ft
CN-71-C5Length: 5 m 16.404 ft

(Note):

The material of Quick-connection cable will be changed from production in March 2013, as soon as the previous ones are shipped out.
・Conductor cross-sectional area has been changed from 0.15mm2 to 0.2mm2.
・Sheath diameter has been changed from ø3.0mm to ø3.3mm.

Main cable

CN-73-C□

Sub cable

CN-71-C□

Quick-connection cables for FX-502(P)

Quick-connection cable is not supplied with the amplifier. Please order it separately.

TypeModel No.Description
Main cable
(4-core)
CN-74-C1Length: 1 m 3.281 ft0.2 mm2 4-core cabtyre cable, with connector on one end
Cable outer diameter: ø3.3 mm ø0.130 in
CN-74-C2Length: 2 m 6.562 ft
CN-74-C5Length: 5 m 16.404 ft
Sub cable
(2-core)
CN-72-C1Length: 1 m 3.281 ft0.2 mm2 2-core cabtyre cable, with connector on one end
Cable outer diameter: ø3.3 mm ø0.130 in
CN-72-C2Length: 2 m 6.562 ft
CN-72-C5Length: 5 m 16.404 ft

(Note):

The material of Quick-connection cable will be changed from production in March 2013, as soon as the previous ones are shipped out.
・Conductor cross-sectional area has been changed from 0.15mm2 to 0.2mm2.
・Sheath diameter has been changed from ø3.0mm to ø3.3mm.

Main cable

CN-74-C□

Sub cable

CN-72-C□

End plates

End plates are not supplied with the amplifier. Please order them separately when the amplifiers are mounted in cascade.

AppearanceModel No.Description

MS-DIN-EWhen cascading multiple amplifiers, or when it moves depending on the way it is installed on a DIN rail, these end plates clamp amplifiers into place on both sides.
Make sure to use end plates when cascading multiple amplifiers together.
[2 pcs. per set]

------------------------------ Tab3 showing ------------------------------

Option

DesignationModel No.Description
Amplifier
mounting bracket
MS-DIN-2Mounting bracket for amplifier

Amplifier mounting bracket

MS-DIN-2

MS-DIN-2

Accessory

FX-MB1 (Amplifier protection seal) 10 sets of 2 communication window seals and 1 connector seal

FX-MB1

Others

Please refer to "Fiber Options" for details of fiber lenses and other options.

------------------------------ Tab4 showing ------------------------------

Specifications

TypeStandard type2-output typeCable type
(Analog output type)
Model
No.
NPN outputFX-501FX-502FX-505-C2
PNP outputFX-501PFX-502PFX-505P-C2
Applicable regulations and certificationsCE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), UL/c-UL Listing certification
Supply voltage12 to 24 V DC+10-15 % Ripple P-P 10 % or less
Power consumptionNormal operation: 960 mW or less (current consumption 40 mA or less at 24 V supply voltage, excluding analog output of cable type)
ECO mode: 680 mW or less (current consumption 28 mA or less at 24 V supply voltage, excluding analog output of cable type)
Output
(2-output type and cable type:
Output 1, Output 2)
<NPN output type>
NPN open-collector transistor
• Maximum sink current: 100 mA (2-output type and cable type are 50 mA) (Note 2)
• Applied voltage: 30 V DC or less (between output and 0 V)
• Residual voltage: 2 V or less (Note 3) (at maximum sink current)

<PNP output type>
PNP open-collector transistor
• Maximum source current: 100 mA (2-output type and cable type are 50 mA) (Note 2)
• Applied voltage: 30 V DC or less (between output and +V)
• Residual voltage: 2 V or less (Note 3) (at maximum source current)
 Output points1 point2 points
Output operationSwitchable either Light-ON or Dark-ON by L/D mode
Short-circuit protectionIncorporated
Response timeH-SP: 25 μs or less, FAST: 60 μs or less, STD: 250 μs or less, LONG: 2 ms or less, U-LG: 4 ms or less, HYPR: 24 ms or less, selectable
Analog output
(Cable type only)
Output current: 4 to 20 mA approx. [H-SP, FAST STD: At 0 to 4,000 digits, LONG: At 0 to 8,000 digits (Note 4)], Response time: 2 ms or less, Zero point: Within 4 mA ±1 % F.S., Span: Within 16 mA ±5 % F.S., Linearity: Within ±3 % F.S., Load resistance: 0 to 250 Ω
External input
(2-output type only, switchable
with Output 2)
-<NPN output type>
NPN non-contact input
• Signal condition
High: +8 V to +V DC or Open
Low: 0 to +1.2 V DC
(at 0.5 mA source current)
• Input impedance: 10 kΩ approx.

<PNP output type>
PNP non-contact input
• Signal condition
High: +4 V to +V DC (at 3 mA sink current)
Low: 0 to +0.6 V DC or Open
• Input impedance: 10 kΩ approx.
Possible external
input function
-Emission halt / Teaching (Full-auto, Limit, 2-point) / Logic operation setting / Copy lock / Display adjustment / Data bank load / Data bank save, selectable
Sensitivity setting2-point teaching / Limit teaching / Full-auto teaching / Manual adjustment
Incident light
intensity display range
H-SP / FAST / STD: 0 to 4,000, LONG: 0 to 8,000, U-LG / HYPR: 0 to 9,999
Timer functionIncorporated with variable OFF-delay / ON-delay /One-shot / ON OFF-delay / ON-delay • One-shot timer, switchable either effective or ineffective<Output 1>
Incorporated with variable OFF-delay / ON-delay /One-shot / ON OFF-delay / ON-delay • One-shot timer, switchable either effective or ineffective
<Output 2>
Incorporated with variable OFF-delay / ON-delay /One-shot timer, switchable either effective or ineffective
 Timer periodTimer range "ms": 0.5 ms approx., 1 to 9,999 ms approx., 1 ms approx.,
Timer range "sec.": 0.5 s approx., 1 to 32 s approx., 1 s approx.,
Timer range "1/10 ms": 0.05 ms approx., 0.1 to 999.9 ms approx., 0.1 ms approx., each output is set individually
Light emitting
amount selection
function
Incorporated, 3 levels (each level 25 to 100 %) + Auto setting [1 level (25 to 100 %) when using H-SP mode]
Interference
prevention function
Incorporated (Note 5), selectable either automatic interference prevention or different frequency
Various settingsHysteresis setting / Shift amount setting / Emission power setting / Display turning setting / ECO setting / Data bank loading saving setting / Copying setting / Code setting / Reset setting / Logical calculation setting / Threshold tracking setting, etc.
ProtectionIP40 (IEC)
Ambient
temperature
-10 to +55 ℃ +14 to +131
[If 4 to 7 units are mounted in cascade: -10 to +50 ℃ +14 to +122 or if 8 to 16 units (cable type: 8 to 12 units) are mounted in cascade: -10 to +45 ℃ +14 to +113 ]
(No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158
Vibration resistance10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (10 G max.) in X, Y and Z directions for two hours each
Shock resistance98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
Emitting element
(modulated)
Red LED (Peak emission wavelength: 643 nm 0.025 mil)
MaterialEnclosure, Case cover: Polycarbonate, Switch: Polyacetal
Cable-0.2 mm2 6-core cabtyre cable,
2 m 6.562 ft long
Cable extension-Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
(however, supply voltage 12 V DC)
WeightNet weight: 15 g approx., Gross weight: 70 g approx.Net weight: 60 g approx.,
Gross weight: 100 g approx.
AccessoryFX-MB1 (Amplifier protection seal): 1 set

Notes:

1)Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.

2)50 mA max. if 5 or more standard types are connected together. (25 mA in case of 2-output type and cable type)

3)In case of using the quick-connection cable (cable length 5 m 16.404 ft) (optional).

4)If display adjustment was conducted, it is not in this range.

5)Number of sensor heads which is possible to be mounted closely in auto interference prevention function depends on response time as shown in table below.
Number of sensor heads which is possible to be mounted closely in different frequency Interference prevention function is up to 3 units.

Number of sensor heads mountable closely (Unit: set)

Response timeH-SPFASTSTDLONGU-LGHYPR
IP-10248812

------------------------------ Tab5 showing ------------------------------

Dimensions

  • Unit: mm in

FX-501(P)
FX-502(P)

Amplifier

FX-501(P) FX-502(P)

Notes:1) FX-502(P) only2) FX-501(P): Operation indicator3) FX-501(P): 3-pin, FX-502(P): 4-pin*The shape of setting switch will be changed from production at November, 2011. Please see drawing below.

Before the modification

FX-501(P) FX-502(P)

Notes:1) FX-502(P) only2) FX-501(P): Operation indicator3) FX-501(P): 3-pin, FX-502(P): 4-pin

FX-505-C2
FX-505P-C2

Amplifier

FX-505(P)-C2

Note: The shape of setting switch and cable will be changed from production at November, 2011. Please see drawing below.

Before the modification

CN-73-C□
CN-74-C□

Main cable (Optional)

CN-73-C CN-74-C□

Notes:1) CN-74-C□ only2) CN-73-C□: 3-core

• Length L

Model No.sample
CN-73/74-C11,000 39.370
CN-73/74-C22,000 78.740
CN-73/74-C55,000 196.850

CN-71-C□
CN-72-C□

Sub cable (Optional)

CN-71-C CN-72-C□

Notes:1) CN-72-C□ only2) CN-71-C□: 1-core

• Length L

Model No.sample
CN-71/72-C11,000 39.370
CN-71/72-C22,000 78.740
CN-71/72-C55,000 196.850

MS-DIN-2

Amplifier mounting bracket (Optional)

MS-DIN-2

Material: Cold rolled carbon steel (SPCC) (Uni-chrome plated)

MS-DIN-E

End plate (Optional)

MS-DIN-E

Material: Polycarbonate

FT-30

Super quality fibers・Thru-beam type

<with FX-AT2>

FT-30

FT-40

Super quality fibers・Thru-beam type

<with FX-AT2>

FT-40

FT-S20

Super quality fibers・Thru-beam type

<with FX-AT2>

FT-S20

FT-S30

Super quality fibers・Thru-beam type

<with FX-AT2>

FT-S30

FD-30

Super quality fibers・Reflective type

<with FX-AT2>

FD-30

FD-40

Super quality fibers・Reflective type

<with FX-AT2>

FD-40

FD-60

Super quality fibers・Reflective type

<with FX-AT2>

FD-60

FD-S30

Super quality fibers・Reflective type

<with FX-AT2>

FD-S30

------------------------------ Tab6 showing ------------------------------

I/O Circuit and Wiring diagrams

FX-501

NPN output type

I/O circuit diagram

NPN output type FX-501 I/O circuit diagram

Notes:

1)The quick-connection sub cable does not have +V (brown) and 0 V (blue). The power is supplied from the connector of the main cable.

2)50 mA max., if five amplifiers or more, are connected together.

Wiring diagram

NPN output type FX-501 Wiring diagram

Note:

The quick-connection sub cable does not have a brown and a blue lead wire.

Terminal arrangement diagram

NPN output type FX-501 Terminal arrangement diagram

FX-501P

PNP output type

I/O circuit diagram

PNP output type FX-501P I/O circuit diagram

Notes:

1)The quick-connection sub cable does not have +V (brown) and 0 V (blue). The power is supplied from the connector of the main cable.

2)50 mA max., if five amplifiers or more, are connected together.

Wiring diagram

PNP output type FX-501P Wiring diagram

Note:The quick-connection sub cable does not have a brown and a blue lead wire.

Terminal arrangement diagram

PNP output type FX-501P Terminal arrangement diagram

FX-502

NPN output type

I/O circuit diagram

NPN output type FX-502 I/O circuit diagram

Notes:

1)The quick-connection sub cable does not have +V (brown) and 0 V (blue). The power is supplied from the connector of the main cable.

2)25 mA max., if five amplifiers or more, are connected together.

Wiring diagram

NPN output type FX-502 Wiring diagram

Note:The quick-connection sub cable does not have a brown and a blue lead wire.

Terminal arrangement diagram

NPN output type FX-502 Terminal arrangement diagram

FX-502P

PNP output type

I/O circuit diagram

PNP output type FX-502P I/O circuit diagram

Notes:

1)The quick-connection sub cable does not have +V (brown) and 0 V (blue). The power is supplied from the connector of the main cable.

2)25 mA max., if five amplifiers or more, are connected together.

Wiring diagram

PNP output type FX-502P Wiring diagram

Note:The quick-connection sub cable does not have a brown and a blue lead wire.

Terminal arrangement diagram

PNP output type FX-502P Terminal arrangement diagram

FX-505-C2

NPN output type

I/O circuit diagram

PNP output type FX-505-C2 I/O circuit diagram

Wiring diagram

PNP output type FX-505-C2 Wiring diagram

FX-505P-C2

PNP output type

I/O circuit diagram

PNP output type FX-505P-C2 I/O circuit diagram

Wiring diagram

PNP output type FX-505P-C2 Wiring diagram

------------------------------ Tab7 showing ------------------------------

Sensing characteristics

*Other sensing characteristics can be downloaded at catalog download site.
>>Catalog Download site

FT-140

Thru-beam type
Parallel deviation

FT-140

FT-30

Thru-beam type
Parallel deviation

FT-30

FT-31

Thru-beam type
Parallel deviation

FT-31

FT-40

Thru-beam type
Parallel deviation

FT-40

FT-42

Thru-beam type
Parallel deviation

FT-42

FT-43

Thru-beam type
Parallel deviation

FT-43

FD-30

Reflective type
Sensing field

Horizontal direction

FD-30

Vertical direction

FD-30

FD-31

Reflective type
Sensing field

Horizontal direction

FD-31

Vertical direction

FD-31

FD-40

Reflective type
Sensing field

Horizontal direction

FD-40

Vertical direction

FD-40

FD-41

Reflective type
Sensing field

Horizontal direction

FD-41

Vertical direction

FD-41

FD-60

Reflective type
Sensing field

Horizontal direction

FD-60

Vertical direction

FD-60

FD-61

Reflective type
Sensing field

Horizontal direction

FD-61

Vertical direction

FD-61

FD-62

Reflective type
Sensing field

Horizontal direction

FD-62

Vertical direction

FD-62

------------------------------ Tab8 showing ------------------------------

List of fibers

Response time of FX-500 series.

ModeHYPRU-LGLONGSTDFASTH-SP
Response time24ms or less4ms or less2ms or less250μs or less60μs or less25μs or less

List of fiber

Square Head Fiber

■Thru-beam type(one pair set)

TypeModel
No.
Sensing range(mm) (Note1)
HYPRU-LGLONGSTDFASTH-SP
Square headM3FT-R311,00058044027016055
M4FT-R433,0001,6001,100720430130
FT-R41W3,2001,8001,400800460150
FT-R42W3,600 (Note2)3,600 (Note2)3,5002,2001,300460
FT-R44Y3,0001,6001,100720430130
M6FT-R60Y3,600 (Note2)3,600 (Note2)3,600 (Note2)2,1001,260400

Note1:Note that sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note2:The fiber cable length practically limits the sensing range.

■Reflective type

TypeModel
No.
Sensing range(mm) (Note1) (Note2)
HYPRU-LGLONGSTDFASTH-SP
Square headM3FD-R31G5303102601708527
FD-R32EG1701109245309
FD-R34EG130907038237
FD-R33EG84443319113
M4FD-R4171043032021010034
M6FD-R61Y99061043528016050

Note1:Note that sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note2:The sensing range is specified for white non-glossy paper.

For details of Square Head Fiber, refer to product information page.
>>Go to "Square Head Fiber"

Super Quality

■Thru-beam type (one pair set)

TypeModel No.Sensing range (mm)
HYPRU-LGLONGSTDFASTH-SP
ThreadedM3FT-301,35081065040021075
M4FT-403,600 (Note)2,2001,7001,200530190
Cylindricalφ1.5FT-S201,35081065040021075
φ3FT-S303,600 (Note)2,2001,7001,200530190

Note:The fiber cable length practically limits the sensing range.

■Reflective type

TypeModel No.Sensing range (mm) (Note)
HYPRU-LGLONGSTDFASTH-SP
ThreadedM3FD-306003302501608025
M4FD-406003302501608025
M6FD-601,55090074052026090
Cylindricalφ3FD-S306003302501608025

Note:The sensing range is specified for white non-glossy paper.

For details of Super Quality Fiber, refer to product information page.
>>Go to "Super Quality Fiber"

Threaded Type

■Thru-beam type (one pair set)

TypeModel No.Sensing range (mm) (Note 1)
HYPRU-LGLONGSTDFASTH-SP
ThreadedM3FT-311,35077055031521070
FT-31W99059044026015053
FT-323,600
(Note 2)
3,600
(Note 2)
3,600
(Note 2)
3,0001,600580
M4 FT-433,600
(Note 2)
2,8002,1001,400770240
FT-423,600
(Note 2)
2,0501,6001,130530190
FT-42W3,3001,9001,400800490160
FT-45X1,600
(Note 2)
1,600
(Note 2)
1,600
(Note 2)
1,200630200
ElbowFT-R403,600
(Note 2)
1,7501,500930500160
M14Long rangeFT-14019,600
(Note 2)
19,600
(Note 2)
19,600
(Note 2)
19,600
(Note 2)
16,0006,300

Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note 2:The fiber cable length practically limits the sensing range.

■Reflective type

TypeModel No.Sensing range (mm) (Note 1, 2)
HYPRU-LGLONGSTDFASTH-SP
ThreadedM3 FD-315152902201258025
FD-31W330180140804512
FD-32G6503802702009527
FD-32GX63041036020010030
FD-34G330185135904915
Ultra-small diameterFD-EG3017013011048309
FD-EG3185453520123.5
M4FD-415152902201258025
FD-41W90063043027015045
FD-42G6503802702009527
FD-42GW6703402801509025
M6 FD-621,5001,000940520340110
FD-611,40084067045020070
FD-61W90063043027015045
FD-61G1,10080065042020060
FD-64X67050041028016050
ElbowFD-R601,10060055029019065

Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note 2:The sensing range is specified for white non-glossy paper.

For details of Threaded Type Fiber, refer to product information page.
>>Go to "Threaded Type Fiber"

Cylindrical Type

■Thru-beam type (one pair set)

TypeModel No.Sensing range (mm) (Note 1)
HYPRU-LGLONGSTDFASTH-SP
Cylindricalφ1FT-S11350210160906019
φ1.5FT-S211,35077055031521070
FT-S21W99059044026015053
FT-S221,50092073045025090
φ2.5FT-S323,600 (Note 2)3,600 (Note 2)3,600 (Note 2)3,1001,800600
φ3FT-S31W3,3001,9001,400800490160
Ultra-small diameterφ3FT-E135230241582
FT-E23270160125754213
Side-viewφ4FT-V403,600 (Note 2)3,600 (Note 2)3,600 (Note 2)3,5002,400850

Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note 2:The fiber cable length practically limits the sensing range.

■Reflective type

TypeModel No.Sensing range (mm) (Note 1, 2)
HYPRU-LGLONGSTDFASTH-SP
Cylindricalφ1.5FD-S21190130110803711
φ3FD-S32120079066042022075
FD-S32W90063043027015045
FD-S315152902201258025
FD-S33GW6703402801509025
FD-S34G330185135904915
Ultra-small diameterφ1.5FD-E135029251272
φ3FD-E231701208055309

Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note 2:The sensing range is specified for white non-glossy paper.

For details of Cylindrical Type Fiber, refer to product information page.
>>Go to "Cylindrical Type Fiber"

Sleeve

■Thru-beam type (one pair set)

TypeModel No.Sensing range (mm) (Note 1, 2)
HYPRU-LGLONGSTDFASTH-SP
ThreadedM3FT-31S1,22074055031519563
M4FT-42S3,600 (Note 2)2,0501,6001,130530190
CylindricalUltra-small diameterφ3FT-E135230241582
FT-E23270160125754213
Side-viewφ2FT-V231,8001,00088045028090
FT-V2590055048024014045
FT-V24W3802302001106020
φ2.5FT-V302,2001,2001,000680340100

Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note 2:The fiber cable length practically limits the sensing range.

■Reflective type

TypeModel No.Sensing range (mm) (Note 1, 2)
HYPRU-LGLONGSTDFASTH-SP
ThreadedUltra-small diameterM3FD-EG30S1701108050309
M4FD-41S5152902201258025
FD-41SW330180140804512
M6FD-61S1,20079066042022075
CylindricalUltra-small diameterφ1.5FD-E135029251272
φ3FD-E231701208055309
Side-viewφ3FD-V30240130120653514
FD-V30W80403020102
φ5FD-V503702202101207525

Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note 2:The sensing range is specified for white non-glossy paper.

For details of Sleeve Fiber, refer to product information page.
>>Go to "Sleeve Fiber"

Flat Type

■Thru-beam type (one pair set)

TypeModel No.Sensing range (mm) (Note 1)
HYPRU-LGLONGSTDFASTH-SP
Flat FT-Z30H3,600 (Note 2)3,600 (Note 2)3,600 (Note 2)3,5002,600810
FT-Z30HW3,600 (Note 2)3,600 (Note 2)3,600 (Note 2)3,5002,600810
FT-Z30E3,600 (Note 2)3,600 (Note 2)3,600 (Note 2)3,5002,400740
FT-Z30EW3,600 (Note 2)3,600 (Note 2)3,600 (Note 2)3,4002,000630
FT-Z303,600 (Note 2)3,600 (Note 2)3,600 (Note 2)2,1001,200410
FT-Z30W3,600 (Note 2)3,3003,2001,5001,000280
With bossFT-Z20W1,600 (Note 2)1,5001,100620420130
FT-Z20HBW1,10067057026018055
FT-Z40W3,600 (Note 2)3,3002,3001,500900290
FT-Z40HBW3,3001,9001,400800490160

Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note 2:The fiber cable length practically limits the sensing range.

■Reflective type

TypeModel No.Sensing range (mm) (Note 1, 2)
HYPRU-LGLONGSTDFASTH-SP
FlatWith bossFD-Z20W2601501301 to 652 to 455 to 13
FD-Z20HBW1 to 3401 to 2101 to 1802 to 852 to 553 to 15
FD-Z40W7904403901901 to 1202 to 35
FD-Z40HBW7605404702601 to 1602 to 50

Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note 2:The sensing range is specified for white non-glossy paper.

For details of Flat Type Fiber, refer to product information page.
>>Go to "Flat Type Fiber"

Narrow Beam

■Thru-beam type (one pair set)

TypeModel No.Sensing range (mm) (Note 1)
HYPRU-LGLONGSTDFASTH-SP
Narrow beamFT-KS403,600 (Note 2)3,600 (Note 2)3,600 (Note 2)3,600 (Note 2)3,600 (Note 2)1,200
FT-KV403,600 (Note 2)3,600 (Note 2)3,600 (Note 2)3,600 (Note 2)3,100940
FT-KV40W3,600 (Note 2)3,600 (Note 2)3,600 (Note 2)3,600 (Note 2)3,100940
FT-KV262,5001,6001,200710440160
FT-KV26H12,2001,4301,070630390135

Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note 2:The fiber cable length practically limits the sensing range.

■Retroreflective type

TypeModel No.Sensing range (mm) (Note 1, 2)
HYPRU-LGLONGSTDFASTH-SP
With polarizing filtersFR-Z50HW100 to 1,900100 to 1,400100 to 1,200100-990100 to 780100 to 490
Wafer mappingFR-KZ22E15 to 57015 to 46015 to 41015 to 31015 to 22015 to 100
Narrow beamTop sensingFR-KZ50H20 to 1,00020 to 80020 to 40020 to 30020 to 20020 to 200
Side sensingFR-KZ50E20 to 1,00020 to 80020 to 40020 to 30020 to 20020 to 200

Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note 2:The sensing range is the possible setting range for the attached reflector. The fiber can detect an object less than setting range for the reflector.

■Reflective type

TypeModel No.Sensing range (mm) (Note)
HYPRU-LGLONGSTDFASTH-SP
Long rangeFD-Z50HW10 to 2,50010 to 1,10010 to 1,00010 to 65010 to 41015 to 130

Note:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

For details of Narrow Beam Fiber, refer to product information page.
>>Go to "Narrow Beam Fiber"

Wide Beam

■Thru-beam type (one pair set)

TypeModel No.Sensing range (mm) (Note 1)
HYPRU-LGLONGSTDFASTH-SP
Wide beamFT-A323,600 (Note 2)3,600 (Note 2)3,600 (Note 2)3,600 (Note 2)3,600 (Note 2)2,100
FT-A32W3,600 (Note 2)3,600 (Note 2)3,600 (Note 2)3,600 (Note 2)3,600 (Note 2)3,000
FT-A113,600 (Note 2)3,600 (Note 2)3,600 (Note 2)3,600 (Note 2)3,600 (Note 2)1,100
FT-A11W3,600 (Note 2)3,600 (Note 2)3,600 (Note 2)3,600 (Note 2)3,600 (Note 2)1,300
ArrayFT-AL052,3001,5501,500860500170

Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note 2:The fiber cable length practically limits the sensing range to 3,600 mm long.

■Reflective type

TypeModel No.Sensing range (mm) (Note 1, 2)
HYPRU-LGLONGSTDFASTH-SP
Wide beamFD-A16-20020020014075
ArrayFD-AL1167053051032018050

Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note 2:The sensing range is specified for white non-glossy paper.

For details of Wide Beam Fiber, refer to product information page.
>>Go to "Wide Beam Fiber"

Convergent Reflective Type

■Reflective type

TypeModel No.Sensing range (mm) (Note 1, 2)
HYPRU-LGLONGSTDFASTH-SP
Glass substrate detectionFD-L32H0 to 1100 to 870 to 740 to 561 to 38-
FD-L30A0 to 430 to 430 to 430 to 430 to 420 to 29
FD-L31A3 to 354 to 334 to 334 to 334 to 325 to 25
FD-L22A0 to 310 to 280 to 270 to 240 to 240 to 18
FD-L230 to 300 to 300 to 300 to 290 to 281.5 to 24
FD-L110 to 11.50 to 10.50 to 100 to 9.50 to 90 to 8
FD-L100 to 60 to 5.50 to 5.50 to 50 to 4.50 to 4
FD-L211 to 191 to 181 to 181.5 to 162 to 153 to 12
FD-L21W1.5 to 152 to 152 to 153 to 144 to 146.5 to 10
General purposeFD-L20H0 to 450 to 350 to 320 to 232 to 155 to 9
Ultla-smallFD-L12W0 to 140 to 12.50 to 120 to 80.5 to 70.5 to 4

Note 1:The sensing range is specified for transparent glass 100 x 100 x t0.7 mm (FD-L32H: R edge, FD-L21 and FD-L21W: t2 mm) (FD-L20H: white non-glossy paper, FD-L10: silicon wafers 100 x 100 mm).

Note 2:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

For details of Convergent Reflective Type Fiber, refer to product information page.
>>Go to "Convergent Reflective Type Fiber"

Retroreflective Type

■Retroreflective type

TypeModel No.Sensing range (mm) (Note 1, 2)
HYPRU-LGLONGSTDFASTH-SP
With polarizing filtersFR-Z50HW100 to 1,900100 to 1,400100 to 1,200100 to 990100 to 780100 to 490
Wafer mappingFR-KZ22E15 to 57015 to 46015 to 41015 to 31015 to 22015 to 100
Narrow beamTop sensingFR-KZ50H20 to 1,00020 to 80020 to 40020 to 30020 to 20020 to 200
Side sensingFR-KZ50E20 to 1,00020 to 80020 to 40020 to 30020 to 20020 to 200

Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note 2:The sensing range is the possible setting range for the attached reflector. The fiber can detect an object less than setting range for the reflector.

For details of Retroreflective Type Fiber, refer to product information page.
>>Go to "Retroreflective Type Fiber"

Chemical-resistant

■Thru-beam type (one pair set)

TypeModel No.Sensing range (mm) (Note 1)
HYPRU-LGLONGSTDFASTH-SP
Chemical-resistantFT-Z802Y3,600 (Note 2)3,600 (Note 2)3,600 (Note 2)3,1001,900470
FT-HL80Y3,600 (Note 2)3,600 (Note 2)3,600 (Note 2)3,600 (Note 2)2,300740
FT-L80Y3,600 (Note 2)3,600 (Note 2)3,600 (Note 2)3,600 (Note 2)2,800920
FT-V80Y3,600 (Note 2)2,8002,2001,300800240

Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note 2:The fiber cable length practically limits the sensing range.

■Reflective type

TypeModel No.Sensing range (mm) (Note1)(Note2)
HYPRU-LGLONGSTDFAST

H-SP

Chemical-resistantFD-S60Y60059042032020075

Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending on how the fiber is cut.

Note 2:The sensing range is specified for white non-glossy paper.

For details of Chemical-resistant Fiber, refer to product information page.
>>Go to "Chemical-resistant Fiber"

Heat-resistant

■Thru-beam type (one pair set)

TypeHeat-resistant
temp.
Model No.Sensing range (mm) (Note 1)
HYPRU-LGLONGSTDFASTH-SP
Heat-resistant350℃FT-H35-M21,20088067043025080
FT-H35-M2S61,20088067043025080
200℃FT-H20W-M11,600 (Note 2)1,00084047030090
FT-H20-M11,600 (Note 2)1,300960540330110
130℃FT-H13-FM23,3001,9001,300700410140
Heat-resistant (joint)200℃FT-H20-J20-S1,6001,00079047030090
FT-H20-J30-S1,6001,00079047030090
FT-H20-J50-S1,6001,00079047030090
FT-H20-VJ50-S2,1001,300980600390120
FT-H20-VJ80-S2,1001,300980600390120

Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note 2:The fiber cable length practically limits the sensing range.

■Reflective type

TypeHeat-resistant
temp.
Model No.Sensing range (mm) (Note 1, 2)
HYPRU-LGLONGSTDFASTH-SP
Heat-resistantThreaded350℃FD-H35-M272054046026015045
FD-H35-M2S672054046026015045
FD-H35-20S84055044026014045
200℃FD-H20-M184055050033020055
FD-H20-2177050038023013045
130℃FD-H13-FM288064060035020065
Glass substrate detection convergent reflective300℃FD-H30-L320 to 400 to 300 to 250 to 170 to 121.5 to 6
250℃FD-H25-L431 to 311 to 301 to 281.5 to 261.5 to 242 to 18
FD-H25-L454 to 43.54 to 434.5 to 435 to 425 to 406.5 to 34
180℃FD-H18-L310 to 600 to 320 to 240 to 160 to 132 to 6.5

Note 1:The sensing range of reflective type is the value for white non-glossy paper (50 x 50 mm glass substrate for FD-H30-L32 and FD-H18-L31, transparent glass 100 x 100 x t0.7 mm for FD-H25-L43 and FD-H25-L45).

Note 2:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

For details of Heat-resistant Fiber, refer to product information page.
>>Go to "Heat-resistant Fiber"

One-Touch Connection System Vacuum-resistant Fibers NEW

■Thru-beam type

TypeModel No.Sensing range (mm)(Note 1)
HYPRU-LGLONGSTDFASTH-SP
Vacuum-
resistant
Thru-beamFT-40V1,00059047027016055

(Note 1):Atmospheric side fiber, FT-J9 (optional) is free-cut type.
Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

■Reflective type

TypeModel No.Sensing range(mm) (Note 1)(Note 2)
HYPRU-LGLONGSTDFASTH-SP
Vacuum-
resistant
Long range
reflective
FD-KZ50V5 to 50010 to 34015 to 27020 to 20020 to 12020 to 45
Convergent
reflective
FD-L10V0 to 180 to 120 to 100 to 80 to 5.51.5 to 3

(Note 1):The sensing range is the value for transparent glass 100 × 100 × t0.7 mm 3.937 × 3.937 × t0.028 in.

(Note 2):Atmospheric side fiber, FT-J9 (optional) is free-cut type.
Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

For details of One-Touch Connection System Vacuum-resistant Fibers, refer to product information page.
>>Go to "One-Touch Connection System Vacuum-resistant Fibers"

Vacuum-resistant

■Thru-beam type (one pair set)

TypeModel No.Sensing range (mm)
HYPRU-LGLONGSTDFASTH-SP
Vacuum-resistantThru-beamFT-H30-M1V-S1,00059047027016055

■Reflective type

TypeModel No.Sensing range (mm) (Note)
HYPRU-LGLONGSTDFASTH-SP
Vacuum-resistantReflectiveFD-H30-KZ1V-S5 to 50010 to 34015 to 27020 to 20020 to 12020 to 45
Convergent reflectiveFD-H30-L32V-S0 to 180 to 120 to 100 to 80 to 5.51.5 to 3

Note:The sensing range of reflective type is the value for transparent glass 100 x 100 x t0.7 mm.

For details of Vacuum-resistant Fiber, refer to product information page.
>>Go to "Vacuum-resistant Fiber"

Discontinued products

Metal-free

■Thru-beam type (one pair set)

TypeModel No.Sensing range (mm) (Note)
HYPRU-LGLONGSTDFASTH-SP
ThreadedM4FT-413,3002,0001,5501,100445150

Note:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

■Reflective type

TypeModel No.Sensing range (mm) (Note 1, 2)
HYPRU-LGLONGSTDFASTH-SP
ThreadedM4FD-G405503302701408027
M6FD-G601,40080065042020060

Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

Note 2:The sensing range is specified for white non-glossy paper.

For details of Metal-free Fiber, refer to product information page.
>>Go to "Metal-free Fiber"

------------------------------ Tab9 showing ------------------------------

Cautions For Use

  • Never use this product as a sensing device for personnel protection.
  • In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country.

Wiring

  • Make sure that the power supply is OFF while adding or removing the amplifiers.
  • Note that if a voltage exceeding the rated range is applied, or if an AC power supply is directly connected, the product may get burnt or damaged.
  • Note that short-circuit of the load or wrong wiring may burn or damage the product.
  • Do not run the wires together with high-voltage lines or power lines, or put them in the same raceway.
    This can cause malfunction due to induction.
  • Verify that the supply voltage variation is within the rating.
  • If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground.
  • In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity of this product, connect the frame ground (F.G.) terminal of the equipment to an actual ground.
  • Make sure to use the quick-connection cable (optional) for the connection of the controller.
    Extension up to total 100 m 328.084 ft is possible with 0.3 mm2 or more, cable.
    However, in order to reduce noise, make the wiring as short as possible.
  • Make sure that stress by forcible bending or pulling is not applied to the sensor cable joint and fiber cable.
  • In case requiring conformity of UL listing mark or C-UL listing mark, use a class 2 power supply unit.

Others

  • This product has been developed / produced for industrial use only.
  • The specification may not be satisfied in a strong magnetic field.
  • The ultra long distance (U-LG, HYPR) mode is more likely to be affected by extraneous noise since the sensitivity of that is higher than the other modes. Make sure to check the environment before use.
  • Do not use during the initial transient time (H-SP, FAST, STD: 0.5 sec., LONG, U-LG, HYPR: 1 sec.) after the power supply is switched ON.
  • These sensors are only for indoor use.
  • Avoid dust, dirt, and steam.
  • Make sure that the product does not come in contact with oil, grease, organic solvents such as thinner, etc., strong acid or alkaline.
  • This product cannot be used in an environment containing inflammable or explosive gases.
  • Never disassemble or modify this product.
  • This product adopts EEPROM. Settings cannot be done a million times or more because of the EEPROM's lifetime.

MENU

Recently checked products

Recently checked product numbers