Panasonic Industry / Automation Controls
Panasonic Industry / Automation Controls

Manually Set Fiber Sensor FX-311

  • Basic Information

  • Applications

  • Order guide

  • Option

  • Specifications

  • Dimensions

  • Circuit/ Wiring

  • List of fibers

  • Cautions For Use

------------------------------ Tab1 showing ------------------------------

Basic Information

Highly sensitive manual tuning made easy

UL,CE,UKCA Approved

CE : EMC Directive
UL : Recognition

------------------------------ Tab2 showing ------------------------------

Applications

Detecting register marks

Detecting register marks

Detecting transparent bottles

Detecting transparent bottles

Sensing the presence of a translucent sheet

Sensing the presence of a translucent sheet

------------------------------ Tab3 showing ------------------------------

Order guide

Amplifiers

Quick-connection cable is not supplied with the amplifier. Please order it separately.



Manually set

TypeAppearanceModel No.Emitting elementOutput
NPN
output

FX-311Red LEDNPN open-collector
transistor
FX-311BBlue LED
FX-311GGreen LED
PNP
output
FX-311PRed LEDPNP open-collector
transistor
FX-311BPBlue LED
FX-311GPGreen LED

Quick-connection cables

Quick-connection cable is not supplied with the amplifier. Please order it separately.

TypeModel No.Description
Main cable
(3-core)
CN-73-C1Length: 1 m 3.281 ft0.2 mm2 3-core cabtyre cable, with connector on one end
Cable outer diameter: ø3.3 mm ø0.130 in
CN-73-C2Length: 2 m 6.562 ft
CN-73-C5Length: 5 m 16.404 ft
Sub cable
(1-core)
CN-71-C1Length: 1 m 3.281 ft0.2 mm2 1-core cabtyre cable, with connector on one end
Cable outer diameter: ø3.3 mm ø0.130 in
CN-71-C2Length: 2 m 6.562 ft
CN-71-C5Length: 5 m 16.404 ft

(Note):

The material of Quick-connection cable will be changed from production in March 2013, as soon as the previous ones are shipped out.
・Conductor cross-sectional area has been changed from 0.15mm2 to 0.2mm2.
・Sheath diameter has been changed from ø3.0mm to ø3.3mm.

Main cable

CN-73-C□

Sub cable

CN-71-C□

End plates

End plates are not supplied with the amplifier. Please order them separately when the amplifiers are mounted in cascade.

AppearanceModel No.Description

MS-DIN-EWhen amplifiers are mounted in cascade, or when an amplifier moves depending on the way it is installed on a DIN rail, these end plates clamp amplifiers into place on both sides. Make sure to use end plates when cascading multiple amplifiers together.
Two pcs. per set

------------------------------ Tab4 showing ------------------------------

Option

DesignationModel No.Description
Amplifier
mounting
bracket
MS-DIN-2Mounting bracket for amplifier
Fiber amplifier
protection seal
FX-MB110 sets of 2 communication window seals and 1 connector seal
Communication window seal:
It prevents malfunction due to transmission signal from another amplifier, as well as, prevents effect on another amplifier.
Connector seal:
It prevents contact of any metal, etc., with the pins of the quickconnection cable.

Amplifier mounting bracket

MS-DIN-2

Fiber amplifier protection seal

FX-MB1

------------------------------ Tab5 showing ------------------------------

Specifications

Amplifiers

TypeRed LEDBlue LEDGreen LED
Model No.NPN outputFX-311FX-311BFX-311G
PNP outputFX-311PFX-311BPFX-311GP
Supply voltage12 to 24 V DC ±10 % Ripple P-P 10 % or less
Power consumption840 mW or less (Current consumption 35 mA or less at 24 V supply voltage)
Output<NPN open-collector transistor>
• Maximum sink current: 100 mA
(50 mA, if five, or more, amplifiers are connected in cascade)
• Applied voltage: 30 V DC or less (between output and 0 V)
• Residual voltage: 1.5 V or less
[at 100 mA sink current (50 mA, if five, or more, amplifiers are connected in cascade)]

<PNP open-collector transistor>
• Maximum source current: 100 mA
(50 mA, if five, or more, amplifiers are connected in cascade)
• Applied voltage: 30 V DC or less (between output and +V)
• Residual voltage: 1.5 V or less
[at 100 mA sink current (50 mA, if five, or more, amplifiers are connected in cascade)]
 Utilization
category
DC-12 or DC-13
Output
operation
Selectable either Light-ON or Dark-ON, with selection switch
Short-circuit
protection
Incorporated
Response time<Red LED type>
250 μs or less (STD / S-D), 2 ms or less (LONG) selectable with selection switch

<Blue LED type / Green LED type>
150 μs or less (FAST), 250 μs or less (STD), 2 ms or less (LONG) selectable with selection switch
Operation indicatorOrange LED (lights up when the output is ON)
Stability indicatorGreen LED (lights up under stable light received condition or stable dark condition)
Sensitivity adjuster12-turn potentiometer with indicator (Pointer part: red backlight) (Note 2)
Timer functionIncorporated with OFF-delay timer, selectable either effective (approx. 10 ms or 40 ms) or ineffective
Automatic interference
prevention function
Incorporated (Up to 4 sets of fiber heads can be mounted close together.) (Note 3)
Pollution degree3 (Industrial environment)
Ambient temperature-10 to +55 ℃ -14 to +131 ℉
(If 4 to 7 units are connected in cascade: -10 to +50 ℃ +14 to +122 ℉,
if 8 to 16 units are connected in cascade: -10 to +45 ℃ +14 to +113 ℉)
(No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉
Ambient humidity35 to 85 % RH, Storage: 35 to 85 % RH
Ambient illuminanceIncandescent light: 3,000 ℓx at the light-receiving face
EMCEN 60947-5-2
Voltage withstandability1,000 V AC for one min. between all supply terminals connected together and enclosure (Note 4)
Insulation resistance20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure (Note 4)
Vibration resistance10 to 150 Hz frequency, 0.75 mm 0.03 in amplitude in X, Y and Z directions for two hours each
Shock resistance98 m/s2 acceleration (10 G approx.) in X, Y and Z directions for five times each
Emitting element
(modulated)
Red LEDBlue LEDGreen LED
 Peak emission
wavelength
650 nm
0.026 mil
470 nm
0.019 mil
525 nm
0.021 mil
MaterialEnclosure: Heat-resistant ABS, Case cover: Polycarbonate
Connecting methodConnector (Note 5)
Cable lengthTotal length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
WeightNet weight: 15 g approx., Gross weight: 20 g approx.

Notes:

1)Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.

2)The red backlight of the pointer part lights up more brightly when the power is turned ON and when the sensitivity is adjusted.

3)When the power supply is switched on, the emission timing are automatically set for interference prevention.

4)The voltage withstandability and the insulation resistance values given in the above table are for the amplifier only.

5)The cable for amplifier connection is not supplied as an accessory. Make sure to use the optional quick-connection cable given below.
Main cable (3-core): CN-73-C1 (cable length 1 m 3.281 ft), CN-73-C2 (cable length 2 m 6.562 ft), CN-73-C5 (cable length 5 m 16.404 ft)
Sub cable (1-core): CN-71-C1 (cable length 1 m 3.281 ft), CN-71-C2 (cable length 2 m 6.562 ft), CN-71-C5 (cable length 5 m 16.404 ft)

------------------------------ Tab6 showing ------------------------------

Dimensions

  • Unit: mm in

FX-311□
FX-311□P

Amplifier
Mounting drawing with a hand-turned knob attached cover FX-AJ1 (Optional)

FX-311□ FX-311□P

CN-73-C□

Main cable (Optional)

CN-73-C□


Length L

Model No.Length L
CN-73-C11,000
39.370
CN-73-C22,000
78.740
CN-73-C55,000
196.850

CN-71-C□

Sub cable (Optional)

CN-71-C□


Length L

Model No.Length L
CN-71-C11,000
39.370
CN-71-C22,000
78.740
CN-71-C55,000
196.850

MS-DIN-2

Amplifier mounting bracket (Optional)

MS-DIN-2

Material: Cold rolled carbon steel (SPCC) (Uni-chrome plated)

MS-DIN-E

End plate (Optional)

MS-DIN-E

Material: Polycarbonate

------------------------------ Tab7 showing ------------------------------

I/O Circuit and Wiring diagrams

FX-311□

NPN output type

I/O circuit diagram

I/O circuit diagram

Notes:1):The quick-connection sub cable does not have +V (brown) and 0 V (blue). The power is supplied from the connector of the main cable.2):50 mA max., if five amplifiers, or more, are connected together.

Wiring diagram

Wiring diagram

Note:The quick-connection sub cable does not have brown lead wire and blue lead wire. The power is supplied from the connector of the main cable.

Terminal arrangement diagram

Terminal arrangement diagram

FX-311□P

PNP output type

I/O circuit diagram

I/O circuit diagram

Notes:1):The quick-connection sub cable does not have +V (brown) and 0 V (blue). The power is supplied from the connector of the main cable.2):50 mA max., if five amplifiers, or more, are connected together.

Wiring diagram

Wiring diagram

Note:The quick-connection sub cable does not have brown lead wire and blue lead wire. The power is supplied from the connector of the main cable.

Terminal arrangement diagram

Terminal arrangement diagram

------------------------------ Tab8 showing ------------------------------

List of fibers

Response time of FX-311.

modeRed LED typeBlue LED / Green LED type
LONGSTDS-DLONGSTDFAST
Response time2ms or less250μs or less250μs or less2ms or less250μs or less150μs or less

Sensing range can be downloaded at the following.
Please contact our office if not listed here.

(Note) :The sensing ranges of following fibers have been changed from production in June, 2015.
Please note that the downloaded files have not been modified.

TypeOld (For production before May 2015)  New (For production after June 2015)
Sensing range (mm)Sensing range (mm)
Blue LEDGreen LEDBlue LEDGreen LED
U-LGSTDFASTU-LGSTDFASTU-LGSTDFASTU-LGSTDFAST
FT-Z301206040964530  3201501001608255
FT-Z30W834025733625250120801206041

------------------------------ Tab9 showing ------------------------------

Cautions For Use

  • Never use this product as a sensing device for personnel protection.
  • In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country.

Cautions For Use

  • Never use this product as a sensing device for personnel protection.
  • In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country.

Part description

Part description

Note: The mode selected by the mode selection switch for FX-311B(P) and FX-311G(P) is 'LONG', 'STD' or 'FAST'.

Amplifier of cascading

・Make sure that the power supply is off while adding or removing the amplifiers.

・Make sure to check the allowable ambient temperature, as it depends on the number of amplifiers connected in cascade.

・In case two, or more, amplifiers are connected in cascade, make sure to mount them on a DIN rail.

・When the amplifiers move on the DIN rail depending on the attaching condition, fitting them between the optional end plates (MS-DIN-E) mounted at the two ends.

・When connecting in cascade, mount the amplifiers close to each other, fitting them between the optional end plates (MS-DIN-E) mounted at the two ends.

・Up to maximum 15 amplifiers can be added (total 16 amplifiers connected in cascade.)

・When connecting more than two amplifiers in cascade, use the sub cable (CN-71-C□) as the quick-connection cable for the second amplifier onwards.

・The settings other than the interference prevention function cannot be transmitted between this product and other digital fiber amplifiers. Therefore, in case both models of amplifiers are mounted in cascade, be sure to mount identical models together.
For more details, refer to "Cautions on sensor connection in cascade".

Timer function

  • This product incorporates an OFF-delay timer function. The delay time can be selected as either 10 ms. approx. or 40 ms. approx. with the timer selection switch. Since the output is extended by a fixed period, it is useful when the connected device has a slow response time or when small objects are being sensed and the output signal width is small.

Note: The diagram shows the case when 10 ms delay time is selected.

Automatic interference prevention function

  • This product incorporates an automatic interference prevention function. If the amplifiers are mounted in cascade, since a different emission timing is automatically set for up to 4 amplifiers, up to 4 sets of fibers can be mounted closely.
    Further, even if the amplifiers are mounted closely along with the digital fiber sensor FX-300 series, the interference prevention function works. However, in case both models of amplifiers are mounted in cascade, mount identical models together.

Wiring

  • Make sure that the power supply is off while wiring.
  • Verify that the supply voltage variation is within the rating.
  • Take care that if a voltage exceeding the rated range is applied, or if an AC power supply is directly connected, the product may get burnt or damaged.
  • If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground.
  • In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity of this product, connect the frame ground (F.G.) terminal of the equipment to an actual ground.
  • Take care that short circuit of the load wrong wiring may burn or damage the product.
  • Do not run the wires together with high-voltage lines or power lines or put them in the same raceway. This can cause malfunction due to induction.
  • Make sure to use an isolation transformer for the DC power supply. If an autotransformer (single winding transformer) is used, this product or the power supply may get damaged.
  • Make sure to use the optional quick-connection cable for the connection of the amplifier. Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
    However, in order to reduce noise, make the wiring as short as possible.

Operation procedure

  • For FX-311(P), the most suitable sensing mode can be selected according to the application from LONG (long range distance), STD (standard) or S-D (reduced intensity). Furthermore, for FX-311B(P) and FX-311G(P), the sensing mode can be selected from LONG (long range distance), STD (standard) or FAST (high speed sensing).
Mode selection switchApplicationsResponse
time
FX-311(P)FX-311B(P)/311G(P)

Used in case long distance sensing is required.
(However, the response time is longer than in STD mode.)
2 ms

Used for general sensing application.250 μs
-

Used in case high speed sensing is required.150 μs

-Since the emitted light amount is restricted in this mode, it is suitable for delicate sensing, such as when the received light is saturated due to too short a sensing distance or when detecting translucent objects, etc.250 μs

Note:Make sure to carry out sensitivity adjustment after mode setting.

Sensitivity adjustment

Sensing
condition
OperationOperation
indicator
LightL-ON (Light-ON)Lights up
D-ON (Dark-ON)Turns off
DarkL-ON (Light-ON)Turns off
D-ON (Dark-ON)Lights up
  • Adjust the sensitivity, observing the operation indicator (orange).
    However, since the condition for lighting up of the indicator depends on the combination of the sensing condition and the selected operation of L/D-ON, verify it from the table below.
  • The sensitivity adjuster is a 12-turn potentiometer. The maximum sensitivity is obtained by turning it fully clockwise.
  • The pointer shows the present sensitivity level.

Assist function

Notes:

1)"Assist function" cannot be used when adjusting sensitivity for moving objects.

2)"Assist function" turns off automatically once the sensitivity adjustment has been completed.

3)In case "assist function" is not to be used, set the operation selection switch to D-ON (Dark ON) and wait for 2 sec., or more, to make "assist function" ineffective.

  • This product incorporates an "assist function", which helps to easily search the optimum sensitivity position by flashing of the pointer. In order to make "assist function" effective, switch the operation selection switch in the order L-ON (Light ON) → D-ON (Dark ON) → L-ON (Light ON).
StepSensing methodOperationSensitivity
indicator
Reflective typeThru-beam type
(1)Make sure that the operation selection switch is set to L-ON (Light ON).
In case "assist function" is to be used, switch the operation selection switch in the order of L-ON (Light ON) → D-ON (Dark ON) → L-ON (Light ON).
Turn the sensitivity adjuster fully counterclockwise.
(Minimum sensitivity)

(2)


Beam
received


Beam
received
In the beam received condition, slowly turn the adjuster clockwise and find the point (A) where the sensor is switched ON. The pointer flashes once at the point (A). (Note 1)

(3)


Beam not
received


Beam not
received
In the beam not received condition, slowly turn the adjuster further clockwise until the sensor goes into the ON state again. Once it is switched on, turn the adjuster counterclockwise a little and find the point (B) where it is switched OFF. The pointer flashes twice at the point (B). (Note 2)
(If the sensor does not go into the ON state, MAX is the point (B).)

(4)--Turn the adjuster towards the point (A) from the point (B) slowly. The pointer starts flashing when it approaches the optimum sensitivity point and flashes faster at the optimum sensitivity point for 3 sec. This point is the optimum sensitivity point. (Note 2)

(5)Select either L-ON (Light ON) or D-ON (Dark ON) according to your application.

Notes:

1)When "assist function" is not used, the pointer does not flash.

2)When "assist function" is not used, the middle point of (A) and (B) is regarded as the optimum sensitivity point.

3)In order to protect the mechanism, the sensitivity adjuster idles when over turned, which may result in a backlash of 1 to 2 divisions.

4)Depending upon the sensing conditions, stable sensing may be possible at a position which is slightly shifted from the optimum sensitivity point.

5)Do not move or bend the fiber cable after the sensitivity adjustment. Detection may become unstable.

Others

  • Do not use during the initial transient time (0.5 sec. approx.) after the power supply is switched on.
  • Take care that the sensor is not directly exposed to fluorescent lamp from a rapid-starter lamp, a high frequency lighting device or sunlight etc. , as it may affect the sensing performance.
  • This sensor is suitable for indoor use only.
  • Do not use this sensor in places having excessive vapor, dust, etc., or where it may come in contact with corrosive gas.
  • Take care that the sensor does not come in contact with water, oil, grease, organic solvents, such as, thinner etc., or strong acid, and alkaline.
  • This sensor cannot be used in an environment containing inflammable or explosive gases.
  • Never disassemble or modify the sensor.

MENU

Recently checked products

Recently checked product numbers