40 mm Beam Pitch General Purpose Area Sensor NA40 (Discontinued Products)
Download
-
Discontinued Products
-
Specifications
-
Dimensions
-
Circuit/ Wiring
-
Cautions For Use
Ⅾiscontinued
Last time buy (JST)
September 29, 2023
We are sorry, the products have been discontinued. Please refer to the details of the discontinued products and the recommended substitutes list below.
------------------------------ Tab1 showing ------------------------------
Discontinued Products
------------------------------ Tab2 showing ------------------------------
Specifications
Number of beam channels | 4 | 6 | 8 | 10 | 12 | |
---|---|---|---|---|---|---|
Model No. | NA40-4 | NA40-6 | NA40-8 | NA40-10 | NA40-12 | |
With spatter protection hood | NA40-4-H | NA40-6-H | NA40-8-H | NA40-10-H | NA40-12-H | |
Sensing height | 120 mm 4.724 in | 200 mm 7.874 in | 280 mm 11.024 in | 360 mm 14.173 in | 440 mm 17.323 in | |
Sensing range | 5 m 16.404 ft | |||||
Beam pitch | 40 mm 1.575 in | |||||
Sensing object | ø60 mm ø2.362 in or more opaque object | |||||
Supply voltage | 12 to 24 V DC ±10 % Ripple P-P 10 % or less | |||||
Current consumption | Emitter: 30 mA or less Receiver: 60 mA or less | Emitter: 35 mA or less, Receiver: 90 mA or less | ||||
Sensing output | NPN open-collector transistor • Maximum sink current: 100 mA • Applied voltage: 30 V DC or less (between sensing output and 0 V) • Residual voltage: 1.6 V or less (at 100 mA sink current) | |||||
Output operation | ON when all beam channels are received / OFF when one or more beam channels are interrupted | |||||
Short-circuit protection | Incorporated | |||||
Self-diagnosis output | NPN open-collector transistor • Maximum sink current: 50 mA • Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V) • Residual voltage: 1.6 V or less (at 50 mA sink current) | |||||
Output operation | OFF when unstable light received condition continues for 5 sec. or more, or the output transistor fails | |||||
Short-circuit protection | Incorporated | |||||
Response time | 12 ms or less | |||||
Indicator | Incorporated with the three color indicators on the receiver • Sensing output operation indicator: Red LED (lights up when one or more beam channels are interrupted) • Stable incident beam indicator: Green LED (lights up when all beam channels are received stably) • Unstable incident beam indicator: Yellow LED (lights up when one or more beam channels are received unstably) * When the output transistor fails, the three color indicators blink simultaneously. | |||||
Interference prevention function | Incorporated (Two units of sensors can be mounted close together.) | |||||
Protection | IP65 (IEC) | |||||
Ambient temperature | –10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage: –10 to +60 ℃ +14 to +140 ℉ | |||||
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | |||||
Ambient illuminance | Incandescent light: 3,500 ℓx or less at the light-receiving face | |||||
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure | |||||
Insulation resistance | 20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure | |||||
Vibration resistance | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | |||||
Shock resistance | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each | |||||
Emitting element | Infrared LED (synchronized scanning system) | |||||
Material | Protection enclosure: Aluminum, Unit case: ABS, Front cover: Acrylic, Lens: Acrylic | |||||
Cable | 0.5 mm2 4-core (emitter: 3-core) cabtyre cable, 0.5 m 1.640 ft long, with a round connector at the end * Use together with the optional mating cable | |||||
Cable extension | Extension up to total 100 m 328.084 ft is possible, for both emitter and receiver, with 0.5 mm2, or more, cable. (However, the interference prevention wire can extend up to 20 m 65.617 ft between two emitters.) | |||||
Net weight (Total of emitter and receiver) | 400 g approx. | 500 g approx. | 630 g approx. | 770 g approx. | 890 g approx. | |
With spatter protection hood | 500 g approx. | 630 g approx. | 800 g approx. | 990 g approx. | 1,150 g approx. | |
Accessories | MS-NA40-1 (Sensor mounting bracket): 1 set for emitter and receiver, Adjusting screwdriver: 1 pc. |
Number of beam channels | 14 | 16 | 20 | 24 | |
---|---|---|---|---|---|
Model No. | NA40-141 | NA40-16 | NA40-20 | NA40-10 | |
With spatter protection hood | NA40-14-H | NA40-16-H | NA40-20-H | NA40-10-H | |
Sensing height | 520 mm 20.472 in | 600 mm 23.622 in | 760 mm 29.921 in | 920 mm 36.220 in | |
Sensing range | 5 m 16.404 ft | ||||
Beam pitch | 40 mm 1.575 in | ||||
Sensing object | ø60 mm ø2.362 in or more opaque object | ||||
Supply voltage | 12 to 24 V DC ±10 % Ripple P-P 10 % or less | ||||
Current consumption | Emitter: 35 mA or less, Receiver: 90 mA or less | Emitter: 35 mA or less, Receiver: 115 mA or less | |||
Sensing output | NPN open-collector transistor • Maximum sink current: 100 mA • Applied voltage: 30 V DC or less (between sensing output and 0 V) • Residual voltage: 1.6 V or less (at 100 mA sink current) | ||||
Output operation | ON when all beam channels are received / OFF when one or more beam channels are interrupted | ||||
Short-circuit protection | Incorporated | ||||
Self-diagnosis output | NPN open-collector transistor • Maximum sink current: 50 mA • Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V) • Residual voltage: 1.6 V or less (at 50 mA sink current) | ||||
Output operation | OFF when unstable light received condition continues for 5 sec. or more, or the output transistor fails | ||||
Short-circuit protection | Incorporated | ||||
Response time | 12 ms or less | ||||
Indicator | Incorporated with the three color indicators on the receiver • Sensing output operation indicator: Red LED (lights up when one or more beam channels are interrupted) • Stable incident beam indicator: Green LED (lights up when all beam channels are received stably) • Unstable incident beam indicator: Yellow LED (lights up when one or more beam channels are received unstably) * When the output transistor fails, the three color indicators blink simultaneously. | ||||
Interference prevention function | Incorporated (Two units of sensors can be mounted close together.) | ||||
Protection | IP65 (IEC) | ||||
Ambient temperature | –10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage: –10 to +60 ℃ +14 to +140 ℉ | ||||
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | ||||
Ambient illuminance | Incandescent light: 3,500 ℓx or less at the light-receiving face | ||||
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure | ||||
Insulation resistance | 20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure | ||||
Vibration resistance | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | ||||
Shock resistance | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each | ||||
Emitting element | Infrared LED (synchronized scanning system) | ||||
Material | Protection enclosure: Aluminum, Unit case: ABS, Front cover: Acrylic, Lens: Acrylic | ||||
Cable | 0.5 mm2 4-core (emitter: 3-core) cabtyre cable, 0.5 m 1.640 ft long, with a round connector at the end * Use together with the optional mating cable | ||||
Cable extension | Extension up to total 100 m 328.084 ft is possible, for both emitter and receiver, with 0.5 mm2, or more, cable. (However, the interference prevention wire can extend up to 20 m 65.617 ft between two emitters.) | ||||
Net weight (Total of emitter and receiver) | 1,020 g approx. | 1,150 g approx. | 1,400 g approx. | 1,660 g approx. | |
With spatter protection hood | 1,330 g approx. | 1,500 g approx. | 1,840 g approx. | 2,190 g approx. | |
Accessories | MS-NA40-1 (Sensor mounting bracket): 1 set for emitter and receiver, Adjusting screwdriver: 1 pc. |
Note :
Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.
------------------------------ Tab3 showing ------------------------------
Dimensions
- Unit: mm in
NA40-□
Sensor
Model No. | A | B | C |
---|---|---|---|
NA40-4 | 120 4.724 | 163 6.417 | 180 7.087 |
NA40-6 | 200 7.874 | 233 9.173 | 250 9.843 |
NA40-8 | 280 11.024 | 313 12.323 | 330 12.992 |
NA40-10 | 360 14.173 | 393 15.472 | 410 16.142 |
NA40-12 | 440 17.323 | 473 18.622 | 490 19.291 |
NA40-14 | 520 20.472 | 553 21.772 | 570 22.441 |
NA40-16 | 600 23.622 | 633 24.921 | 650 25.591 |
NA40-20 | 760 29.921 | 793 31.220 | 810 31.890 |
NA40-24 | 920 36.220 | 953 37.520 | 970 38.189 |
NA40-□-H
Sensor
Model No. | A | B | C |
---|---|---|---|
NA40-4-H | 120 4.724 | 163 6.417 | 180 7.087 |
NA40-6-H | 200 7.874 | 233 9.173 | 250 9.843 |
NA40-8-H | 280 11.024 | 313 12.323 | 330 12.992 |
NA40-10-H | 360 14.173 | 393 15.472 | 410 16.142 |
NA40-12-H | 440 17.323 | 473 18.622 | 490 19.291 |
NA40-14-H | 520 20.472 | 553 21.772 | 570 22.441 |
NA40-16-H | 600 23.622 | 633 24.921 | 650 25.591 |
NA40-20-H | 760 29.921 | 793 31.220 | 810 31.890 |
NA40-24-H | 920 36.220 | 953 37.520 | 970 38.189 |
MS-NA40-1
Sensor mounting bracket (Accessory)
Material:Cold rolled carbon steel (SPCC) (Uni-chrome plated)
Four bracket set
[4 pcs. each of M5 (length 40 mm1.575 in) truss head screws, nuts and spring washers are attached.]
Assembly dimensions
Mounting drawing with NA40-□.
The assembly for the spatter protection hood type (NA40-□-H) is similar.
Model No. | A | D | E |
---|---|---|---|
NA40-4(-H) | 120 4.724 | 200 7.874 | 210 8.268 |
NA40-6(-H) | 200 7.874 | 270 10.630 | 280 11.024 |
NA40-8(-H) | 280 11.024 | 350 13.780 | 360 14.173 |
NA40-10(-H) | 360 14.173 | 430 16.929 | 440 17.323 |
NA40-12(-H) | 440 17.323 | 510 20.079 | 520 20.472 |
NA40-14(-H) | 520 20.472 | 590 23.228 | 600 23.622 |
NA40-16(-H) | 600 23.622 | 670 26.378 | 680 26.772 |
NA40-20(-H) | 760 29.921 | 830 32.677 | 840 33.071 |
NA40-24(-H) | 920 36.220 | 990 38.976 | 1,000 39.370 |
SF-IND
Large indicator for area sensor (Optional)
Assembly dimensions
Mounting drawing with NA40-□.
The assembly for the spatter protection hood type (NA40-□-H) is similar.
Model No. | E | F |
---|---|---|
NA40-4(-H) | 210 8.268 | 223 8.780 |
NA40-6(-H) | 280 11.024 | 293 11.535 |
NA40-8(-H) | 360 14.173 | 373 14.685 |
NA40-10(-H) | 440 17.323 | 453 17.835 |
NA40-12(-H) | 520 20.472 | 533 20.984 |
NA40-14(-H) | 600 23.622 | 613 24.134 |
NA40-16(-H) | 680 26.772 | 693 27.283 |
NA40-20(-H) | 840 33.071 | 853 33.583 |
NA40-24(-H) | 1,000 39.370 | 1,013 39.882 |
------------------------------ Tab4 showing ------------------------------
I/O Circuit and Wiring diagrams
I/O circuit diagrams
Notes:
1)If the interference prevention wires (orange/violet) are not used, please insulate them.
2)Never connect the emitter's interference prevention wire (orange/violet) to the receiver's self-diagnosis output (orange).This can cause damage.
Connector pin position
------------------------------ Tab5 showing ------------------------------
Cautions For Use
- Never use this product as a sensing device for personnel protection.
- For sensing devices to be used as safety devices for press machines or forpersonnel protection, use products which meet standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country.
- If this product is used as a sensing device for personnel protection, death or serious body injury could result.
- For a product which meets safety standards, use the safety light curtains.
Setting of interference prevention function
- Make sure that the power supply is off while operating the frequency selection switch. If the switch is operated while the power is on, the sensor may go into the operation stopped state. However, to restart the sensor, turn the power off and on again.
- The frequency selection switch should not be set to the positions other than those specified below.
- When the sensor A breaks down due to any reason, the sensor B goes into the operation stopped state. In order to check the operation of the sensor B, set the frequency selection switch to "1". Note that when only the sensor B breaks down, the sensor A keeps operation correctly.
When using one set of sensor
- Set the switches of both the emitter and the receiver at "1". The sensor does not function normally at other settings.
When using two sets of sensor
- Up to two sets of sensors can be mounted close together by using the interference prevention function. Set the interference prevention function in the following procedure.
Set the frequency selection switch. Firstly, push up the front cover while pressing the cover stopper towards the arrow shown in the right figure.
(2)
Turn the frequency selection switch with the accessory adjusting screwdriver to select the frequency.
Set the switches of both the emitter and the receiver of Sensor A at "1", and both switches of Sensor B at "2". The sensors do not function normally at other settings.
(3)
Connect the interference prevention wire (INTER LOCK) of Sensor A and B.
Connect both the 0 V wires in common.
+V wires need not be connected in common.
Note:
Total of wire length between Sensor A and B is 20 m 65.617 ft max.