DP-002|Digital Pressure Sensor [For Gas] DP-0
Download

*Photo may vary from actual product.
This product has been confirmed that it does not contain the 6 substances specified in EU RoHS Directive 2011/65/EU and the 4 substances specified in 2015/863/EU.
Product Number | DP-002 |
---|---|
Part Number | DP-002 |
Product | Digital Pressure Sensor |
Details | For gas |
Product Name | Digital Pressure Sensor [For Gas] DP-0 |
*Specifications and design of the products are subject to change without notice for the product improvement.
Spec Detail
Specifications and design of the products are subject to change without notice for the product improvement.
Item | Specifications |
---|---|
Part Number | DP-002 |
Product Number | DP-002 |
Products Name | Digital Pressure Sensor |
Product details | For gas |
Applicable regulations | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) |
Type of pressure | Gauge pressure |
Rated pressure range | 0.000 to +1.000 Mpa |
Set pressure range | -0.010 to +1.010 MPa -0.1 to +10.30 kgf/cm2 -0.1 to + 10.10 bar -0.1 to +146.5 psi |
Pressure withstandability | 1.5 MPa |
Applicable fluid | Air, non-corrosive gas |
Selectable units | MPa, kgf/cm2, bar, psi |
Supply voltage | 12 to 24 V DC ±10 % Ripple P-P 10 % or less |
Power consumption | 30 mA or less |
Comparative output | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between comparative output and 0 V) - Residual voltage: 2 V or less (at 50 mA sink current) |
Comparative output : Output operation | Selectable either NO or NC by key operation |
Comparative output : Hysteresis | Minimum 2 digits (variable) |
Comparative output : Repeatability | ±0.4 % F.S. (within ±4 digits) |
Comparative output : Response time | 2.5 ms, 25 ms, 250 ms, selectable by key operation |
Comparative output : Short-circuit protection | Incorporated |
Display | 3 + 1/2 digits, 3-color (white / red / pink) LCD display (Display update period: 250 ms) |
Display : Displayable pressure range | -0.010 to +1.010 MPa -0.1 to +10.30 kgf/cm2 -0.1 to + 10.10 bar -0.1 to +146.5 psi |
Protection | IP40 (IEC) |
Ambient temperature | 0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -10 to +60 ℃ +14 to +140 ℉ |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Voltage withstandability | 500 V AC for one min. between all supply terminals connected together and enclosure |
Insulation resistance | 50 MΩ or more with 500 V DC megger between all supply terminals connected together and enclosure |
Vibration resistance | 10 to 150 Hz frequency, 0.75 mm double amplitude 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each |
Shock resistance | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each |
Pollution degree | 2 |
Overvoltage category | I |
Usable altitude | 2,000 m 6,562 ft or less |
Temperature characteristics(+20℃ standard) | +10 to +40℃ +50 to +104 ℉: Within ±2 % F.S. 0 to +50℃ 32 to +122℉: Within ±5 % F.S. |
Grounding method | Floating |
Pressure port | M5 female thread |
Material | Enclosure: PBT (glass fiber reinforced) LCD display: Acrylic Pressure port: Brass (nickel plated) Mounting threaded part: Brass O-ring: Nitrile rubber (NBR) Key section: Polycarbonate |
Weight | 25 g approx. |
Accessories | CN-14A-C2 (Connector attached cable 2 m 6.562 ft) : 1 pc. |
Remark | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉. |