Item | Specifications |
---|---|
Part Number | HL-C1C-M |
Product Number | HL-C1C-M |
Products Name | Ultra High-speed Laser Displacement Sensor [CCD Style] |
Product details | Controller |
The price of the product | Please contact our office |
Connectale sensor head | Maximum 2 sensor heads |
Supply voltage | 24 V DC plus or minus 10 % including ripple 0.5 V (P-P) |
Current consumption | When 1 sensor is connected: 430 mA approx. When 2 sensors are connected: 550 mA approx. |
Sampling rate | Selectable from 100 micro s / 144 micro s / 200 micro s / 255 micro s / 332 micro s / 498 micro s / 1,000 micro s |
Temprerature characteristics | plus or minus 0.01 % F.S./degrees |
Analog output : Voltage | Output voltage: plus or minus 5 V/F.S. [default setting when diffuse reflective mode is selected (Note) ] Output range: -10.9 to +10.9 V Output current: Max. 2 mA, Output impedance: 50 Ohm (Note) If specular reflective mode is selected, then the default setting is plus or minus 4 V/F.S. |
Analog output : Current | Output current: 4 to 20 mA/F.S. [default setting when diffuse reflective mode is selected (Note 2)] Output range: 0 to 29.5 mA (maximum of 25 mA at max. load impedance) Load impedance: 250 Ohm or less (Note 1) The maximum analog output current will vary with load impedance. (Note 2) If specular reflective mode is selected, then the default setting is 5.6 to 18.4 mA/F.S. |
Alarm output | Photo-MOS relay - Maximum load current: 50 mA - Applied voltage: 30 V DC or less (between alarm output and COM) - ON impedance: 35 Ohm or less - Operation time: Max. 2 ms |
Alarm output : Output operation | Opened when the amount of light is excessive or insufficient. |
Alarm output : Short-circuit protection | Incorporated |
Judgment outputs (O1, O2) | Photo-MOS relay - Maximum load current: 50 mA - Applied voltage: 30 V DC or less (between judgment output and COM) - ON impedance: 35 Ohm or less - Operation time: Max. 2 ms |
Judgment outputs (O1, O2) : Utilization category | DC-12 or DC-13 |
Judgment outputs (O1, O2) : Output operation | Opened or closed when the threshold value is reached. Determined based on judgment output mode selection. (The threshold value varies with the hysteresis setting.) |
Judgment outputs (O1, O2) : Short-circuit protection | Incorporated |
Serial input / output | RS-232C |
Timing input (Laser emission) | Laser emission stops or continues when voltage (using input voltage: 12 to 24 V DC, maximum input voltage: 30 V DC) is input or there is an open circuit: determined based on input mode selection. |
Zero set ON input | Zero set: ON when voltage (using input voltage: 12 to 24 V DC, maximum input voltage: 30 V DC) is input |
Zero set OFF input | Zero set: OFF when voltage (using input voltage: 12 to 24 V DC, maximum input voltage: 30 V DC) is input |
Indicators : Laser emission | Green LED (lights up during laser emission from sensor head 1 or sensor head 2, or immediately before laser emission) |
Indicators : BRIGHT | Red LED (lights up upon disabled measurement due to excessive light at sensor head 1 or 2) |
Indicators : DARK | Red LED (lights up upon disabled measurement due to insufficient light at sensor head 1 or 2) |
Calibration : Shift | plus or minus 20.0000 mm plus or minus 0.787 in (Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface. |
Calibration : Span | 0.9000 to 1.1000 (Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface. |
Average number of samples | OFF, 2 to 32,768 times (16 steps) (Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface. |
Digital filters | High pass: OFF, 10 to 2,000 Hz (9 steps) Low pass: OFF, 10 to 2,000 Hz (9 steps) (Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface. |
Calculation functions | L plus or minus KA, L plus or minus KB, L plus or minus K (A plus or minus B) A, B: Sensor head 1, Sensor head 2 measurement values, L = plus or minus 999.9999, K = 0.0001 to 99.9999 (Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface. |
Hold functions | Selectable from NORMAL / P-P / PEAK / VALLEY (Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface. |
Environmental resistance : Ambient temperature | 0 to +50 degrees +32 to +122 degrees Fahrenheit (No dew condensation), Storage: -20 to +70 degrees -4 to +158 degrees Fahrenheit |
Environmental resistance : Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Environmental resistance : Vibration resistance | 10 to 55 Hz frequency (period: 1 min.) 0.75 mm 0.030 in amplitude in X,Y and Z directions for 30 min. each |
Environmental resistance : Shock resistance | 196 m/s2 (20 G approx.) in X, Y and Z directions for 3 times each |
Cable length | Power line: Less than 10 m 32.808 ft Signal line: Less than 30 m 98.425 ft |
Weight | Net weight: 300 g approx. |
Accessory | - |