HG-S1010-AC|Contact-Type Digital Displacement Sensor HG-S
Download
*Photo may vary from actual product.
This product has been confirmed that it does not contain the 6 substances specified in EU RoHS Directive 2011/65/EU and the 4 substances specified in 2015/863/EU.
Product Number | HG-S1010-AC |
---|---|
Part Number | HG-S1010-AC |
Product | Contact-Type Digital Displacement Sensor |
Details | Air-driven type |
Product Name | Contact-Type Digital Displacement Sensor HG-S |
*Specifications and design of the products are subject to change without notice for the product improvement.
Spec Detail
Specifications and design of the products are subject to change without notice for the product improvement.
Item | Specifications |
---|---|
Part Number | HG-S1010-AC |
Product Number | HG-S1010-AC |
Products Name | Contact-Type Digital Displacement Sensor |
Product details | Air-driven type 10 mm 0.394 in type General purpose |
Regulatory compliance | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) |
Applicable controller | HG-SC101(-P), HG-SC111(-P), HG-SC112(-P), HG-SC113 (Note) : Be sure to use the sensor in combination with an HG-SC□ controller manufactured in or after February 2019. |
Position detection method | Optical absolute linear encoder method |
Measurement range | 10 mm 0.394 in (Note) : The position that represents "0" as an absolute value is a position where the spindle is pushed further down from the bottom dead point by 0.1 mm 0.004 in or more. The term "stroke" indicates the total stroke length from the bottom dead point to the top dead point. |
Stroke | 10.5 mm 0.413 in or more (Note) : The position that represents "0" as an absolute value is a position where the spindle is pushed further down from the bottom dead point by 0.1 mm 0.004 in or more. The term "stroke" indicates the total stroke length from the bottom dead point to the top dead point. |
Measuring force | ・Measuring force changes with the air pressure used. Removing the seal cap enables the product to be used as the low measuring force type. ・Refer to the product page or catalog for the relationship between supplid air pressure, spindle position and the measuring force. |
Resolution | 0.5 μm 0.02 mil |
Sampling rate | 1 ms |
Indication accuracy(P-P) | Full range: 2.0 μm 0.079 mil or less Limited range: 1.0 μm 0.039 mil or less (any 60 μm 2.362 mil) |
Tip deviation amount | 35 μm 1.378 mil (typical value) |
Hot swap function | Incorporated |
Working pressure range | 0.14 to 0.16 MPa With no seal cap mounted : 0.035 to 0.045 MPa |
Capacity to resist pressure | 0.2 MPa |
Usable fluid | Clean air (Dew point temperature: -10 ℃ +14 ℉ or less) |
Applicable tube | Outside diameter: ø4 mm ø0.157 in / Inside diameter: ø2.5 mm ø0.098 in |
Operation indicator | Equipped (2-color LED: Orange / Green) |
Pollution degree | 2 |
Operating altitude | 2,000 m 6561.68 ft or less (Note) : Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m. |
Environmental resistance : Protection | IP67 (IEC) With no seal cap mounted : - (Note) : Protective structure is not applicable when the sealing portions have deteriorated or become damaged. The protection level is zero when the seal cap is removed. |
Environmental resistance : Ambient temperature | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to +140 ℉ |
Environmental resistance : Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Insulation resistance | 100 MΩ or more at 250 V DC |
Environmental resistance : Vibration resistance | 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (10 to 58 Hz), maximum acceleration 196 m/s2, (58 to 150 Hz) in X, Y, and Z directions for two hours each |
Environmental resistance : Shock resistance | 1,960 m/s2 acceleration in X, Y, and Z directions three times each |
Grounding method | Capacitor grounding |
Material | Body: Zinc, Holder: Stainless steel, Spindle: Tool steel, Probe (Note): Brass (body) / Ceramic (ball),, Air tube clamp: S60CM (Note) : The probe is also available as an option. |
Weight | Net weight: 80 g approx. |
Accessory | Sensor head fastening wrench: 1 pc., Mounting nut: 1 pc., Seal cap: 1pc, Air tube clamp: 1 pc. |
Remark | Where measurement conditions are not specified, the conditions used were as follows: standard type measurement probe (HG-SS10C), ambient temperature of +20 ℃ +68 ℉, and a clean atmosphere where water, oil, other liquids or dust does not come in contact with the equipment. |