A-TB72/72Q Flat Time Switches (Flush-Mount Type, Direct Mount Type) (Discontinued Products)
Download
-
Discontinued Products
-
Rating/ Performance
-
Dimensions
-
Cautions For Use
Ⅾiscontinued
Last time buy
June 30, 2023
We are sorry, the products have been discontinued. Please refer to the details of the discontinued products and the recommended substitutes list below.
------------------------------ Tab1 showing ------------------------------
Discontinued Products
- Notice concerning stop of sales and exports to South Korea
From June 2020, it became impossible to sell and export all time switches to South Korea.
------------------------------ Tab2 showing ------------------------------
Rating/ Performance
* Quartz power-failure compensation quartz motor type (A-TB72/72Q Flat Time Switches) have been discontinued on September 30, 2018.
Types | Drive system | AC motor type | Quartz power-failure compensation quartz motor type | |
---|---|---|---|---|
Voltage | 100V AC, 110V AC, 120V AC 200V AC, 220V AC, 240V AC | 100 to 240V AC | ||
Rating | Frequency | 50 / 60Hz (Switchable) | 50 / 60Hz (Common) | |
Power consumption | 1.5W or less | 1W or less | ||
Load | Circuit | Input / output separate circuit | ||
Manual ON / AUTO | Manual switch provided | |||
Capacity (Resistive load) | 15A 250V AC | |||
Setting | System | Built-in setting element swing type | ||
Minimum unit | 15-minute intervals | |||
Minimum range | 15 minutes | |||
No. of setting | Max. 48 (ON / OFF) | |||
Power failure compensation | - | 200 hours or more (at 25 ℃) | ||
Time accuracy | Clock accuracy | Synchronous with power supply frequency | Monthly error: Within ±15 seconds (at 25 ℃) | |
ON clock accuracy | ±5 min. (at 25 ℃), not including time synchronization errors | |||
Contact specifications | Contact arrangement | Flush mounting type: 1 Form A, Surface mounting type: 1 Form C | ||
Contact type | Solder / tab common terminal: Flush mounting type, Crimp terminal or bare wires: Surface mounting type | |||
Contact material | Silver alloy | |||
Life | Mechanical life (contact) | 105 times or more | ||
Electrical life (at rated load) | 2 x 104 times or more (ON / OFF) | |||
Electrical characteristics | Allowable operating voltage range | 85 to 115% of rated voltage | 80 to 110% of rated voltage | |
Insulation resistance (initial) | More than 100MΩ between charged and uncharged sections More than 100MΩ between contacts (at 500V DC megger) | |||
Dielectric strength (initial) | Between charged and uncharged sections: 1,500V AC/1 min. Between contacts : 1,000V AC/1 min. | |||
Surge resistance | Surge voltage 7,000V (±1.2 x 50μs one time) | |||
Noise resistance | Noise simulator 2,000V | Noise simulator 1,000V | ||
Temperature rise | 60℃ or less (at 25℃) | |||
Mechanical characteristics | Malfunctional vibration | 10 to 55Hz (amplitude: 0.3mm) for 10 minutes in each vertical, horizontal and lateral direction | ||
Destructive vibration | 16.7Hz (amplitude: 4.0mm) for 1 hour in each vertical, horizontal and lateral direction | |||
Malfunctional shock | 49m/s2 {5G} or more, 4 times in each vertical, horizontal and lateral direction | |||
Destructive shock | 490m/s2 {50G} or more, 5 times in each vertical, horizontal and lateral direction | |||
Ambient conditions | Ambient operating temperature | –10 ℃ to +50 ℃ +14 ℉ to +122 ℉ | ||
Ambient operating humidity | 45 to 85% RH (non-condensing) | |||
Weight ( ) denotes Surface mounting type | 120 g 4.23 oz (190 g 6.70 oz) | 100 g 3.53 oz (170 g 6.00 oz) |
Note :
Protective cover is provided on A-TB72.
------------------------------ Tab3 showing ------------------------------
Dimensions
- Unit: mm in
Flush mounting type
ATB71 series
Surface mounting type: M3.5
ATB712 series
Discontinued products
Flush mounting type
ATB75 series
Surface mounting type: M3.5
ATB752 series
------------------------------ Tab4 showing ------------------------------
Cautions For Use
Precautions in Using A-TB Time Switches (common)
For cautions regarding each product, please refer to the respective "Precautions in using" sections.
CAUTIONS FOR USE
- Use the time switch in ambient temperatures of -10 ℃ to +50 ℃ +14 ℉ to +122 ℉.
- Use Time Switch in ambient humidity of 85 % R.H. or less.
- Prevent using Time Switch in such places where inflammable or corrosive gas is generated, much dust exists, oil is splashed and considerable shock and vibration occur.
- Since the main body cover is made of polycarbonate resin, prevent contact with organic solvents such as methyl alcohol, benzine and thinner, or strong alkaline materials such as ammonia and caustic soda.
- External surge protection At a standard waveform the voltage of surge resistance against external surges is 4,000 V (7,000 V for Flat Time Switch), however, a surge voltage in excess of that may damage the internal circuit, therefore, please use a surge absorbing element.
- Provide chattering absorbing circuit to control the circuit in which chattering is a problem.
- Provide circuit breaker, fuse or other protective devices for the side of power supply.
- The power failure compensation function provides compensation if power is supplied continuously to the time switches. The internal battery is fully charged, but if the battery capacitance has dropped because of natural discharging, or if the battery has discharged completely, there may be times when the switch does not operate immediately when the power is turned on. If this happens, check to make sure that the clock is operating normally immediately after the power is turned on, and then set the clock to the proper time.
LIFE FOR TIME SWITCH
Item | Average life | Conditions |
---|---|---|
Contact switching times | Approx. 2 x 104 times | Resistive load 250 V AC 15 A |
Years of use (Note) | Approx. 5 years | Normal temperature (+25 ℃ +77 ℉) |
When the value on the left has been reached, we recommend replacing the product with a new one.
Note :
Average working life will decrease the higher the operating temperature gets (20,000 hours when +50 ℃ +122 ℉).
PRECAUTIONS CONCERNING WIRING
Connections should be made using wiring of Ø 1 to Ø 1.6 Ø 0.039 to Ø 0.063, or 1.25 to 2 mm2 2 to 3 x 10−3 in2, with a 600 V vinyl insulating sheath.
If connecting wires just as they are
Using crimp terminals
Use a crimp terminal with an insulating tube and an open tip (for M3.5 screws).
CONNECTION METHODS
Note :
Please remove the crossover (dotted line) connected to the electromagnetic breaker with case cover.
A-TB72/72Q Flat time switches Caution for use
A-TB72/72Q Flat Time Switches have been discontinued on September 30, 2018.
Output setting
- ON setting: Turn the setting element inward.
- OFF setting: Turn the setting element outward.
- Turn the setting element sufficiently until the click action is felt.
Clock setting
- Be sure to turn the knob at the clock center in the arrow direction to set the clock to the present time. (The dial also turns together with the clock.) Be sure to prevent reverse turning.
- Do not turn the dial to set the clock.
Attachment
- Insert Time Switch from the front of the attachment panel. (One-touch system: Flush mounting type)
- Either use 3.8 or M4 wood screws for attachment, or use DIN rails with a width of 35 mm 1.378 in (AT8-DLA1). (Surface mounting type)
Contact relay operation if the power fails (A-TB72Q Flat Time Switches [ATB75 series] * Order accepted till September, 2018)
- Contact relays remain closed while the power is off.
Power failure compensation (A-TB72Q Flat Time Switches [ATB75 series] * Order accepted till September, 2018)
- An internal secondary (Ni-NH) battery is provided to compensate for power failures, but the power supply should be left on as much as possible. Turning the power supply on and off shortens the service life of the battery.
- After continuous charging for 48 hours, the battery provides 200 hours of power failure compensation. The internal battery is fully charged, but if the battery capacitance has dropped because of natural discharging, or if the battery has discharged completely, there may be times when the switch does not operate immediately when the power is turned on. If this happens, set the clock to the proper time after the power has been back on for three to four hours.
- Secondary batteries are a valuable commodity which can be recharged. They cannot be replaced, but if being discarded after use, please make sure they are recycled if possible. When discarding the battery, turn off the power supply to Time Switches, and use radio pliers to disassemble the overall connections and remove the battery.
Precautions concerning wiring
With flush mounting types, wiring should be connected by soldering it directly, or using the #187 flat connecting element provided as an accessory.
Compliance with the CE marking
Abide by the following installation conditions and cautions in order to satisfy EN61812-1 requirements.
- Overvoltage category II,
pollution level 2 - Wiring
The voltage applied to the timer should be protected with an overcurrent protection device (example: T 1A, 250 V AC time lag fuse) that conforms to the EN/IEC standards. - Installation and removal
- Panel-mounted models are timers for installing on the surface of the control panel. Store the terminal section inside the control panel.
- Direct-mounted models are timers for installing inside the control panel. Do not touch the terminal section or other parts of the timer unit while an electric current is applied.
- Before installation or removal, confirm that there is no voltage being applied to any of the terminals.
- Do not use this timer with a safety circuit. For example, when using a timer in a heater circuit, etc., provide a protection circuit on the machine side.