KT9R Temperature Controller (Discontinued Products)
Download
-
Discontinued Products
-
Number System
-
Rating/ Performance
-
Dimensions
-
Wiring/ Connection
-
Cautions For Use
Ⅾiscontinued
Last time buy (JST)
September 29, 2023
We are sorry, the products have been discontinued. Please refer to the details of the discontinued products and the recommended substitutes list below.
------------------------------ Tab1 showing ------------------------------
Discontinued Products
------------------------------ Tab2 showing ------------------------------
Number System
------------------------------ Tab3 showing ------------------------------
Rating/ Performance
Performance outline
Item | Specifications | ||||
---|---|---|---|---|---|
CE marking directive compliance | Low Voltage Directive, EMC Directive, RoHS Directive | ||||
Size | 96×96mm 3.780 × 3.780 in | ||||
Rating | Rating power supply | 100 - 240V AC | |||
Rating frequency | 50 / 60Hz | ||||
Rating power consumption | 8 VA approx. | ||||
Rating scale | Input type | Input range | |||
Thermocouple | K | -200 to 1,370℃ (-328 to 2,489℉) | |||
-200.0 to 400.0℃ (-328.0 to 752.0℉) | |||||
J | -200 to 1,000℃ (-328 to 1,832℉) | ||||
R | 0 to 1,760℃ (0 to 3,200℉) | ||||
S | 0 to 1,760℃ (0 to 3,200℉) | ||||
B | 0 to 1,820℃ (32 to 3,308℉) | ||||
E | -200 to 800℃ (-328 to 1,472℉) | ||||
T | -200.0 to 400.0℃ (-328.0 to 752.0℉) | ||||
N | -200 to 1,300℃ (-328 to 2,372℉) | ||||
PL-II | 0 to 1,390℃ (32 to 2,534℉) | ||||
C (W / Re5−26) | 0 to 2,315℃ (32 to 4,199℉) | ||||
RTD | Pt100 | -200 to 850℃ (-328 to 1,562℉) | |||
-200.0 to 850.0℃ (-328.0 to 1,562.0℉) | |||||
JPt100 | -200 to 500℃ (-328 to 932℉) | ||||
-200 to 500.0℃ (-328.0 to 932.0℉) | |||||
DC | Current | 4 to 20 mA DC | -2,000 to 10,000 | ||
0 to 20 mA DC | |||||
Voltage | 0 to 1 V DC | ||||
0 to 10 V DC | |||||
1 to 5 V DC | |||||
0 to 5 V DC | |||||
・Scaling and change to the decimal point position is possible for DC current input and DC voltage input. ・DC current input of KT2 / KT7 / KT4H / KT4B is supported with an externally connected 50 Ω shunt resistor (sold separately). | |||||
Sensor input | Thermocouple | K, J, R, S, B, E, T, N, PL-II, C (W / Re5-26) External resistor: Max. 100 Ω (Max. 40 Ω external resistor for B input) | |||
RTD | Pt100, JPt100 3-conductor system (Allowable input conductor resistance for each conductor: 10 Ω or less) | ||||
DC current | 0 to 20 mA DC | Input impedance: 50 Ω (For KT2 / KT7 / KT4H / KT4B, connect 50 Ω shunt resistor between input terminals.) Allowable input current: 50 mA or less (For KT2 / KT7 / KT4H / KT4B, when 50 Ω shunt resistor is used) | |||
4 to 20 mA DC | |||||
DC voltage | 0 to 1 V DC | Input impedance: 1 MΩ or more, Allowable input voltage: 5 V or less, Allowable signal source resistance: 2 kΩ or less | |||
0 to 5 V DC | Input impedance: 100 kΩ or more, Allowable input voltage: 15 V or less, Allowable signal source resistance: 100 Ω or less | ||||
1 to 5 V DC | |||||
0 to 10 V DC | |||||
Control output | Relay contact | (Must be specified) | 1a | ||
3 A 250 V AC (at resistive load), 1 A 250 V AC (at inductive load cos ø = 0.4), Electrical life: 100,000 times | |||||
Non-contact voltage (voltage output for SSR drive) | 12+20 V DC, Max. load current: 40 mA (with short circuit protection circuit) | ||||
DC current | 4 to 20 mA DC, Load resistance: Max. 550 Ω | ||||
Alarm output 1 (EV1) | Relay contact 1a 3 A 250 V AC (Resistive load) 1a 1 A 250 V AC (cosø=0.4) Electrical life: 100,000 times | ||||
Alarm output 2 (EV2) | Same as Alarm output 1 | ||||
Control method | PID action (with auto-tuning function), PI action, PD action (with manual reset function), P action (with manual reset function), ON / OFF action | ||||
Target temperature setting | - | ||||
Program control function | 1 pattern, 9-step setting is possible (However, make function selection setting of either control with fixed set point or program control.) | ||||
Indication accuracy | Thermocouple | Within ± (0.2 % + 1 digit) of each input span or within ±2 ℃ (4 ℉) whichever is greater However, R or S input; within ±6 ℃ (12 ℉) in the range of 0 to 200 ℃ (32 to 392 ℉) B input, range of 0 to 300 ℃ (32 to 572 ℉): accuracy is not guaranteed. K, J, E, T, and N input, less than 0 ℃ (32 ℉): within ± (0.4 % ±1 digit) of input span | |||
RTD | Within ± (0.1 % + 1 digit) of each input span or ±1 ℃ (2 ℉) whichever is greater | ||||
DC current and DC voltage | Within ± (0.2 % + 1 digit) of each input span | ||||
Sampling period | 125ms | ||||
Hysteresis (ON / OFF) | Thermocouple and RTD: 0.1 to 1,000.0 ℃ (℉) DC current and DC voltage: 1 to 10,000 (The decimal point place follows the selection) | ||||
Proportional band | Input without decimal point: 0 to Input span Input with decimal point: 0.0 to Input span DC current and DC voltage: 0.0 to 1,000.0 % | ||||
Integral time | 0 to 3,600 seconds | ||||
Derivative time | 0 to 1,800 seconds | ||||
Proportional cycle | 1 to 120 seconds | ||||
Allowable voltage fluctuation | When 100 to 240 V AC: 85 to 264 V AC, When 24 V AC / DC: 20 to 28 V AC / DC | ||||
Insulated resistance | 500 V DC, Min. 10 MΩ | ||||
Breakdown voltage | Between input terminal and power terminal Between output terminal and power terminal 1.5 kV AC for 1 min. | ||||
Malfunction vibration | 10 to 55 Hz (1 cycle/min.), single amplitude: 0.35 mm 0.014 in (10 min. on 3 axes) | ||||
Breakdown vibration | 10 to 55 Hz (1 cycle/min.), single amplitude: 0.75 mm 0.030 in (1 hour on 3 axes) | ||||
Malfunction shock | X, Y and Z each direction for 5 times 98 m/s2 | ||||
Breakdown shock | X, Y and Z each direction for 5 times 294 m/s2 | ||||
Ambient temperature | −10 to 55 ℃ 14 to 131 ℉ | ||||
Ambient humidity | 35 to 85 % RH (No condensation) | ||||
Mass | 220 g approx. | ||||
Waterproof | IP66 (applicable only to the front panel subject to rubber gasket employed) | ||||
Display character height | PV: 14 mm 0.551 in SV: 14 mm 0.551 in | ||||
Option functions | Heating / Cooling control | Relay contact | Using EV2 assigned setting, use for heating and cooling control is possible. | ||
Non-contact voltage | - | ||||
Heater burnout alarm output | - | ||||
Communication function | - | ||||
Accessories | Installation frame / Mounting bracket | Included with controller | |||
Terminal cover | Sold separately | ||||
Rubber gasket | Included with controller |
------------------------------ Tab4 showing ------------------------------
Dimensions
- Unit: mm in
Tolerance: ±1 ±0.039
Note: Dimensions when terminal cover is fitted.
Panel cutout
Tolerance: ±1±0.039
CT1
Current transformer (CT) (for 5, 10, and 20A)
CT2
Current transformer (CT) (for 50 A)
Note:
Current transformer CT1 or CT2 is included (only with KT7 and KT4H)
when heater burnout alarm function is added.
AKT8R801 (for KT8R)
AKT9R801 (for KT9R)
Terminal cover
2 pieces of terminal cover of AKT8R801 can be used as an AKT9R801.
------------------------------ Tab5 showing ------------------------------
Wiring/ Connection
EXTERNAL CONNECTION DIAGRAM
PWR : Power supply voltage 100-240 V AC
EV1 : Alarm output 1
EV2 : Alarm output 2 (optional)
O1 : Control output 1
TC : Thermocouple input
RTD : Resistance temperature detector input
DC : DC voltage input or DC current input
------------------------------ Tab6 showing ------------------------------
Cautions For Use
Mounting
Please install to a rigid, irregularity-free flat surface in order to satisfy the IP66 specification for dust and splash proofing.
Panel thickness for installation: 1 to 7 mm 0.039 to 0.276 in.
(1)Insert the controller from the front of the control panel.
(2)Attach the screw type mounting brackets by the holes at the top and bottom of the case and secure the controller in place with the screws.
Apply tightening torque of 0.1 N•m.
Part description
Note: Color selection is the same for each size.
(1)PV display : Indicates the process value (PV). (2)SV display : Indicates the setting value (SV) (3)Increase key : Increases the numeric value (4)Decrease key : Decreases the numeric value (5)Mode key : Selects the setting mode or registers the setting value. (6)OUT / OFF key : The control output ON / OFF, auto / manual control function or program control can be switched. (7)STEP / MEMO display : Indicates the step number (program control) and set value memory number (8)Action indicators O1 : Lights up when control output 1 is ON.Lights up when heating control output (optional) is ON.
For DC power output type, it flashes corresponding to the manipulated variable in a 125 ms cycle O2 : Lights up when cooling control output (optional)
is ON. EV1 : Lights when alarm output 1 is ON. EV2 : Lights when alarm output 2 (optional) is ON. AT : Flashes during auto-tuning or auto-reset.
Notes on site selection
This controller is intended to be used in the following environment (IEC 61010-1)
Mount the controller in a place with:
- Overvoltage category II and Pollution degree 2
- A minimum of dust, and an absence of corrosive gases
- No flammable, explosive gases
- Few mechanical vibrations or shocks
- No exposure to direct sunlight, an ambient temperature of -10 to 55 ℃ 14 to 131 ℉ that does not change rapidly. (When installing inside a panel, make particular allowance for heat dissipation. Avoid installation in situations such as above equipment that generates heat.)
- Locations in which temperature rapidly changes may cause condensation.
- Locations or atmospheres in which benzine, thinners, alcohol, or other organic solvents are present, or in which ammonia, sodium hydroxide, or other strong alkaline substances may adhere.
- Locations susceptible to direct impact or the transmission of vibrations, or where splashing with water is possible.
- In the proximity of equipment in which large switching surges occur or near high-voltage cables, high-voltage equipment, power lines, power equipment, ham radio transmitters, or equipment containing these or similar devices.
- An ambient non-condensing humidity of 35 to 85 % RH
- No large capacity electromagnetic switches or cables through which large current is flowing
- No water, oil or chemicals or where the vapors of these substances can come into direct contact with the controller
Notes on wiring
Wire-pressed terminal | Company name | Type name | Fastening torque |
---|---|---|---|
Fork type | NICHIFU Co., Ltd. | 1.25Y-3 | 0.6 N•m Max. 1.0 N•m. |
J.S.T. Mfg. Co., Ltd. | VD1.25-B3A | ||
Round type | NICHIFU Co., Ltd. | 1.25-3 | |
J.S.T. Mfg. Co., Ltd. | V1.25-3 |
- The terminal block of KT4R / KT8R / KT9R / KT4H / KT4B series are designed to be wired from the left side (The terminal of KT2 series are designed to be wired from the upper and lower direction). The lead wire must be inserted from the left side of the terminal, and fastened by the terminal screw. Use a wirepressed terminal with insulation sleeve that fits to the M3 screw.
- Terminal screw fastening torque is 0.6 N·m to 1.0 N·m (for KT4R / KT8R / KT9R / KT4H / KT4B series). For KT7 series by M3 screw is less than 0.5 N·m and by M2 screw is less than 0.25 N·m respectively.
- Use a thermocouple and compensating lead wire according to the sensor input specification of the controller.
- Use a 3-wire system of RTD according to the sensor input specification of the controller.
- This controller has no built-in power switch, circuit breaker and fuse. Therefore, it is necessary to install them in the circuit near the external controller. (Recommended fuse: Time-lag fuse, rating voltage 250 V AC, rating current 2 A)
- In the case of 24 V AC / DC power supply, do not confuse the polarity when it is DC.
- With the relay contact output type, use the relay externally according to the capacity of the load to protect the built-in relay contact.
- When wiring, keep input wire (Thermocouple, RTD, etc.) away from power source wire and load wire.
- Turn the power supply to the instrument off before wiring or checking. Working or touching the terminal with the power switched on may result in electric shock which could cause severe injury or death.
- Do not drop wire chips into the holes of vent when wiring.
- To prevent the controller from harmful effects of unexpected high level noise, it is recommended that a surge absorber be installed between the electromagnetic switch coils.
Notes on mounting
- Do not use excessive force while screwing in the mounting frame and mounting bracket of KT4R / KT8R / KT9R / KT4H / KT4B series.
For KT8R / KT9R series, recommended torque is approximately 0.1 N·m.
For KT4H / KT4B series, recommended torque is approximately 0.05 to 0.06 N·m.
For KT4R series, recommended torque is approximately 0.15 N·m. - When mounting the KT7 series to the DIN rail, mount it in a lateral direction. Make sure a click is audible when fixed into place.