Power voltage Vcc | 4.5 to 15V DC |
---|
Current consumption | Max. 17mA |
---|
Output current capacity | Max. 15mA |
---|
Rise and shutdown time | Max. 1 μsec. (When Vcc = 12V Load resistance 820Ω Output cord 1.2m) |
---|
Output saturation voltage | Max. 0.4 (when output current capacity is 15mA) |
---|
Response frequency | Min. 1KHz |
---|
Standard detection electromagnet | Rare earth magnet [(BH) max. = 20MGOe] 5 dia. 2 |
---|
Detection distance | 2. 5mm .098inch |
---|
Settings distance | 0 to 2mm 0 to .079inch |
---|
Movement differential | 1. 5mm .059inch max. at set distance of 1mm .039inch. |
---|
Electromagnet polarity | Sensor detected at [N] pole. *No detection at [S] pole. |
---|
Ambient temperature | 0℃ to +55℃ +32℉ to +131℉ |
---|
Storage temperature | –10℃ to 70℃ +14℉ to +158℉ |
---|
Insulation resistance | 50MΩ (at DC 500V mega) (between lead wire and attachment board) |
---|
Voltage resistance | AC 500V 1 min. (between lead wire and attachment board) |
---|
Vibration resistance | 10 to 55Hz amplitude 1.5mm .059inch 2 hours X, Y, Z each direction |
---|
Shock absorption | 490m/s2 {50G} X, Y, Z each axis three times each |
---|